Langmuir probes attached to the plasma facing components of fusion experiments are biased with constant or swept voltages to obtain measurements of plasma parameters such as electron temperature and density. The circuitry used must be rugged and protect the power supplies and electronics against generally harsh conditions and sudden discharge terminations, or disruptions. Modularity, ease of repair and expandability are important because short-lived radiation from neutron activation is often present after the discharges, preventing access to the circuitry. We report the implementation of modular probe circuitry featuring robust protection, remote testing and reset and easy maintenance and expandability, achieved by using DIN-rail modules.
REFERENCES
1.
2.
K. H. Finken et al., J. Nucl. Mater. 825 (1987).
3.
K. H.
Dippel
et al., Plasma Phys. Controlled Nucl. Fusion Res.
1
, 453
(1988
).4.
5.
R. Doerner et al., J. Nucl. Mater. 954 (1990).
6.
R. W. Conn et al., Fusion Eng. Des. 251 (1990).
7.
W. J. Corbett et al., Nucl. Fusion 1067 (1991).
8.
9.
10.
D. M. Goebel et al., J. Nucl. Mater. 115 (1989).
11.
K. H. Finken et al., Nucl. Fusion 915 (1992).
12.
P. C.
Stangeby
, J. Nucl. Mater.
145–147
, 105
(1987
).13.
W. J. Corbett et al., J. Nucl. Mater. 221 (1989).
This content is only available via PDF.
© 2001 American Institute of Physics.
2001
American Institute of Physics
You do not currently have access to this content.