A retarding field energy analyzer designed to measure ion energy distributions impacting a radio-frequency biased electrode in a plasma discharge is examined. The analyzer is compact so that the need for differential pumping is avoided. The analyzer is designed to sit on the electrode surface, in place of the substrate, and the signal cables are fed out through the reactor side port. This prevents the need for modifications to the rf electrode—as is normally the case for analyzers built into such electrodes. The capabilities of the analyzer are demonstrated through experiments with various electrode bias conditions in an inductively coupled plasma reactor. The electrode is initially grounded and the measured distributions are validated with the Langmuir probe measurements of the plasma potential. Ion energy distributions are then given for various rf bias voltage levels, discharge pressures, rf bias frequencies—, and rf bias waveforms—sinusoidal, square, and dual frequency.
Skip Nav Destination
Article navigation
March 2008
Research Article|
March 10 2008
Retarding field analyzer for ion energy distribution measurements at a radio-frequency biased electrode
D. Gahan;
D. Gahan
a)
1National Centre for Plasma Science and Technology,
Dublin City University
, Glasnevin, Dublin 9, Ireland
Search for other works by this author on:
B. Dolinaj;
B. Dolinaj
2Impedans Ltd., Invent Centre,
Dublin City University
, Glasnevin, Dublin 9, Ireland
Search for other works by this author on:
M. B. Hopkins
M. B. Hopkins
1National Centre for Plasma Science and Technology,
Dublin City University
, Glasnevin, Dublin 9, Ireland
Search for other works by this author on:
a)
Electronic mail: [email protected].
Rev. Sci. Instrum. 79, 033502 (2008)
Article history
Received:
January 08 2008
Accepted:
February 09 2008
Citation
D. Gahan, B. Dolinaj, M. B. Hopkins; Retarding field analyzer for ion energy distribution measurements at a radio-frequency biased electrode. Rev. Sci. Instrum. 1 March 2008; 79 (3): 033502. https://doi.org/10.1063/1.2890100
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Analysis methodology of coherent oscillations in time- and angle-resolved photoemission spectroscopy
Nicolas Gauthier, Hadas Soifer, et al.
Related Content
Analysis of retarding field energy analyzer transmission by simulation of ion trajectories
Rev. Sci. Instrum. (April 2018)
Retarding field energy analyzer for high energy pulsed electron beam measurements
Rev. Sci. Instrum. (January 2017)
Novel data interpretation method for DIII-D divertor retarding field energy analyzer with 3-D particle-in-cell simulations
Rev. Sci. Instrum. (July 2024)