Nonlinearities inherent in the piezoelectric actuators used in high‐resolution scanning probe microscopies limit the usefulness of the instruments for precision dimensional measurements of submicrometer to micrometer scale structures. These nonlinearities can result in images where the scale changes by over 40% from one region of the image to another. This paper describes a simple two‐axis optical beam displacement sensor that is used to accurately measure the (x,y) position of a piezoelectric tube scanner used in an atomic force microscope. This sensor has a noise level of 6.1 Årms over a frequency range of 0.5 Hz–1 kHz and a stability of about 200 Å over a 30‐min period. Two different methods were used to correct the scans: postimaging software image correction and real‐time feedback scan correction. The software method allows fast imaging and does not alter the control of the microscope, but requires postimaging image processing. It also loses some image information because of interpolation errors and the necessity of cropping the image to recover a rectangular image area. Feedback correction uses the sensor and a control system to accurately position the scanner for each data point of the image. This method eliminates the postprocessing of the images as well as interpolation errors, but limits the achievable scan speed and also adds the noise of the sensor and control system to the scan itself. Finally, both scan‐correction systems reduce imaging errors dramatically over conventional open‐loop piezoelectric scanners. Both linear and quadratic scan distortion are reduced to about 1%–2% of the image size.
Skip Nav Destination
,
Article navigation
June 1991
Research Article|
June 01 1991
Optical scan‐correction system applied to atomic force microscopy Available to Purchase
R. C. Barrett;
R. C. Barrett
Department of Applied Physics, Stanford University, Stanford, California 94305
Search for other works by this author on:
C. F. Quate
C. F. Quate
Department of Applied Physics, Stanford University, Stanford, California 94305
Search for other works by this author on:
R. C. Barrett
C. F. Quate
Department of Applied Physics, Stanford University, Stanford, California 94305
Rev. Sci. Instrum. 62, 1393–1399 (1991)
Article history
Received:
January 28 1991
Accepted:
February 27 1991
Citation
R. C. Barrett, C. F. Quate; Optical scan‐correction system applied to atomic force microscopy. Rev. Sci. Instrum. 1 June 1991; 62 (6): 1393–1399. https://doi.org/10.1063/1.1142506
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.
Related Content
Feedback based simultaneous correction of imaging artifacts due to geometrical and mechanical cross-talk and tip-sample stick in atomic force microscopy
Rev. Sci. Instrum. (October 2007)
Application of analytic scanning electron microscopy to critical dimensions metrology at nanometer scale
J. Vac. Sci. Technol. B (November 2010)
Self-sensing paper-based actuators employing ferromagnetic nanoparticles and graphite
Appl. Phys. Lett. (April 2017)
Isofocal dose based proximity effect correction tolerance to the effective process blur
J. Vac. Sci. Technol. B (November 2017)
Optical beam profile monitor and residual gas fluorescence at the relativistic heavy ion collider polarized hydrogen jet
Rev. Sci. Instrum. (October 2008)