Non-invasive assessment of the plasma parameters is a useful tool for a reliable characterization of many electric thrusters for space applications. Due to high costs, limited availability, and growing use of electric propulsion in spaceflight, alternatives to Xe as a propellant are becoming increasingly important. One option is to use the lighter noble gas krypton or xenon/krypton gas mixtures as a propellant. We propose a versatile analytical approach for establishing empirical correlations between plasma parameters and optical emission (OE) spectroscopy utilizing principal component analysis (PCA). Our approach allows us to establish a surjective mapping of individual OE spectra via their PCA scores onto the corresponding plasma parameters. We prove the feasibility of this approach for Xe, Kr, and Xe/Kr mixed plasmas demonstrating that it is applicable for a wide range of propellant candidates. A major advantage is that the approach does not rely on any microscopic modeling of the OE spectra of the plasma. After having established corresponding reference mappings, the approach can be explored for determining non-invasively and spatially resolved plasma parameters of the propellant plasma of various kinds of operating ion thrusters, which operate in the same plasma regime as the reference plasma. Thus, this method may contribute to shorter qualification and testing times of ion thrusters.
I. INTRODUCTION
Nowadays, electric propulsion (EP) systems are an established option as spacecraft engines.1,2 While they deliver less thrust compared to their chemical counterpart, EP systems excel due to their high fuel efficiency and the vast number of usable propellants yielding a large variability for implementing them in space mission scenarios. There are many types of EP thrusters that generate a propellant plasma in the process of generating thrust. To optimize a thruster without disturbing the plasma, it is favorable to characterize the plasma non-invasively.3,4 Currently, mainly, xenon is used as a propellant due to its high mass, chemical inertness, and fairly low ionization energy. However, xenon is also a rare resource and correspondingly expensive.5,6 Thus, alternatives are sought, such as diluting or replacing xenon with the lighter and ten times more abundant noble gas krypton.7–12 However, the properties of the plasma operated inside the thruster will change when altering the propellant used. Consequently, the operational points of the thruster need to be adjusted. This re-optimization may even require hardware adaptations.7,11,12
The radio-frequency ion thruster (RIT) is one of these established EP systems and was developed at the Justus Liebig University of Giessen in the 1960s.13,14 The plasma discharge in a RIT is achieved by inductive heating of the electrons. When leaving the thruster, positive ions are accelerated by at least two extraction grids to generate a directed ion beam and, therefore, thrust according to Newton’s third law.1,2,15 The functioning of the ion optics of a RIT is determined by the interplay of plasma parameters of the propellant plasma inside the discharge vessel and the grid system. In other words, the geometry of the grid system alone does not define the ion optics. The shape of the plasma meniscus at the grid apertures of the screen grid depends on the plasma parameters and determines the divergence of the ion beamlet inside the grid system.15 A wrong ion beam focusing leads to grid erosion by direct impingement and may drastically reduce the thruster’s lifetime. Knowledge of the plasma parameters, in particular, electron temperature and density, at the actual operational points of the thruster is essential for a successful optimization of the thruster’s performance.15 During thruster qualification, non-invasive diagnostics, such as beam diagnostics, thrust measurement, performance data, and post- or mid-test erosion analysis, are commonly used to obtain information on the operating thruster.16–18 In principle, invasive electrical probes can be used to determine plasma parameters19,20 but are typically undesirable during qualification, as they may itself alter the plasma and, thus, affect the thruster’s performance.19 The plasma of gridded ion thrusters, in particular, will usually not be accessible with invasive probes, if no dedicated openings are available, since such extra openings are not desirable in a flight model; i.e., the grid system or the discharge vessel should not be altered.
Non-invasive alternatives for plasma characterization inside gridded ion thrusters need to be sought. A possible non-invasive diagnostics option is optical emission spectroscopy (OES), which can be used to assess plasma parameters of both beam and discharge by the application of a theoretical plasma model.4,21–28 We recently introduced a method that utilizes non-invasive OES to assess plasma parameters of a thruster operating with xenon non-invasively by applying an empirical correlation between plasma parameters and OES instead of a theoretical model.29 This method utilizes a principal component analysis (PCA)30 and does not rely on any microscopic input other than the measurement of plasma parameters and OE spectra in a reference setup. Since it only requires optical access to the plasma, an OES-based method may be used during terrestrial testing for thruster development or space qualification in cases where an invasive probe cannot be employed. With the plasma parameters provided by this method, grid erosion can be estimated during testing already in the case of gridded ion thrusters. Depending on the type of thruster, an optical probe can be placed strategically to avoid interaction with the plume, allowing one to monitor the thruster with OES and beam diagnostics simultaneously. The high spatial resolution achievable in optical spectroscopy may allow establishing spatial maps of the plasma parameters of an inhomogeneous plasma. An example, where this may be of interest, is the mapping of the radial distribution of plasma parameters inside the discharge vessel of gridded ion thrusters, such as RITs.
