We describe a stable kHz rate laser ablation/desorption supersonic molecular beam source for use in kHz rate laser experiments. With the development of modern lasers that typically operate at kHz rates, a need has arisen for stable molecular beam laser ablation/desorption sources for the study of involatile species. Many biomolecules of interest cannot be brought into the gas phase without thermal decomposition by simply heating the substrate and most (especially refractory) metals have melting and boiling points that are impossible to reach with conventional ovens. The source is based upon strong nonresonant interaction of a dithering laser focus with a rotating and translating solid rod, hydrodynamic transport of the ablated/desorbed material in helium or argon, and subsequent supersonic expansion. Further design details include flexible and easy adjustment of the source for rapid prototyping and optimization for kHz rate performance. Due to the high rate of sample removal, a major concern is clogging of the nozzle and laser input channel due to both material condensation and debris formation. In order to illustrate the range of applications, we demonstrate (1) the kHz laser ablation of a high temperature refractory metal (niobium) for use in studies of metal clusters; and (2) the kHz laser desorption and jet cooling of an involatile biomolecule (the DNA base guanine) for use in spectroscopic and dynamical studies. This kHz source design has been shown to be stable for over 12 continuous hours of operation laser shots) and can be readily scaled to even higher repetition rates (>10 kHz).
Skip Nav Destination
,
,
,
,
,
,
,
,
Article navigation
November 2003
Research Article|
November 01 2003
Stable kilohertz rate molecular beam laser ablation sources Available to Purchase
Marc Smits;
Marc Smits
Laboratory for Physical Chemistry, Nieuwe Achtergracht 127-129, 1018 WS Amsterdam, The Netherlands
Search for other works by this author on:
C. A. de Lange;
C. A. de Lange
Laboratory for Physical Chemistry, Nieuwe Achtergracht 127-129, 1018 WS Amsterdam, The Netherlands
Search for other works by this author on:
Susanne Ullrich;
Susanne Ullrich
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
T. Schultz;
T. Schultz
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
M. Schmitt;
M. Schmitt
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
Jonathan G. Underwood;
Jonathan G. Underwood
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
James P. Shaffer;
James P. Shaffer
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
D. M. Rayner;
D. M. Rayner
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
Albert Stolow
Albert Stolow
Steacie Institute for Molecular Sciences, National Research Council of Canada, Ottawa, ON K1A OR6, Canada
Search for other works by this author on:
Marc Smits
C. A. de Lange
Susanne Ullrich
T. Schultz
M. Schmitt
Jonathan G. Underwood
James P. Shaffer
D. M. Rayner
Albert Stolow
Laboratory for Physical Chemistry, Nieuwe Achtergracht 127-129, 1018 WS Amsterdam, The Netherlands
Rev. Sci. Instrum. 74, 4812–4817 (2003)
Article history
Received:
June 10 2003
Accepted:
August 07 2003
Citation
Marc Smits, C. A. de Lange, Susanne Ullrich, T. Schultz, M. Schmitt, Jonathan G. Underwood, James P. Shaffer, D. M. Rayner, Albert Stolow; Stable kilohertz rate molecular beam laser ablation sources. Rev. Sci. Instrum. 1 November 2003; 74 (11): 4812–4817. https://doi.org/10.1063/1.1614879
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments
Karna A. Morey, Bryan T. Fichera, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Related Content
Kilohertz laser ablation for doping helium nanodroplets
Rev. Sci. Instrum. (October 2007)
Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface
Rev. Sci. Instrum. (September 1981)
Hyperfine Spectra of 7Li35Cl and 7Li37Cl
J. Chem. Phys. (June 1972)
Comparison of Cl 2 and F 2 based chemistries for the inductively coupled plasma etching of NiMnSb thin films
J. Vac. Sci. Technol. A (July 1999)
Role of N 2 addition on CF 4 /O 2 remote plasma chemical dry etching of polycrystalline silicon