A computer‐controlled system for time‐resolved fluorescence spectroscopy is described. The system provides the simultaneous acquisition of the fluorescence decay curve, of the time‐integrated emission spectrum, and of two time‐gated spectra. Gating within the fluorescence decay is provided by setting up windows in the output of the time‐to‐amplitude converter in single photon timing instrumentation. The gate parameters (position and width) are fully programmable. Depending on the laser source used, time resolutions between 45 and 150 ps are obtained. Therefore, in most situations no deconvolution procedures are required to elaborate the spectra. The system has been characterized with the aid of suitable test solutions. The results indicate that a correct choice of the gate parameters allows complementary information (in terms of both decay times and emission spectra) of the fluorescence parameters of molecular species in molecular systems.
Skip Nav Destination
Article navigation
October 1988
Research Article|
October 01 1988
A system for time‐resolved laser fluorescence spectroscopy with multiple picosecond gating Available to Purchase
R. Cubeddu;
R. Cubeddu
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Search for other works by this author on:
F. Docchio;
F. Docchio
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Search for other works by this author on:
W. Q. Liu;
W. Q. Liu
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Search for other works by this author on:
R. Ramponi;
R. Ramponi
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Search for other works by this author on:
P. Taroni
P. Taroni
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Search for other works by this author on:
R. Cubeddu
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
F. Docchio
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
W. Q. Liu
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
R. Ramponi
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
P. Taroni
Centro di Elettronica Quantistica e Strumentazione Elettronica del CNR. Istituto di Fisica del Politecnico, P. za L. da Vinci, 32, 20133 Milano, Italy
Rev. Sci. Instrum. 59, 2254–2259 (1988)
Article history
Received:
March 23 1988
Accepted:
May 18 1988
Citation
R. Cubeddu, F. Docchio, W. Q. Liu, R. Ramponi, P. Taroni; A system for time‐resolved laser fluorescence spectroscopy with multiple picosecond gating. Rev. Sci. Instrum. 1 October 1988; 59 (10): 2254–2259. https://doi.org/10.1063/1.1139943
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
An ion-imaging detector for high count rates
Kai Golibrzuch, Florian Nitz, et al.
Line-scan imaging for real-time phenotypic screening of C.
elegans
Aaron Au, Maximiliano Giuliani, et al.