Preliminary results of a feasibility study of a laser tangential viewing polarimeter for measuring electron density profiles in ITER are reported. For ITER plasma parameters and a polarimeter wavelength of 10.6 μm, a Faraday rotation of up to 26° is predicted. An electro-optic polarization modulation technique has been developed at ORNL. Laboratory tests of this polarimeter demonstrated a sensitivity of ⩽0.01°. Because of the similarity in the expected Faraday rotation in ITER and Alcator C-Mod, a collaboration between ORNL and the MIT Plasma Fusion Center has been undertaken to test this polarimeter system on Alcator C-Mod. A 10.6 μm polarimeter has been constructed and integrated into the existing C-Mod multichannel two-color interferometer. Detailed analyses and the preliminary results of the C-Mod measurements will be shown.
Skip Nav Destination
,
,
,
Article navigation
January 1997
Proceedings of the eleventh topical conference on high temperature plasma diagnostics
12-16 May 1996
Monterey, California (USA)
Abstract|
January 01 1997
A feasibility study of an infrared tangential viewing polarimeter for measurement of the electron density profile in ITER (abstract)
C. H. Ma;
C. H. Ma
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Search for other works by this author on:
D. P. Hutchinson;
D. P. Hutchinson
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Search for other works by this author on:
R. K. Richards;
R. K. Richards
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Search for other works by this author on:
J. Irby
J. Irby
MIT Plasma Fusion Center, Cambridge, Massachusetts 02139
Search for other works by this author on:
C. H. Ma
D. P. Hutchinson
R. K. Richards
J. Irby
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831
Rev. Sci. Instrum. 68, 698 (1997)
Citation
C. H. Ma, D. P. Hutchinson, R. K. Richards, J. Irby; A feasibility study of an infrared tangential viewing polarimeter for measurement of the electron density profile in ITER (abstract). Rev. Sci. Instrum. 1 January 1997; 68 (1): 698. https://doi.org/10.1063/1.1147909
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments
Karna A. Morey, Bryan T. Fichera, et al.
Measurement setup for the characterization of integrated semiconductor circuits at cryogenic temperatures
P. J. Ritter, M.-A. Tucholke, et al.
Related Content
Identification of errors in the electron density measurements of a tangential interferometer/polarimeter system during a tokamak discharge
Rev. Sci. Instrum. (August 2012)
CO2 laser polarimeter for measurement of plasma current profile in Alcator C‐Mod
Rev. Sci. Instrum. (January 1995)
Conceptual design of the tangentially viewing combined interferometer-polarimeter for ITER density measurements
Rev. Sci. Instrum. (April 2013)
C O 2 laser polarimeter for Faraday rotation measurements in the DIII-D tokamak
Rev. Sci. Instrum. (October 2008)
Design of a dispersion interferometer combined with a polarimeter to increase the electron density measurement reliability on ITER
Rev. Sci. Instrum. (September 2016)