A new flow‐system instrument for quantitative analysis and sorting of microscopic particles, particularly biological cells, based on multiple measurements of physical and biochemical properties has been developed. Cells stained with fluorescent dyes in liquid suspension enter a unique flow chamber where electrical and optical sensors measure cell volume, single‐ or two‐color fluorescence, and light scatter, and emerge in a liquid jet that is broken into uniform droplets. Sensor signals are electronically processed several ways for optimum cell discrimination and are displayed as pulse‐amplitude distributions using a pulse‐height analyzer. Processed signals trigger cell sorting according to preselected parametric criteria. Sorting is accomplished by electrically charging droplets containing the cells and electrostatically deflecting them into collection vessels. This instrument is described in detail with illustrative examples of experiments using polystyrene fluorescent microspheres, cultured human cells, and human leukocytes.

1.
L. R.
Adams
and
L. A.
Kamentsky
,
Acta Cytol.
15
,
289
(
1971
).
2.
M. R.
Melamed
,
L. R.
Adams
,
F.
Traganos
,
A.
Zimring
, and
L. A.
Kamentsky
,
Cancer
29
,
1361
(
1972
).
3.
M. H.
Julius
,
T.
Masuda
, and
L. A.
Herzenberg
,
Proc. Natl Acad. Sci. USA
69
,
1934
(
1972
).
4.
M. R. Raju, T. T. Trujillo, P. F. Mullaney, J. A. Steinkamp, and R. A. Walters, Br. J. Radiol. (to be published).
5.
M. J. Fulwyler, J. A. Steinkamp, and J. R. Coulter, Patent No. 3 710 933 (1973), title assigned to the U.S. Atomic Energy Commission.
6.
W. H.
Coulter
,
Proc. Natl. Electron. Conf.
12
,
1034
(
1956
);
U.S. Patent No. 2 656 508 (1953).
7.
J. T.
Merrill
,
N.
Veizades
,
H. R.
Hulett
,
P. L.
Wolf
, and
L. A.
Herzenberg
,
Rev. Sci. Instrum.
42
,
1157
(
1971
).
8.
M. A.
Van Dilla
,
T. T.
Trujillo
,
P. F.
Mullaney
, and
J. R.
Coulter
,
Science
163
,
1213
(
1969
).
9.
P. F.
Mullaney
,
M. A.
Van Dilla
,
J. R.
Coulter
, and
P. N.
Dean
,
Rev. Sci Instrum.
40
,
1029
(
1969
).
10.
L. A.
Kamentsky
,
M. R.
Melamed
, and
H.
Derman
,
Science
150
,
630
(
1965
).
11.
Cytographic Analysis (Biophysics Systems, Mahopac, N.Y., 1971).
12.
P. F. Mullaney and W. T. West, Brit. J. Phys. E, 1973 (to be published).
13.
M. J.
Fulwyler
,
Science
150
,
910
(
1965
).
14.
M. J.
Fulwyler
,
R. B.
Glascock
,
R. D.
Hiebert
, and
N. M.
Johnson
,
Rev. Sci. Instrum.
40
,
42
(
1969
).
15.
H. R.
Hulett
,
W. A.
Bonner
,
J.
Barrett
, and
L. A.
Herzenberg
,
Science
166
,
747
(
1969
).
16.
W. A.
Bonner
,
H. R.
Hulett
,
R. G.
Sweet
, and
L. A.
Herzenberg
,
Rev. Sci. Instrum.
43
,
404
(
1972
).
17.
L. A.
Kamentsky
and
M. R.
Melamed
,
Science
156
,
1364
(
1967
).
18.
M. J. Fulwyler, Automated Cell Identification and Cell Sorting, edited by G. L. Wied and G. F. Bahr (Academic, New York, 1970), p. 97.
19.
R. C. Leif, Automated Cell Identification and Cell Sorting, edited by G. L. Wied and G. F. Bahr (Academic, New York, 1970), p. 131.
20.
N. B.
Grover
,
J.
Naaman
,
S.
Ben‐Sasson
, and
F.
Doljanski
,
Biophys. J.
9
,
1398
(
1969
).
21.
F. Ruch, Introduction to Quantitative Cytochemistry, edited by G. L. Wied and G. F. Bahr (Academic, New York, 1970), Vol. II p. 431.
22.
P. F.
Mullaney
and
P. N.
Dean
,
Biophys. J.
10
,
764
(
1970
).
23.
A.
Brunsting
and
P. F.
Mullaney
,
J. Colloid Interface Sci.
39
,
492
(
1972
).
24.
Barium titanate disc, 1.56 cm in diam., type 5ZT‐5H, Clevite Corp.
25.
R. G.
Sweet
,
Rev. Sci. Instrum.
36
,
131
(
1964
).
26.
Multiparameter cell separator, Los Alamos Scientific Laboratory Drawing No. 2Y‐57987 (1972). (Instrumentation drawings given in Refs. 26, 28, 30, 32, 34, 35, and 38 are available from National Technical Information Service, U.S. Department of Commerce, 5285 Port Royal Road, Springfield, Va.).
27.
Sapphire‐tipped capillary, type 01030‐2B, Specialty Glass Products, Willow Grove, Pa.
28.
Model 8107 Coulter amplifier and constant current generator, Los Alamos Scientific Laboratory Drawing No. 4Y‐89805 (1972).
29.
Applications Manual for Operational Amplifiers (Philbrick‐Nexus Research, Dedham, Mass., 1969), p. 79.
30.
Two‐color fluorescence sensor, Los Alamos Scientific Laboratory Drawing No. 2Y‐51857 (1973).
31.
RCA type C7146R (developmental).
32.
Model 8103 amplifier, Los Alamos Scientific Laboratory Drawing No. 4Y‐89721 (1972).
33.
Canberra Industries, type 1415 RC amplifier.
34.
Model 8102 pulse integrator, Los Alamos Scientific Laboratory Drawing No. 4Y‐89636 (1972).
35.
Model 71 multiparameter signal processing unit, Los Alamos Scientific Laboratory Drawing No. 4Y‐89666 (1972).
36.
Northern Scientific Corp., model 636 (modified).
37.
Nuclear‐Chicago Corp. model 24‐3.
38.
Model 72 cell separation logic and charging control, Los Alamos Scientific Laboratory Drawing No. 4Y‐89810 (1973).
39.
M. J.
Fulwyler
,
J. D.
Perrings
, and
L. S.
Cram
,
Rev. Sci. Instrum.
44
,
204
(
1973
).
40.
Defined as the standard deviation divided by the mean, assuming a normal distribution, and is calculated by dividing the full width at half‐maximum by the mean channel times 1/2.35.
41.
H. A. Crissman and J. A. Steinkamp, “Rapid Simultaneous Measurement of DNA, Protein, and Cell Volume in Single Cells from Large Mammalian Cell Populations” (unpublished).
42.
A.
Howard
and
S. R.
Pelc
,
Heredity
6
,
261
(
1953
).
43.
E. C.
Anderson
,
G. I.
Bell
,
D. F.
Petersen
, and
R. A.
Tobey
,
Biophys. J.
9
,
246
(
1969
).
44.
J. A.
Steinkamp
,
A.
Romero
, and
M. A.
Van Dilla
,
Acta Cytol.
17
,
113
(
1973
).
This content is only available via PDF.
You do not currently have access to this content.