The design, construction, and evaluation of a computer‐controlled electronic cell sorting device is described; the computer performs all cell data analysis and sorting functions. The primary advantage is that the functions are programmable and, hence, any data analysis or sorting format can be implemented (within the constraints of the physical system). The software that has been developed is highly modular and can be manipulated to perform different functions. In our present configuration, the device analyzes data from each cell on a cell‐by‐cell basis, performs the sorting function, stores the cell data for off‐line analysis, and provides a real‐time display (histogram) of cell data.

1.
M. D.
Fulwyer
,
Science
150
,
910
(
1965
).
2.
M. R. Melamed, P. F. Mullaney, and M. L. Mendelsohn, Flow Cytometry and Sorting (Wiley, New York, 1979).
3.
P. J.
Crossland‐Taylor
,
Nature
171
,
37
(
1953
).
4.
W. H.
Coulter
,
Proc. Natl. Electron. Conf.
12
,
1034
(
1956
).
5.
H. E.
Kubitschek
,
Nature
182
,
234
(
1958
).
6.
L. L. Wheeless, in The Automation of Uterine Cancer Cytology, edited by G. F. Wied, G. F. Bahr, and P. H. Bartels (Tutorials of Cytology, Chicago, IL, 1976), p. 122.
7.
L. A.
Kamentsky
,
M. R.
Melamed
, and
H.
Derman
,
Science
150
,
630
(
1965
).
8.
D. M.
Holm
and
L. S.
Cram
,
Exp. Cell Res.
80
,
105
(
1973
).
9.
M. A.
Van Dilla
,
T. T.
Trujillo
,
P. F.
Mullaney
, and
J. R.
Coulter
,
Science
163
,
1213
(
1969
).
10.
C. V. Boys, Soap Bubbles (Dover, New York, 1959), p. 78.
11.
R. G.
Sweet
,
Rev. Sci. Instrum.
36
,
131
(
1965
).
12.
D. J.
Arndt‐Jovin
and
T. M.
Jovin
,
J. Histochem. Cytochem.
22
,
622
(
1974
).
13.
H. W.
Tyrer
,
N. J.
Pressman
, and
J. K.
Frost
,
Proc IEEE
67
,
1083
(
1979
).
14.
H. W.
Tyrer
,
Basic Appl. Histochem.
24
(
4
),
248
(
1980
).
15.
H. W.
Tyrer
,
Cytometry
2
,
132
(
1981
).
16.
G. C.
Salzman
,
R. D.
Hiebert
, and
J. M.
Crowell
,
Comput. Biomed. Res.
11
,
77
(
1978
).
17.
G. C.
Salzman
,
S. F.
Wilkins
, and
J. A.
Whitfill
,
Cytometry
1
,
325
(
1981
).
18.
R. D.
Hiebert
,
J. H.
Jett
, and
G. C.
Salzman
,
Cytometry
1
,
337
(
1981
).
19.
Becton‐Dickinson FACS Division, Sunnyvale, CA.
20.
Digital Equipment Co., Maynard, MA.
21.
J. K.
Frost
,
H. W.
Tyrer
,
N. J.
Presssman
,
C. D.
Albright
,
M. H.
Vansickel
, and
G. W.
Gill
,
J. Histochem. Cytochem.
27
,
545
(
1979
).
22.
A.
Krishan
,
J. Cell Biol.
66
,
188
(
1975
).
23.
Mean ± standard deviation.
This content is only available via PDF.
You do not currently have access to this content.