Diagnostic instruments at the Mirror Fusion Test Facility (MFTF‐B) are operated by a distributed computer system which provides an integrated control, data acquisition, and data processing interface to the experimentalist. Instrument control settings, operator inputs, and lists of data to be acquired are combined with data acquired by instrument data recorders to be used downstream by data processing codes; data processing programs are automatically informed of operator control and setpoint actions without operator intervention. The MFTF‐B distributed computing environment permits us to take advantage of several kinds of computing equipment and commercial software. The combined diagnostic control and results presentation interface is presented to experimentalist users by a network of high‐resolution graphics workstations. Control coordination, data processing, and data base management are handled by a shared‐memory network of 32‐bit super minicomputers. Direct instrument control, data acquisition, data packaging, and instrument status monitoring are performed by a network of dedicated local control microcomputers. A description of this system and our experiences in implementing the first MFTF‐B diagnostic instrument, the magnetic field alignment diagnostic (MFA), are reported here.
Skip Nav Destination
Article navigation
August 1986
Research Article|
August 01 1986
Diagnostic control, data acquisition, and data processing at MFTF‐B (invited) Available to Purchase
George G. Preckshot
George G. Preckshot
Lawrence Livermore National Laboratory, P. O. Box 5511, L‐634, Livermore, California 94550
Search for other works by this author on:
George G. Preckshot
Lawrence Livermore National Laboratory, P. O. Box 5511, L‐634, Livermore, California 94550
Rev. Sci. Instrum. 57, 1872–1876 (1986)
Citation
George G. Preckshot; Diagnostic control, data acquisition, and data processing at MFTF‐B (invited). Rev. Sci. Instrum. 1 August 1986; 57 (8): 1872–1876. https://doi.org/10.1063/1.1139156
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Related Content
A tandem mirror in place at MFTF
Physics Today (September 1981)
The (changing) MFTF vacuum environment
J. Vac. Sci. Technol. A (April 1983)
The leak‐checking and testing of the first yin–yang magnet for the Mirror Fusion Test Facility (MFTF)
J. Vac. Sci. Technol. A (April 1983)
E parallel to B energy analyzer for measurement of end‐loss ions from the Mirror Fusion Test Facility‐B
Rev. Sci. Instrum. (May 1985)
The design, construction, and testing of the vacuum vessel for the tandem Mirror Fusion Test Facility
J. Vac. Sci. Technol. A (May 1986)