Power generation from a grid-integrated renewable energy generator embedded with backup sources to form a hybrid energy system possesses convincing features of high efficiency and zero emissions. Control for felicitating apt power sharing and for providing ancillary services such as low voltage ride through (LVRT) is necessary for the compliance of grid codes. However, the simultaneous control coordination for meeting these control objectives is challenging due to the dynamic nature of renewable generators and utility grid. Hence, this paper proposes an integrated power management strategy (PMS) and LVRT control scheme for such systems. A wind energy conversion system backed up by a battery energy storage system, proton exchange fuel cell, and electrolyzer is considered in this work. A reduced rule-based power management control scheme is proposed for the considered system where the request made by the grid operator is kept in priority. Further, a dynamic current feed-forward based LVRT control scheme based on negative sequence current minimization is presented for the grid-interfaced inverter. The inverter control is coupled with an inherent mode selection capability between the grid feeding mode and LVRT mode in order to realize the proposed integrated control objectives. The validation of the proposed PMS and LVRT control is justified by detailing relevant mathematical control models and also by realizing practical case scenarios such as variable wind speed, load demand, grid power request, and occurrences of balanced and unbalanced voltage sag. The obtained simulation results show the cordial response of the system with the proposed control strategies.
Skip Nav Destination
,
,
Article navigation
September 2020
Research Article|
October 19 2020
An integrated rule-based power management and dynamic feed-forward low voltage ride through scheme for a grid-connected hybrid energy system Available to Purchase
Amit Kumar Roy
;
Amit Kumar Roy
1
Electrical and Instrumentation Engineering Department, Thapar Institute of Engineering and Technology
, Patiala 147004, Punjab, India
Search for other works by this author on:
Gyan Ranjan Biswal
;
Gyan Ranjan Biswal
2
Department of Electrical and Electronics Engineering, Veer Surendra Sai University of Technology
, Burla 768018, Odisha, India
Search for other works by this author on:
Prasenjit Basak
Prasenjit Basak
a)
1
Electrical and Instrumentation Engineering Department, Thapar Institute of Engineering and Technology
, Patiala 147004, Punjab, India
a)Author to whom correspondence should be addressed: [email protected]
Search for other works by this author on:
Amit Kumar Roy
1
Gyan Ranjan Biswal
2
Prasenjit Basak
1,a)
1
Electrical and Instrumentation Engineering Department, Thapar Institute of Engineering and Technology
, Patiala 147004, Punjab, India
2
Department of Electrical and Electronics Engineering, Veer Surendra Sai University of Technology
, Burla 768018, Odisha, India
a)Author to whom correspondence should be addressed: [email protected]
J. Renewable Sustainable Energy 12, 056303 (2020)
Article history
Received:
June 23 2020
Accepted:
September 19 2020
Citation
Amit Kumar Roy, Gyan Ranjan Biswal, Prasenjit Basak; An integrated rule-based power management and dynamic feed-forward low voltage ride through scheme for a grid-connected hybrid energy system. J. Renewable Sustainable Energy 1 September 2020; 12 (5): 056303. https://doi.org/10.1063/5.0019254
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Wind and solar energy droughts: Potential impacts on energy system dynamics and research needs
James M. Wilczak, Daniel B. Kirk-Davidoff, et al.
Machine learning for modern power distribution systems: Progress and perspectives
Marija Marković, Matthew Bossart, et al.
Model intercomparison of the ABL, turbines, and wakes within the AWAKEN wind farms under neutral stability conditions
Alan S. Hsieh, Lawrence C. Cheung, et al.
Related Content
Mitigation of harmonics and inter-harmonics with LVRT and HVRT enhancement in grid-connected wind energy systems using genetic algorithm- optimized PWM and fuzzy adaptive PID control
J. Renewable Sustainable Energy (March 2021)
Fault ride-through capability analysis of grid connected wind-DFIG system using SFCL & DVR
AIP Conf. Proc. (May 2024)
Doubly fed induction generator wind turbines: A novel integrated protection circuit for low-voltage ride-through strategy
J. Renewable Sustainable Energy (October 2014)
A reduced-order model for representing the reactive power response of a doubly fed wind turbine during ZVRT
J. Renewable Sustainable Energy (October 2021)
Low voltage ride-through capability improvement of photovoltaic systems using a novel hybrid control
J. Renewable Sustainable Energy (October 2017)