In principle, plasma parameters can be extracted from OES using theoretical modeling of the electronic states of the atoms and ions responsible for the optical emission. Such theoretical plasma models can be found, e.g., for argon31–44 and xenon,4,21,22,24–27,41,45–47 but rarely for gas mixtures where even more microscopic processes need to be accounted for in order to obtain a reliable description. There are some studies in which theoretical models were applied to gas mixtures, but those focus on electron excitation only.41,48–51 One exception is Ref. 52, which also considers several atom and molecule collision mechanisms. Such theoretical models are typically set up with a specific application in mind. The specifics of the application will be reflected by the number of electronic states and the selection of the microscopic processes between the species of the plasma, which are taken into account. Taking xenon as an example, Ref. 53 lists 443 electronic states just for neutral xenon, 161 for Xe, 157 for Xe, and more for even higher ionization levels. The amount of electronic states used for theoretical models varies, e.g., 173 states in Ref. 24 or 38 states in Ref. 47. This means that the models are not easily transferable to other applications where the macroscopic excitation and discharge conditions of the plasma have changed. In particular, this also applies for gas mixtures. Adding another atomic species to a propellant, such as krypton to xenon, requires an accurate description of the electronic states of both species and corresponding ions similar to Refs. 41, 48, and 52. Furthermore, an entirely different set of microscopic processes between the xenon and krypton species comes into play, as for describing xenon–krypton collisions and excitation transfer.54–58 A mixed gas model that includes such transfer mechanisms for argon and nitrogen is shown in Ref. 52. The missing parameters, such as cross sections, etc., are difficult to predict with ab initio theories and hard to determine experimentally.59–64
Here, we demonstrate that our non-invasive approach for determining plasma parameters is easily transferable to more sophisticated plasmas, such as those of gas mixtures of xenon and krypton. In future studies, this method might be applied to iodine plasmas as well, as iodine is another promising alternative to xenon as a propellant.65,66 We demonstrate that the challenges met when attempting a microscopic description of such plasmas can be circumvented by our approach, and the plasma parameters can be reliably extracted.
II. EXPERIMENTAL DETAILS
The experimental setup used is shown in Fig. 1. The plasma is generated in a cylindrical RIT-10 (10 cm diameter) quartz glass discharge vessel. The vessel has no extraction system and is operated without surrounding vacuum. Only the inside of the vessel is evacuated via the opening that holds the extraction system in a thruster arrangement. The magnetic field generated by the rf coil with six windings surrounding the vessel is not affected by the exposure to air as the relative permittivity of air and vacuum is almost identical.67 The gas inlet is mounted on the opposite side of the vessel and also contains the Langmuir double probe to determine the electron temperature and density .19,20,68,69
Experimental setup for simultaneous measurement of the optical emission spectrum and the plasma parameters via a Langmuir double probe at the same position. The connections to the computer are shown as red lines. The setup is a modified version of the setup used in the previous work29 yielding higher accuracy and allowing for the operation with mixed gases.
Experimental setup for simultaneous measurement of the optical emission spectrum and the plasma parameters via a Langmuir double probe at the same position. The connections to the computer are shown as red lines. The setup is a modified version of the setup used in the previous work29 yielding higher accuracy and allowing for the operation with mixed gases.
The probe diagnostics were realized with a Keysight B2901A Precision Source/Measurement Unit as a four-wire measurement. The measurement range was to (potential difference between the two probe wires) with voltage steps of and an integration time of . The uncertainty for voltage and current measurement is given in the data sheet of the instrument with and , respectively. The Langmuir probe was built in-house and consists of two cylindrical wires of length and a radius of . The spacing between the wires was .
