This paper investigates the long‐term stability of three different types of thermistor with room‐temperature resistances ranging from 80 to 150 kΩ. Precision measurements of thermistor resistance and temperature were made in a thermal environment controlled to ±3 μK. Measurements took place in between periods of limited thermal cycling and also during 100 days at constant temperature. Mechanical shock and strain appear to be the cause of the high drift rates observed in some thermistors; the majority of the thermistors were, however, very stable, with drift rates around 0.1 mK per 100 days and were unaffected by thermal cycling. Such low drift rates indicate that certain thermistors could be used as convenient temperature transfer standards with a reproducibility in the submillikelvin range.

1.
G.
Bosson
,
F.
Gutmann
, and
L. M.
Simmons
,
J. Appl. Phys.
21
,
1267
(
1950
).
2.
J. S.
Steinhart
and
S. R.
Hart
,
Deep Sea Res.
15
,
497
(
1968
).
3.
Bulletin V477, Victor Engineering Corporation, Springfield, NJ.
4.
M. J.
Buckingham
,
C.
Edwards
, and
J. A.
Lipa
,
Rev. Sci. Instrum.
44
,
1167
(
1973
).
5.
D.
Sarid
and
D. S.
Cannell
,
Rev. Sci. Instrum.
45
,
1082
(
1974
).
6.
J.
Dratler
,
Rev. Sci. Instrum.
45
,
1435
(
1974
).
7.
P. H.
Sydenham
and
G. C.
Collins
,
J. Phys. E
8
,
311
(
1975
).
8.
Z.
Priel
,
J. Phys. E
11
,
27
(
1978
).
9.
M.
Grubic
and
U.
Wurz
,
J. Phys. E
11
,
692
(
1978
).
10.
B. J.
Thijsse
,
J. Chem. Phys.
74
,
4678
(
1981
).
11.
A. L. Cummings and R. J. Hocken, Rev. Sci. Instrum. (to be published).
12.
H. W. Trolander, C. A. Case, and R. W. Harruff, Temperature, Its Measurement and Control in Science and Industry, Vol. 4 (Instrument Society of America, Pittsburgh, 1972), Part 2, p. 997.
13.
S. D.
Wood
,
B. W.
Mangum
,
J. J.
Filliben
, and
S. B.
Tillett
,
J. Res. Natl. Bur. Stand.
83
,
247
(
1978
).
14.
J. A.
Lipa
,
C.
Edwards
, and
M. J.
Buckingham
,
Phys. Rev. A
15
,
778
(
1977
).
15.
Victory Engineering Corporation, type 52A62; Gulton Industries, type 51CA3; ITT, type M15.
16.
H. S. Carslaw and J. C. Jaeger, Conduction of Heat in Solids 2nd ed. (Oxford, London, 1959), pp. 20, 135.
17.
If indeed mechanical shock is implicated as suggested, manufacturers would be advised to pay greater attention to the protective packaging of the thermistors, as the distribution chain from manufacturer to consumer can be very long and the themistors are exposed to careless handling by nontechnical personnel. The packaging used by Gulton Industries for its microbead thermistors (the microbead is sandwiched between tissue pads inside a rigid cardboard pill box) appears to be suitable protection.
This content is only available via PDF.
You do not currently have access to this content.