A calibrated model has been used to estimate the energy savings by cool roof application on buildings located in five different climatic zones. The model has been calibrated as per the measured data in a building located in Hyderabad (India), and the same has been used to project energy savings in different cities located in five different climatic zones of the country. Results show that the maximum reduction in energy consumption is observed in Mumbai (warm and humid climate), followed by Ahmedabad (hot and dry climate), Bangalore (temperate climate), and Delhi (composite climate). Least energy saving is observed in Shillong (cold climate). In all the climates except cold, the financial payback period is acceptable, being less than 3 yr, whereas for cold climate, the investment is getting paid back in 6.69 yr, making the cool roof application not very attractive.

1.
Y.
Pan
,
Z.
Huang
, and
G.
Wu
,
Energy Build.
39
,
651
(
2007
).
2.
M. J.
Chimack
,
Proceedings of the Seventh International IBPSA Conference
,
2001
, pp.
191
197
.
3.
A.
Pedrini
,
F. S.
Westphal
, and
R.
Lamberts
,
Build. Environ.
37
,
903
(
2002
).
4.
J.
Yoon
,
D. E.
Claridge
, and
E. J.
Lee
,
J. Sol. Energy Eng.
125
,
251
(
2003
).
5.
J. S.
Haberl
and
T. E.
Bou-Saada
,
J. Sol. Energy Eng.
120
,
193
(
1998
).
6.
H.
Akbari
,
R.
Levinson
, and
L.
Rainer
,
Energy Build.
37
,
1007
(
2005
).
7.
S.
Konopacki
,
H.
Akbari
,
M.
Pomerantz
,
S.
Gabersek
, and
L.
Gartland
, “
Cooling energy saving potential of light-colored roof for residential and commercial buildings in 11 US metropolitan cities
,”
Lawrence Berkeley National Laboratory
Report No. LBNL-39433,
1997
.
8.
S.
Konopacki
,
L.
Gartland
,
H.
Akbari
, and
L.
Rainer
, “
Demonstration of energy savings of cool roofs
,”
Lawrence Berkeley National Laboratory
Report No. LBNL-40673,
1998
.
9.
E.
Hildebrandt
,
W.
Bos
, and
R.
Moore
, ASHRAE Technical Data Bulletin Vol.
14
, Issue
2
,
1998
.
10.
S.
Konopacki
and
H.
Akbari
, “
Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin
,”
Lawrence Berkeley National Laboratory
Report LBNL-47149,
2001
.
11.
D.
Parker
,
J.
Sherwin
, and
J.
Sonne
, ASHRAE Technical Data Bulletin Vol.
14
, Issue
2
,
1998
.
12.
A.
Synnefa
,
M.
Santamouris
, and
H.
Akbari
,
Energy Build.
39
,
1167
(
2007
).
13.
N. M.
Nahar
,
P.
Sharma
, and
M. M.
Purohit
,
Build. Environ.
38
,
109
(
2003
).
14.
N. K.
Bansal
and
G.
Minke
,
Climatic Zones and Rural Housing in India
,
Scientific Series of International Bureau
(
Forschungszentrum Jülich GmbH, Zentralbibliothek
,
Jülich, Germany
,
1995
).
15.
Ministry of Power, Government of India
, ECBC, Energy Conservation Building Code,
2007
.
16.
DESIGNBUILDER, web link: http://www.designbuilder.co.uk.
17.
ASHRAE Guideline 14-2002: Measurement of energy and demand savings, American Society of Heating, Refrigerating and Air-Conditioning Engineers.
18.
DOE
, Federal Energy Management Program, M&V Guidelines: Measurement and verification for federal energy projects (FEMP), version 3.0,
2008
.
19.
IPMVP
, Concept and options for determining energy and water savings: Efficiency valuation organization,
2007
.
You do not currently have access to this content.