The optical access to the discharge vessel is given by a glass window, and the focus of the detection optics is positioned in close vicinity of the Langmuir probe. The omission of the extraction system probably causes differences in the gas density distribution. Therefore, it is important to perform OES and Langmuir diagnostics on the same spot so that the correlation can be transferred to a real thruster with different gas density distributions with minimal error. The used Czerny–Turner spectrometer is connected to an intensified charge-coupled device (ICCD) camera (Princeton Instruments PI-MAX 4 1024f). The ICCD is capable of both continuous-wave (cw) and time-resolved measurements on the nanosecond scale but was only used for cw-measurements here. We chose a spectral window from 808 to 837 nm as it contains some of the fastest decaying spectral transitions for both neutral xenon and krypton.70 Examples for xenon and krypton spectra are shown in Fig. 2. The observed optical transitions and feeding transitions of a potential transition chain are listed in Table I. All of the observed spectral transitions have relaxation times shorter than the period of the rf cycle, most of them by about an order of magnitude. The spectral resolution in the observed wavelength region is approximately 28 pm/pixel. The spectra were measured with integration time and were averaged 10 000 times. The ICCD’s intensifier was set to . We found a standard deviation of 1%–2% relative to the average counts for the background region and up to at the peak positions. The response correction was performed with an AVALIGHT-HAL-CAL-MINI calibration source. The gas flow into the discharge vessel is controlled by a set of gas flow controllers (MFC), one for xenon (Bronkhorst EL-Flow F-200CV-AAA-11-V) and another for krypton (Bronkhorst EL-Flow select F-200CV-002-AAD-00-V). Both MFCs have a maximum flow range of xenon. The MFC calibration with the used gases (Kr 5.0 and Xe 4.0) was performed with a Mettler Toledo ME503T/00 scale with a mounted gas reservoir. In this calibration process, the reservoir is evacuated and then filled by setting a constant mass flow on the MFC under calibration. The measured weight is recorded until a total mass of is accumulated. This measurement was done for four different gas flows for both MFCs. A linear fit of the weight over time measurements yields the actual gas flow. A linear fit of the actual gas flows over the nominal gas flows yields the calibration function. The accuracy of the calibration was about for xenon and about for krypton. The plasma was excited by a half-bridge radio-frequency generator (RFG)71,72 at a resonance frequency around 1.6 MHz corresponding to a period of the rf cycle of . The RFG input power was delivered by an Aim TTi CPX400DP power source, and the frequency was measured with a GW Instek GDS-2204E oscilloscope. The RFG input power was varied while keeping the gas flow constant. The experiments were performed for various combinations of xenon and krypton gas flows. The plasma was operated for 5 min at each operational point before starting the measurement to ensure thermal stability during roughly 2 min of measurement time. After changing the gas flow settings, the plasma was allowed to settle for 12 min before commencing the measurements.
Example spectra for both xenon and krypton as well as mixed gas plasma. Additional information about the individual lines can be found in Table I. The shown spectra are intensity-normalized.
Example spectra for both xenon and krypton as well as mixed gas plasma. Additional information about the individual lines can be found in Table I. The shown spectra are intensity-normalized.
Wavelengths, relaxation times, intensities, and the involved electronic states of the observed transitions shown in Fig. 2 are listed for both xenon53,70 and krypton.70,73 The listed intensities are only the qualitative values from Refs. 53 and 73. Using the index, the transitions can be found in Fig. 2. The observed transitions are also shown in bold.
