The construction and operation of a high‐quality factor microwave sapphire resonator transducer coupled to a 1 kHz niobium membrane acoustic oscillator are presented in this paper. A four‐stage passive vibration isolation system was included in the design to permit the measurement of the transducer’s parametric properties. The isolation system was shown to sufficiently suppress mechanical noise above 100 Hz and an upper limit to the displacement sensitivity of the transducer was measured to be 3.0±0.6×10−16 m/√Hz. The parametric behavior of the transducer with a single pump readout was measured for several transducer configurations, and the results were found to be in good agreement with theory. The measurements presented here display for the first time the complete parametric behavior in a high electrical Q system, where the transducer’s bandwidth is less than the mechanical oscillator’s frequency. The high stability and low losses of our system may allow the transducer to be configured as a back‐action evasion or quantum nondemolition device.
Skip Nav Destination
Article navigation
July 1996
Research Article|
July 01 1996
Parametric back‐action effects in a high‐Q cyrogenic sapphire transducer
B. D. Cuthbertson;
B. D. Cuthbertson
Department of Physics, The University of Western Australia, Nedlands 6907, Western Australia, Australia
Search for other works by this author on:
M. E. Tobar;
M. E. Tobar
Department of Physics, The University of Western Australia, Nedlands 6907, Western Australia, Australia
Search for other works by this author on:
E. N. Ivanov;
E. N. Ivanov
Department of Physics, The University of Western Australia, Nedlands 6907, Western Australia, Australia
Search for other works by this author on:
D. G. Blair
D. G. Blair
Department of Physics, The University of Western Australia, Nedlands 6907, Western Australia, Australia
Search for other works by this author on:
Rev. Sci. Instrum. 67, 2435–2442 (1996)
Article history
Received:
May 31 1995
Accepted:
March 26 1996
Citation
B. D. Cuthbertson, M. E. Tobar, E. N. Ivanov, D. G. Blair; Parametric back‐action effects in a high‐Q cyrogenic sapphire transducer. Rev. Sci. Instrum. 1 July 1996; 67 (7): 2435–2442. https://doi.org/10.1063/1.1147193
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00