Radiochromic film (RCF) is increasingly being used as a detector for proton beams from short-pulse laser-matter interaction experiments using the RCF imaging spectroscope technique. The community has traditionally used inexpensive flatbed scanners to digitize and analyze the data, as opposed to more expensive and time-consuming microdensitometers (MicroDs). Often, the RCF densities in some regions exceed an optical density (OD) of 3. Flatbed scanners are generally limited to a maximum OD of . Because of the high exposure density, flatbed scanners may yield data that are not reliable due to light scatter and light diffusion from areas of low density to areas of high density. This happens even when the OD is slightly above 1. We will demonstrate the limitations of using flatbed scanners for this type of radiographic media and characterize them compared to measurements made using a MicroD. A technique for cross characterizing both systems using a diffuse densitometer with a NIST wedge will also be presented.
Skip Nav Destination
Article navigation
October 2008
Research Article|
October 31 2008
Characterization of radiochromic film scanning techniques used in short-pulse-laser ion accelerationa)
Joseph S. Cowan;
Joseph S. Cowan
Los Alamos National Laboratory
, Los Alamos, New Mexico 87545, USA
Search for other works by this author on:
Kirk A. Flippo;
Kirk A. Flippo
Los Alamos National Laboratory
, Los Alamos, New Mexico 87545, USA
Search for other works by this author on:
Sandrine A. Gaillard
Sandrine A. Gaillard
c)
Los Alamos National Laboratory
, Los Alamos, New Mexico 87545, USA
Search for other works by this author on:
Rev. Sci. Instrum. 79, 10E535 (2008)
Article history
Received:
May 15 2008
Accepted:
July 24 2008
Citation
Joseph S. Cowan, Kirk A. Flippo, Sandrine A. Gaillard; Characterization of radiochromic film scanning techniques used in short-pulse-laser ion acceleration. Rev. Sci. Instrum. 1 October 2008; 79 (10): 10E535. https://doi.org/10.1063/1.2971974
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
Optimization of radiochromic film stacks to diagnose high-flux laser-accelerated proton beams
Rev. Sci. Instrum. (September 2020)
Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability
Rev. Sci. Instrum. (July 2016)
Evaluation of the spatial resolution of Gafchromic™ HD-V2 radiochromic film characterized by the modulation transfer function
AIP Advances (August 2023)
Dosimetry evaluation of EBT3 radiochromic film based on scanning method for radiation therapy
AIP Conf. Proc. (June 2023)
Radiochromic Film Dosimetry and its Applications in Radiotherapy
AIP Conference Proceedings (May 2011)