Index . | Wavelength (nm) . | Relaxation time (ns) . | Intensity . | Lower level . | Upper level . | ||||
---|---|---|---|---|---|---|---|---|---|
. | . | . | . | Configuration . | Term . | J . | Configuration . | Term . | J . |
(X0) | 817.10 | n.a. | 100 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°1/2)5d | 2[3/2]° | 2 |
(X0,1) | 722.26 | n.a. | 20 | 5p5(2P°1/2)5d | 2[3/2]° | 2 | 5p5(2P°1/2)6f | 2[5/2] | 3 |
(X0,2) | 800.96 | n.a. | 30 | 5p5(2P°1/2)5d | 2[3/2]° | 2 | 5p5(2P°1/2)5f | 2[5/2] | 3 |
(X1) | 820.63 | 50 | 700 | 5p5(2P°1/2)6s | 2[1/2]° | 0 | 5p5(2P°1/2)6p | 2[3/2] | 1 |
(X1,1) | 3605.49 | 1700 | 20 | 5p5(2P°1/2)6p | 2[3/2] | 1 | 5p5(2P°1/2)5d | 2[5/2]° | 2 |
(X2) | 823.16 | 35 | 10000 | 5p5(2P°3/2)6s | 2[3/2]° | 2 | 5p5(2P°3/2)6p | 2[3/2] | 2 |
(X2,1) | 3107.77 | 1400 | 6000 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)5d | 2[5/2]° | 3 |
(X2,2) | 1672.82 | 556 | 5000 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)7s | 2[3/2]° | 2 |
(X2,3) | 739.38 | 204 | 150 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)7d | 2[5/2]° | 3 |
(X3) | 826.65 | 61.7 | 500 | 5p5(2P°1/2)6s | 2[1/2]° | 1 | 5p5(2P°1/2)6p | 2[1/2] | 1 |
(X3,1) | 4610.87 | 3700 | 1 | 5p5(2P°1/2)6p | 2[1/2] | 1 | 5p5(2P°1/2)5d | 2[3/2]° | 2 |
(X4) | 828.01 | 27.1 | 7000 | 5p5(2P°3/2)6s | 2[3/2]° | 1 | 5p5(2P°3/2)6p | 2[1/2] | 0 |
(X4,1) | 1878.82 | 1100 | 860 | 5p5(2P°3/2)6p | 2[1/2] | 0 | 5p5(2P°3/2)7s | 2[3/2]° | 1 |
(X4,2) | 2651.77 | 6300 | 30 | 5p5(2P°3/2)6p | 2[1/2] | 0 | 5p5(2P°3/2)5d | 2[3/2]° | 1 |
(X5) | 834.68 | 24 | 2000 | 5p5(2P°1/2)6s | 2[1/2]° | 1 | 5p5(2P°1/2)6p | 2[3/2] | 2 |
(X5,1) | 3869.68 | 1900 | 200 | 5p5(2P°1/2)6p | 2[3/2] | 2 | 5p5(2P°1/2)5d | 2[5/2]° | 3 |
(K0) | 810.40 | 153 | 500 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)5d | 2[7/2]° | 4 |
(K1) | 810.44 | 112 | 4000 | 4s24p5(2P°3/2)5s | 2[3/2]° | 2 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 |
(K1,1) | 1317.74 | 204 | 310 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)6s | 2[3/2]° | 1 |
(K1,2) | 1362.24 | 201 | 130 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)4d | 2[3/2]° | 1 |
(K1,3) | 1689.05 | 130 | 340 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)4d | 2[7/2]° | 3 |
(K2) | 811.29 | 27.70 | 500 | 4s24p5(2P°3/2)5s | 2[3/2]° | 2 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 |
(K2,1) | 645.63 | 150 | 200 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)6d | 2[7/2]° | 4 |
(K2,2) | 810.40 | 153 | 500 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)5d | 2[7/2]° | 4 |
(K2,3) | 1363.42 | 97.1 | 250 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)6s | 2[3/2]° | 2 |
(K3) | 819.01 | 112 | 300 | 4s24p5(2P°3/2)5s | 2[3/2]° | 1 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 |
(K3,1) | 985.62 | 251 | 500 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°1/2)4d | 2[3/2]° | 2 |
(K3,2) | 1537.20 | 680 | 725 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)6s | 2[3/2]° | 2 |
(K3,3) | 1678.51 | 148 | 320 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)4d | 2[5/2]° | 3 |
(K4) | 826.32 | 29.27 | 400 | 4s24p5(2P°1/2)5s | 2[1/2]° | 1 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 |
(K4,1) | 1006.60 | 3770 | 10 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)6d | 2[7/2]° | 3 |
(K4,2) | 1388.29 | 94.3 | 27 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 | 4s24p5(2P°1/2)6s | 2[1/2]° | 1 |
(K5) | 828.11 | 70.52 | 200 | 4s24p5(2P°1/2)5s | 2[1/2]° | 1 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 |
(K5,1) | 1012.10 | 1600 | 30 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°3/2)6d | 2[3/2]° | 2 |
(K5,2) | 1383.29 | 321 | 8 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°1/2)6s | 2[1/2]° | 1 |
(K5,3) | 1393.90 | 90.9 | 10 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°1/2)6s | 2[1/2]° | 0 |
