A type of mixing flow unit for BT 2.15D SETARAM calorimeter was designed for measuring heats of mixing of two liquids or a gas and a liquid. A cooling system using a cryostat circulating a cooling agent (ethanol) through the instrument was proposed and tested for temperatures down to . In addition, a special heat exchanger was constructed for cooling down fluids entering the calorimeter when experiments are performed at subambient temperatures. In comparison with cooling by liquid nitrogen, the operation is less expensive and no tedious manipulations with liquid nitrogen are needed. A procedure for measuring with the mixing unit was developed and the assembly was successfully tested in the temperature range from and at pressures up to using several binary systems (liquid-liquid) where reliable literature data were available. The proposed flow arrangement is much more efficient and convenient to use at subambient temperatures compared to conducting experiment in a batch mode, which is the approach still prevailing at these conditions.
Skip Nav Destination
Article navigation
July 2005
Research Article|
June 27 2005
Flow unit for measuring heats of mixing at subambient conditions Available to Purchase
Miloš Poledníček;
Miloš Poledníček
a)
Laboratoire de Thermodynamique des Solutions et des Polymères,
Université Blaise Pascal Clermont-Ferrand/CNRS
, 61777 Aubière, France
Search for other works by this author on:
Vladimír Majer;
Vladimír Majer
b)
Laboratoire de Thermodynamique des Solutions et des Polymères,
Université Blaise Pascal Clermont-Ferrand/CNRS
, 61777 Aubière, France
Search for other works by this author on:
Vladimír Hynek;
Vladimír Hynek
Department of Physical Chemistry,
Institute of Chemical Technology Prague
, 16628 Prague 6, Czech Republic
Search for other works by this author on:
Jacques Jose
Jacques Jose
Laboratoire des Sciences Analytiques,
Université Claude Bernard/CNRS
, 69622 Villeurbanne, France
Search for other works by this author on:
Miloš Poledníček
a)
Laboratoire de Thermodynamique des Solutions et des Polymères,
Université Blaise Pascal Clermont-Ferrand/CNRS
, 61777 Aubière, France
Vladimír Majer
b)
Laboratoire de Thermodynamique des Solutions et des Polymères,
Université Blaise Pascal Clermont-Ferrand/CNRS
, 61777 Aubière, France
Vladimír Hynek
Department of Physical Chemistry,
Institute of Chemical Technology Prague
, 16628 Prague 6, Czech Republic
Jacques Jose
Laboratoire des Sciences Analytiques,
Université Claude Bernard/CNRS
, 69622 Villeurbanne, Francea)
Present address: RSI, Parc Technologique de Pre Milliet 38330 Montbonnot, France.
b)
Author to whom correspondence should be addressed; electronic mail: [email protected]
Rev. Sci. Instrum. 76, 074102 (2005)
Article history
Received:
February 02 2005
Accepted:
April 30 2005
Citation
Miloš Poledníček, Vladimír Majer, Vladimír Hynek, Jacques Jose; Flow unit for measuring heats of mixing at subambient conditions. Rev. Sci. Instrum. 1 July 2005; 76 (7): 074102. https://doi.org/10.1063/1.1938647
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
A low‐cost cryogenic temperature controller for a VG ESCALAB V system
J. Vac. Sci. Technol. A (October 1984)
Thermodynamics of the La‐Sr‐Cu‐O high Tc superconductors: Heat capacities of SrCuO2, Sr2CuO3, Sr14Cu24O41, and (La1−xSrx)CuO4−x (x=0.00, 0.05, 0.30, 0.5)
AIP Conf. Proc. (April 1991)
Atmospheric-pressure plasma treatment to modify hydrogen storage properties of multiwalled carbon nanotubes
Appl. Phys. Lett. (June 2005)