The construction of a soft flash x‐ray (FX) apparatus with a new type of FX tube for biomedical use is described. The FX apparatus may be used for condenser charging voltages of 50–90 kV and peak currents of 20–40 kA. The electric pulse width of the FX waveforms was almost constant and its value was about 0.3 μs. The effective focal spot varied according to the condenser charging voltage, the anode–cathode (A–C) distance, etc., ranging from 0.2–3.0 mm in diameter. We selected two combinations of electrodes: (a) for normal focusing and a high dose rate; (b) for fine focusing and a low dose rate. The FX intensity was determined by the condenser charging voltage and the A–C distance, while the FX quality (average spectrum distribution) was determined by the average voltage of the FX tube and insertion of metal filters. The average voltage of the FX tube varied according to the condenser charging voltage and the A–C gap impedance. Various clear FX images were obtained by controlling the FX intensity, quality, and the focal spot size. We used Fuji Computed Radiography (FCR) in conjunction with our FX radiography, and by controlling the FX quality and the focal spot size, we obtained some interesting biomedical radiograms.
Skip Nav Destination
,
,
Article navigation
July 1986
Research Article|
July 01 1986
High‐intensity flash x‐ray apparatus for biomedical radiography Available to Purchase
E. Sato;
E. Sato
Department of Physics, School of General Education, Iwate Medical University, Morioka 020, Japan
Search for other works by this author on:
H. Isobe;
H. Isobe
Department of Physics, School of General Education, Iwate Medical University, Morioka 020, Japan
Search for other works by this author on:
F. Hoshino
F. Hoshino
Department of Radiology, School of Medicine, Tohoku University, Sendai 980, Japan
Search for other works by this author on:
E. Sato
H. Isobe
F. Hoshino
Department of Physics, School of General Education, Iwate Medical University, Morioka 020, Japan
Rev. Sci. Instrum. 57, 1399–1408 (1986)
Article history
Received:
September 24 1985
Accepted:
March 17 1986
Citation
E. Sato, H. Isobe, F. Hoshino; High‐intensity flash x‐ray apparatus for biomedical radiography. Rev. Sci. Instrum. 1 July 1986; 57 (7): 1399–1408. https://doi.org/10.1063/1.1138609
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Automated polarization rotation for multi-axis rotational-anisotropy second harmonic generation experiments
Karna A. Morey, Bryan T. Fichera, et al.
Refurbishment and commissioning of a dual-band 23/31 GHz tipping
radiometer at potential radio astronomical sites
J. Cuazoson, D. Hiriart, et al.
Related Content
Improvements in the Image Quality of Neutron Radiograms of NUR Neutron Radiography Facility by Using Several Exposure Techniques
AIP Conf. Proc. (March 2008)
Radiography of Chaotically Moving Objects
AIP Conf. Proc. (November 2007)
X-ray tomography in micro-gravity
Rev. Sci. Instrum. (October 2019)
COMPARISON OF SELECTED WELD DEFECT EXTRACTION METHODS
AIP Conf. Proc. (February 2008)
Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening
Rev. Sci. Instrum. (August 2024)