(K6) | 829.81 | 34.12 | 500 | 4s24p5(2P°3/2)5s | 2[3/2]° | 1 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 |
(K6,1) | 1442.68 | 108 | 350 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)6s | 2[3/2]° | 1 |
(K6,2) | 1496.19 | 1110 | 290 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)4d | 2[3/2]° | 1 |
(K6,3) | 1693.58 | 173 | 280 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)4d | 2[5/2]° | 2 |
Index . | Wavelength (nm) . | Relaxation time (ns) . | Intensity . | Lower level . | Upper level . | ||||
---|---|---|---|---|---|---|---|---|---|
. | . | . | . | Configuration . | Term . | J . | Configuration . | Term . | J . |
(X0) | 817.10 | n.a. | 100 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°1/2)5d | 2[3/2]° | 2 |
(X0,1) | 722.26 | n.a. | 20 | 5p5(2P°1/2)5d | 2[3/2]° | 2 | 5p5(2P°1/2)6f | 2[5/2] | 3 |
(X0,2) | 800.96 | n.a. | 30 | 5p5(2P°1/2)5d | 2[3/2]° | 2 | 5p5(2P°1/2)5f | 2[5/2] | 3 |
(X1) | 820.63 | 50 | 700 | 5p5(2P°1/2)6s | 2[1/2]° | 0 | 5p5(2P°1/2)6p | 2[3/2] | 1 |
(X1,1) | 3605.49 | 1700 | 20 | 5p5(2P°1/2)6p | 2[3/2] | 1 | 5p5(2P°1/2)5d | 2[5/2]° | 2 |
(X2) | 823.16 | 35 | 10000 | 5p5(2P°3/2)6s | 2[3/2]° | 2 | 5p5(2P°3/2)6p | 2[3/2] | 2 |
(X2,1) | 3107.77 | 1400 | 6000 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)5d | 2[5/2]° | 3 |
(X2,2) | 1672.82 | 556 | 5000 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)7s | 2[3/2]° | 2 |
(X2,3) | 739.38 | 204 | 150 | 5p5(2P°3/2)6p | 2[3/2] | 2 | 5p5(2P°3/2)7d | 2[5/2]° | 3 |
(X3) | 826.65 | 61.7 | 500 | 5p5(2P°1/2)6s | 2[1/2]° | 1 | 5p5(2P°1/2)6p | 2[1/2] | 1 |
(X3,1) | 4610.87 | 3700 | 1 | 5p5(2P°1/2)6p | 2[1/2] | 1 | 5p5(2P°1/2)5d | 2[3/2]° | 2 |
(X4) | 828.01 | 27.1 | 7000 | 5p5(2P°3/2)6s | 2[3/2]° | 1 | 5p5(2P°3/2)6p | 2[1/2] | 0 |
(X4,1) | 1878.82 | 1100 | 860 | 5p5(2P°3/2)6p | 2[1/2] | 0 | 5p5(2P°3/2)7s | 2[3/2]° | 1 |
(X4,2) | 2651.77 | 6300 | 30 | 5p5(2P°3/2)6p | 2[1/2] | 0 | 5p5(2P°3/2)5d | 2[3/2]° | 1 |
(X5) | 834.68 | 24 | 2000 | 5p5(2P°1/2)6s | 2[1/2]° | 1 | 5p5(2P°1/2)6p | 2[3/2] | 2 |
(X5,1) | 3869.68 | 1900 | 200 | 5p5(2P°1/2)6p | 2[3/2] | 2 | 5p5(2P°1/2)5d | 2[5/2]° | 3 |
(K0) | 810.40 | 153 | 500 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)5d | 2[7/2]° | 4 |
(K1) | 810.44 | 112 | 4000 | 4s24p5(2P°3/2)5s | 2[3/2]° | 2 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 |
(K1,1) | 1317.74 | 204 | 310 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)6s | 2[3/2]° | 1 |
(K1,2) | 1362.24 | 201 | 130 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)4d | 2[3/2]° | 1 |
(K1,3) | 1689.05 | 130 | 340 | 4s24p5(2P°3/2)5p | 2[5/2] | 2 | 4s24p5(2P°3/2)4d | 2[7/2]° | 3 |
(K2) | 811.29 | 27.70 | 500 | 4s24p5(2P°3/2)5s | 2[3/2]° | 2 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 |
(K2,1) | 645.63 | 150 | 200 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)6d | 2[7/2]° | 4 |
(K2,2) | 810.40 | 153 | 500 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)5d | 2[7/2]° | 4 |
(K2,3) | 1363.42 | 97.1 | 250 | 4s24p5(2P°3/2)5p | 2[5/2] | 3 | 4s24p5(2P°3/2)6s | 2[3/2]° | 2 |
(K3) | 819.01 | 112 | 300 | 4s24p5(2P°3/2)5s | 2[3/2]° | 1 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 |
(K3,1) | 985.62 | 251 | 500 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°1/2)4d | 2[3/2]° | 2 |
(K3,2) | 1537.20 | 680 | 725 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)6s | 2[3/2]° | 2 |
(K3,3) | 1678.51 | 148 | 320 | 4s24p5(2P°3/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)4d | 2[5/2]° | 3 |
(K4) | 826.32 | 29.27 | 400 | 4s24p5(2P°1/2)5s | 2[1/2]° | 1 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 |
(K4,1) | 1006.60 | 3770 | 10 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 | 4s24p5(2P°3/2)6d | 2[7/2]° | 3 |
(K4,2) | 1388.29 | 94.3 | 27 | 4s24p5(2P°1/2)5p | 2[3/2] | 2 | 4s24p5(2P°1/2)6s | 2[1/2]° | 1 |
(K5) | 828.11 | 70.52 | 200 | 4s24p5(2P°1/2)5s | 2[1/2]° | 1 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 |
