A magnetron cold cathode ion source (CCIS) has been developed for ultrahigh vacuum residual gas analysis. The purpose is to eliminate the spurious spectra produced by the conventional hot filament source and to obtain greater sensitivity. A commercial quadrupole mass analyzer was used to evaluate source performance and potential. Resolution equaled that obtained with a hot filament source, giving mass invariant peak separations, with 10% valleys, of 1.0 amu below 150 amu and 0.7 amu below 50 amu. Sensitivities exceeded those obtained with a hot filament source, operated at a 3 mA emission current, by factors of 1.5 to 4.6, depending on pressure and mass. The corresponding CCIS sensitivities, at 1‐amu peak separation, were 0.4 mA/Torr for mass 28 at 3×10−9 Torr and 1.2mA/Torr for mass 40 at 1×10−7 Torr. Experiments indicated a potential tenfold further sensitivity improvement if a quadrupole with a higher rf potential were used; by increasing quadrupole dimensions a still greater fraction of the source internal sensitivity, which is in the vicinity of 1 A/Torr, may be realized.
Skip Nav Destination
Article navigation
October 1967
Research Article|
October 01 1967
Cold Cathode Quadrupole Mass Spectrometer Available to Purchase
P. Blum;
P. Blum
National Research Corporation, Cambridge, Massachusetts 02142
Search for other works by this author on:
F. L. Torney
F. L. Torney
National Research Corporation, Cambridge, Massachusetts 02142
Search for other works by this author on:
P. Blum
National Research Corporation, Cambridge, Massachusetts 02142
F. L. Torney
National Research Corporation, Cambridge, Massachusetts 02142
Rev. Sci. Instrum. 38, 1404–1408 (1967)
Article history
Received:
November 15 1966
Citation
P. Blum, F. L. Torney; Cold Cathode Quadrupole Mass Spectrometer. Rev. Sci. Instrum. 1 October 1967; 38 (10): 1404–1408. https://doi.org/10.1063/1.1720549
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
M. L. Reinke, I. Abramovic, et al.
Controlled partial gravity platform for milligravity in drop tower experiments
Kolja Joeris, Matthias Keulen, et al.
An instrumentation guide to measuring thermal conductivity using frequency domain thermoreflectance (FDTR)
Dylan J. Kirsch, Joshua Martin, et al.
Related Content
Simulation of high current electron and ion beam dynamics for EBIS
AIP Conf. Proc. (July 2001)
EBTS: Design and experimental study
AIP Conf. Proc. (July 2001)