In order to measure respiration rates in rats irradiated to the whole thorax, a plethysmograph involving a microphone with extended low‐frequency response and an airtight, whole‐body chamber has been constructed. The microphone response to the respiration pressure waves created by the rats placed in the chamber is markedly greater in amplitude than the response to laboratory sounds and animal noises; thereby filtering complexities are avoided. The output from the microphone went to a frequency counter for measurement of the number of pressure waves per unit time. Control, unirradiated rats, between the ages of 3 and 18 months, demonstrated a respiration rate in the range of 130–160 breaths per minute. Rats that received thoracic radiation doses greater than 12 Gy displayed increased respiration rates and occasional abnormal respiration patterns. These results demonstrate that this whole‐body plethysmograph incorporating a sensitive microphone and simple electronics can be used for the measurement of respiration functions in rats with lung damage.
Skip Nav Destination
Article navigation
July 1984
Research Article|
July 01 1984
Simple plethysmograph for measuring respiration rates in rats with lung damage
Gene R. Feaster;
Gene R. Feaster
Radiation Biology Laboratory, Department of Radiation Therapy, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
Bruce F. Kimler;
Bruce F. Kimler
Radiation Biology Laboratory, Department of Radiation Therapy, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
Sheri D. Henderson;
Sheri D. Henderson
Radiation Biology Laboratory, Department of Radiation Therapy, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
Carl M. Mansfield
Carl M. Mansfield
Radiation Biology Laboratory, Department of Radiation Therapy, University of Kansas Medical Center, Kansas City, Kansas 66103
Search for other works by this author on:
Rev. Sci. Instrum. 55, 1058–1060 (1984)
Article history
Received:
January 30 1984
Accepted:
March 16 1984
Citation
Gene R. Feaster, Bruce F. Kimler, Sheri D. Henderson, Carl M. Mansfield; Simple plethysmograph for measuring respiration rates in rats with lung damage. Rev. Sci. Instrum. 1 July 1984; 55 (7): 1058–1060. https://doi.org/10.1063/1.1137900
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Rydberg electromagnetically induced transparency based laser lock to Zeeman sublevels with 0.6 GHz scanning range
Alexey Vylegzhanin, Síle Nic Chormaic, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
The whole body plethysmograph in speech research
J. Acoust. Soc. Am. (April 1993)
Comparison of tidal breathing and reiterant speech breathing using whole body plethysmography
J Acoust Soc Am (October 2014)
Comparison between Spontaneous Low‐Frequency Oscillations in Regional Cerebral Blood Volume, and Cerebral and Plethysmographic Pulsations
AIP Conference Proceedings (July 2007)
Acoustic calibrator for plethysmographic surface pressure sensors
J. Acoust. Soc. Am. (April 1993)
Acoustic and aerodynamic correlates of Hindi stops
J Acoust Soc Am (August 2005)