(K5,1) | 1012.10 | 1600 | 30 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°3/2)6d | 2[3/2]° | 2 |
(K5,2) | 1383.29 | 321 | 8 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°1/2)6s | 2[1/2]° | 1 |
(K5,3) | 1393.90 | 90.9 | 10 | 4s24p5(2P°1/2)5p | 2[1/2] | 1 | 4s24p5(2P°1/2)6s | 2[1/2]° | 0 |
(K6) | 829.81 | 34.12 | 500 | 4s24p5(2P°3/2)5s | 2[3/2]° | 1 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 |
(K6,1) | 1442.68 | 108 | 350 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)6s | 2[3/2]° | 1 |
(K6,2) | 1496.19 | 1110 | 290 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)4d | 2[3/2]° | 1 |
(K6,3) | 1693.58 | 173 | 280 | 4s24p5(2P°3/2)5p | 2[3/2] | 1 | 4s24p5(2P°3/2)4d | 2[5/2]° | 2 |
In a previously conducted measurement series, we used the glass vessel with an easy optical access to the plasma from behind.29 The setup was rearranged and improved in order to allow detection of the plasma emission from a spot close to the Langmuir probe. The rearrangement of the setup further increases the reliability of the measurement approach. The previously used spectral window from 820 to 840 nm29 was shifted slightly toward shorter wavelengths (808–837 nm), thus sacrificing one small xenon line in favor of a strong krypton double line (K0+K1 and K2 in Fig. 2).
A. Principal component analysis
To analyze the behavior of the relative line intensities for different operational points of the plasma of a species or gas mixture, we performed a PCA30 of all recorded spectra at up to several hundreds of operational points. The PCA technique reduces the dimensions of a dataset with a large number of measured variables. This simplifies the process of correlating the spectral information and the corresponding plasma parameters significantly. PCA is not the only technique capable of dimension reduction. Other methods include linear discriminant analysis,74 non-negative matrix factorization,75 and factor analysis.76 However, we only focus on the PCA here.
For establishing an empirical correlation between OES and plasma parameters, a reference dataset is measured, consisting of a total of spectra. Each spectrum consists of data points or wavelength positions and their respective spectral intensities. In other words, a spectrum is a point in an -dimensional coordinate space, in which the wavelength positions define the coordinate axes and the respective intensities are the coordinates on these axes. By performing a PCA, the -dimensional coordinate space that contains the spectra is, for example, reduced into a two-dimensional coordinate space, in which the individual data points still are well separated. This two-dimensional coordinate space is spanned by two new axes, which typically contain the highest and second highest variance of the dataset.
The process of determining the PCA axes is described in the following. The covariances of each of the wavelength positions with every other wavelength position (including itself) are calculated using
where and are the intensities of spectrum at the two wavelength positions and . The variables and are the average intensities at the wavelength positions and of the average spectrum of all spectra of the recorded set.
With the covariances calculated, the covariance matrix is set up as
The eigenvalues of correspond to the data variances on the principal component axes , which are the eigenvectors of and are spectrum-like with components.
The coordinates (or scores) of a spectrum in this new coordinate system of are calculated as follows:
where is the average spectrum of the reference dataset. The spectrum can now be written as a series expansion,
The fraction in percent of the total variance on each axis shows how much of the variation in the data is represented by the scores of this principal component. Often, the sum the variances on and is already close to 100% of the total variance so that the data can be sufficiently separated in just two dimensions.
