An experimental setup has been developed to perform soft x-ray coherent scattering at beamline ID08 of the European Synchrotron Radiation Facility. An intense coherent beam was obtained by filtering the primary beam with the monochromator and a circular pinhole. A pinhole holder with motorized translations was installed inside the UHV chamber of the diffractometer. The scattered intensity was recorded in reflection geometry with a back-illuminated charge coupled device camera. As a demonstration we report experimental results of resonant magnetic scattering using coherent beam. The degree of coherence is evaluated, and it is shown that, while the vertical coherence is much higher than the horizontal one at the source, the situation is reversed at the diffractometer. The intensity of the coherent beam is also discussed.
Skip Nav Destination
Article navigation
September 2007
Research Article|
September 06 2007
Soft x-ray coherent scattering: Instrument and methods at ESRF ID08 Available to Purchase
Guillaume Beutier;
Guillaume Beutier
a)
DRFMC, SP2M,
CEA Grenoble
, 17 avenue des Martyrs, 38054 Grenoble Cedex, France
Search for other works by this author on:
Alain Marty;
Alain Marty
DRFMC, SP2M,
CEA Grenoble
, 17 avenue des Martyrs, 38054 Grenoble Cedex, France
Search for other works by this author on:
Frédéric Livet;
Frédéric Livet
LTPCM,
INPG-UJF-CNRS
, BP 75, 38402 St. Martin d’Hères, France
Search for other works by this author on:
Gerrit van der Laan;
Gerrit van der Laan
Magnetic Spectroscopy Group,
Daresbury Laboratory
, Warrington WA4 4AD, United Kingdom
Search for other works by this author on:
Stefan Stanescu;
Stefan Stanescu
b)
ESRF
, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex, France
Search for other works by this author on:
Peter Bencok
Peter Bencok
c)
ESRF
, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex, France
Search for other works by this author on:
Guillaume Beutier
a)
DRFMC, SP2M,
CEA Grenoble
, 17 avenue des Martyrs, 38054 Grenoble Cedex, France
Alain Marty
DRFMC, SP2M,
CEA Grenoble
, 17 avenue des Martyrs, 38054 Grenoble Cedex, France
Frédéric Livet
LTPCM,
INPG-UJF-CNRS
, BP 75, 38402 St. Martin d’Hères, France
Gerrit van der Laan
Magnetic Spectroscopy Group,
Daresbury Laboratory
, Warrington WA4 4AD, United Kingdom
Stefan Stanescu
b)
ESRF
, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex, France
Peter Bencok
c)
ESRF
, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex, Francea)
Present address: Diamond Light Source, Didcot OX11 0DE, United Kingdom; electronic mail: [email protected]
b)
Present address: SOLEIL, BP 48, 91192 Gif-sur-Yvette Cedex, France.
c)
Present address: Diamond Light Source, Didcot OX11 0DE, United Kingdom
Rev. Sci. Instrum. 78, 093901 (2007)
Article history
Received:
April 22 2007
Accepted:
August 13 2007
Citation
Guillaume Beutier, Alain Marty, Frédéric Livet, Gerrit van der Laan, Stefan Stanescu, Peter Bencok; Soft x-ray coherent scattering: Instrument and methods at ESRF ID08. Rev. Sci. Instrum. 1 September 2007; 78 (9): 093901. https://doi.org/10.1063/1.2779218
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Line-scan imaging for real-time phenotypic screening of C.
elegans
Aaron Au, Maximiliano Giuliani, et al.
An ion-imaging detector for high count rates
Kai Golibrzuch, Florian Nitz, et al.
Related Content
A time-of-flight–Mott apparatus for soft x-ray spin resolved photoemission on solid samples
Rev. Sci. Instrum. (March 2008)
Thin conductive diamond films as beam intensity monitors for soft x-ray beamlines
Rev. Sci. Instrum. (March 2013)
The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering
Rev. Sci. Instrum. (November 2014)
Development of the ESRF vacuum system
AIP Conf. Proc. (August 1991)
The Optics Laboratory of the ESRF (abstract)
Rev. Sci. Instrum. (January 1992)