A matched, slow wave transmission line is used as a current probe. It provides a linear response, fast rise time (τr <2 ns) and high‐voltage gain (≂1 V/A) for current pulses up to microsecond duration.

1.
J.
Cooper
,
Plasma Phys.
5
,
285
(
1963
).
2.
D. G.
Pellinen
,
M. S.
Di Capua
,
S. E.
Sampayan
,
H.
Gerbracht
, and
M.
Wing
,
Rev. Sci. Instrum.
51
,
1535
(
1980
).
3.
W.
Stygar
and
G.
Gerdin
,
IEEE Trans. Plasma Sci.
PS‐10
,
40
(
1982
).
4.
Marco S. Di Capua, in Measurements of Electrical Quantities in Pulse Power Systems, edited by R. H. McKnight and R. E. Hebner (NBS, Colorado, 1982), p. 175.
5.
H. Harjes, J. Doggett, J. Gahl, K. Zinsmeyer, H. Krompholz, K. Schoenbach, G. Schaefer, and M. Kristiansen, Proceedings of the 4th Pulsed Power Conference (Albuquerque, NM 1983), Paper 20.4 (to be published).
6.
D. A. Watkins, Topics in Electromagnetic Theory (Wiley, New York, 1958), p. 65.
This content is only available via PDF.