B. Evaluation of the Langmuir probe measurements
The Langmuir probe measurements were evaluated using a modified version of the standard procedure.19,20,68,69 This modified approach is more robust against deviations from the theoretical ideal. It was developed in the course of our previously reported experiments29 on the basis of the standard procedure.19,20,68,69 The process is shown in Fig. 3, where the first step is the determination of the ion saturation current . is the intercept of a linear fit [] in the saturation regions shown as red dashed lines in Fig. 3. To correct for the saturation, the slope is subtracted from the –-characteristics [], and the dashed blue curve in Fig. 3 is obtained. The corrected curve is normalized by dividing by (not shown in Fig. 3 for simplicity). The maximum slope of the normalized, corrected curve is proportional to the inverse electron temperature . is obtained by a polynomial fit of third order [] in the region to ; therefore, . The electron temperature in Kelvin is calculated according to
To calculate the electron density , the previously determined values and , as well as the probe area , and the ion mass are needed,
An additional approximation is necessary when the electron density has to be calculated for mixed gas plasmas using Eq. (6). The ion mass is not easily determined, as the mixture consists of the two main ion species Xe and Kr, which both contribute to the measured Langmuir U–I-characteristics. We, therefore, use an approximated effective ion mass for the calculation of . Since the gas flow in sccm represents the number of particles inserted into the discharge chamber, we can calculate the weighted average atomic mass as
assuming equal residence times of the two atomic species inside the discharge chamber. While the exact gas flow does not matter for the evaluation of Langmuir measurements on a pure gas plasma, mixed gas plasmas require calibrated MFCs to avoid errors when employing Eq. (7). If we further assume the ionization degree for xenon and krypton to be identical, effective atomic mass and effective ion mass will be equal (). However, in reality, krypton will have a shorter residence time due to its smaller mass and, therefore, a higher thermal velocity. Furthermore, the higher ionization energy of krypton will result in a lower ionization degree than for xenon. Both effects will push the real effective ion mass further toward that of xenon. Therefore, the real will be probably somewhat higher than estimated. However, our assumptions should be sufficient to demonstrate the basic principle of our approach without going deeper into ionization processes and particle motion.
Langmuir double probe evaluation process illustrated for measurement data of a pure xenon plasma. The linear parts of the measured curve (black line) are fitted to obtain the ion saturation current (red dashed lines). The probe voltage is the potential difference between the two probe wires. The curve is corrected (dashed blue line), and the maximum slope is determined by fitting a third order polynomial (dotted green line) in the vicinity of . The plasma parameters and are calculated using Eqs. (5) and (6).
Langmuir double probe evaluation process illustrated for measurement data of a pure xenon plasma. The linear parts of the measured curve (black line) are fitted to obtain the ion saturation current (red dashed lines). The probe voltage is the potential difference between the two probe wires. The curve is corrected (dashed blue line), and the maximum slope is determined by fitting a third order polynomial (dotted green line) in the vicinity of . The plasma parameters and are calculated using Eqs. (5) and (6).
The definition of a temperature assumes a Maxwellian electron energy distribution function (EEDF).19,20,68 In an rf plasma, the fast electrons in the Maxwell tail are suppressed; therefore, the EEDF can deviate from the Maxwellian ideal.37,77 This also changes the optical spectrum, as excitation rates change. Our empirical approach builds a correlation on a set of experimental data of a real plasma. Thus, as long as another real plasma analyzed on the basis of our reference data is comparable to the one used for acquiring the reference data (which shall be the case, if the optical emission spectra are comparable), the specific EEDF is not too relevant for the outcome of the analysis. We assume that a spectrum will be comparable to the reference spectra, if the plasma under study is driven under comparable experimental conditions (i.e., rf frequency and power, neutral gas densities of the propellant mixture) and if all relative line intensities are within the range of the mapped line intensities. If the PCA scores then fall inside the reference PCA, the correlation will be applicable. However, it should be noted that the validity of the application to a plasma in a setup other than the reference setup is not investigated here. It is yet unclear whether differences in the setup may affect the applicability.
III. RESULTS AND DISCUSSION
During the acquisition of a series of hundreds of spectra, small vibrations or thermal expansion of the measurement equipment might cause small wavelength shifts of the optical transitions of some tens of picometers. Here, the spectra shifted by approximately 1 pixel or over the full measurement series. While they are not relevant for the evaluation, the PCA may be sensitive to such shifts. To circumvent the issue, the spectral information is simplified by integrating the line intensities of the, e.g., six xenon lines shown in Fig. 2. For example, the line intensity of X2 at is determined by adding up all measured intensities between 821.99 and . The PCA is then performed with these line intensities as input. The obtained principal components ( for xenon) are the new coordinate axes with maximum data spread, where covers the highest variance, followed by , etc.
