A technique is described for reducing the size of aerosol droplets produced by a pneumatic nebulizer of the kind commonly used in flame or plasma spectrometry. The technique involves the application of an electric field to the tip of the nebulizer, resulting in an induced surface charge on the liquid being nebulized. In turn, the surface charge reduces the liquid’s surface tension and results in the generation of a finer aerosol. In this study, the effect of the electric field is quantified in terms of the spatial dispersion and size distribution of aerosol droplets formed in the presence and absence of the field. Droplet size distributions, obtained using the MgO impression technique and analyzed using log‐normal and upper‐limit functions, reveal a 63% decrease in the volume mean droplet diameter in the field’s presence. As a result, this system is expected to be useful in both flame and plasma spectrometry, where reduced droplet size can yield improved precision and freedom from interferences.
Skip Nav Destination
Article navigation
October 1978
Research Article|
August 08 2008
Enhancement of pneumatic nebulization efficiency through application of an electric field
R. N. Savage;
R. N. Savage
Department of Chemistry, Indiana University, Bloomington, Indiana 47401
Search for other works by this author on:
G. M. Hieftje
G. M. Hieftje
Department of Chemistry, Indiana University, Bloomington, Indiana 47401
Search for other works by this author on:
Rev Sci Instrum 49, 1418–1424 (1978)
Citation
R. N. Savage, G. M. Hieftje; Enhancement of pneumatic nebulization efficiency through application of an electric field. Rev Sci Instrum 1 October 1978; 49 (10): 1418–1424. https://doi.org/10.1063/1.1135281
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Captcha Validation Error. Please try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
Comparison of size distribution of polystyrene spheres produced by pneumatic and electrospray nebulization
AIP Conference Proceedings (January 2001)
Aerosol generation system for development and calibration of laser-induced breakdown spectroscopy instrumentation
Rev Sci Instrum (September 2001)
An improved ultrasonic nebulizer system for the generation of high density aerosol dispersions
Rev Sci Instrum (November 2003)
Portable acoustofluidic nebulizer
J Acoust Soc Am (October 2019)
Pulmonary monoclonal antibody delivery via a portable microfluidic nebulization platform
Biomicrofluidics (April 2015)