First, we conducted measurements on a pure xenon plasma at various gas flows and input powers. and cover the majority of the data variance. However, due to a wide range of rf power, the first two principal components are not fully sufficient to separate the spectra in the corresponding 2D representation for all operational points of the plasma, with each spectrum corresponding to another set of plasma parameters. To fully separate the spectra, the third axis also has to be considered. For this purpose, we define a new axis direction in the / plane as a linear combination of and defined by the vector ,
Choosing and in this case yields a satisfactory separation of the data points (each corresponding to a spectrum of a specific operational point of the plasma) when plotting the corresponding scores in a projected 2D representation vs as shown in Fig. 4(a). The scores in Fig. 4(a) reveal a regular pattern with clear trends as functions of the external input parameters, i.e., the rf power coupled into the plasma and the propellant gas flow defining the neutral gas density of the plasma. A variation of the gas density for a given power yields almost straight lines in the 2D plane, whereas the variation of the rf power at a fixed density leads to curves as indicated in the figure.
PCA scores of a series of xenon spectra taken at various gas flows (a). The three-dimensional scores are displayed in two dimensions with the x axis being a vector on the – plane to better visualize the spread in the OES data. The corresponding plasma parameters measured with the Langmuir double probe of the same series are shown in (b). The fits of the electron density (c) and the temperature (d) over the modified PCA scores are the correlation between OES and plasma parameters for pure xenon.
PCA scores of a series of xenon spectra taken at various gas flows (a). The three-dimensional scores are displayed in two dimensions with the x axis being a vector on the – plane to better visualize the spread in the OES data. The corresponding plasma parameters measured with the Langmuir double probe of the same series are shown in (b). The fits of the electron density (c) and the temperature (d) over the modified PCA scores are the correlation between OES and plasma parameters for pure xenon.
The corresponding plasma parameters shown in Fig. 4(b) measured simultaneously with the spectra exhibit the anticipated trends.15,78,79 Lowering the xenon gas flow increases the electron temperature. The electron density increases with higher input power. The maximum electron density reached for lower gas flow decreases, as the input power limitation is reached earlier. An interesting pattern occurs at low input powers, where the mapping was done in small power steps. Here, the electron temperature rises with increasing electron density and falls off again exhibiting a sharp maximum at around . Currently, we seek a satisfactory explanation for this behavior.
Having established a 2D representation in a 2D plane of the coordinate space in Fig. 4(a), which virtually separates the data points representing all spectra taken at different operational conditions and having shown in Fig. 4(b) that the plasma parameters and show the anticipated trends, we can now parameterize the dependence of and on the coordinates given by the chosen new axes. To describe the plasma parameters in Fig. 4(b) as a function of the scores shown in Fig. 4(a), we introduce the fitting function,
Here, is the modified score value according to Eq. (8) and is the polynomial order of the fit. Using the fitting function in Eq. (9) with a polynomial order of , the -values for the and fits are 0.954 and 0.990, respectively. Since the function in Eq. (9) is three-dimensional, the fits can be displayed and are shown in Figs. 4(c) and 4(d). The two 3D plots clearly demonstrate that the PCA can indeed establish correlations between plasma parameters and the optical emission spectra. Of course, such a parameterization is best in the center of the set of data points and deviates toward the edges of the fitted 2D surface. In this measured dataset, we find the deviation between measured and calculated plasma parameters to be about for and for when the edges of the contour fitting are avoided. For the anticipated application, i.e., the non-invasive determination of the plasma parameters inside an ion thruster, it will be of major importance that the operational points of its plasma lie well inside the parameter space of operational points of the reference plasma. However, if this is given, the plasma parameters can be determined non-invasively with a high degree of accuracy.
Using the same approach, we can also analyze the OES data for krypton plasmas. The data points corresponding to the optical emission spectra recorded at different operational points of the plasma can be separated quite well when plotting their PC scores in the plane spanned by and as shown in Fig. 5(a). However, there is no angle at which the first three principal component scores can be projected to a 2D representation without major overlapping of data points.
PCA scores for a series of krypton spectra taken at various gas flows (a). The data spread can be seen best when observing the three-dimensional scores in the – plane. The corresponding plasma parameters measured with the Langmuir double probe for this series are shown in (b). A fit for each principal component as a function of new coordinates and is shown in (c). The data points of and in (c) are shifted upward for a better visual representation. The values for the new variables and are assigned to the data points in the PCA coordinate space according to their position on the mesh shown in (a). The plasma parameters can also be fitted as functions of the – coordinates, as shown for electron density (d) and temperature (e). This yields a correlation between optical emission spectra and plasma parameters with one additional step to perform compared to the projection method used for xenon in Fig. 4.
PCA scores for a series of krypton spectra taken at various gas flows (a). The data spread can be seen best when observing the three-dimensional scores in the – plane. The corresponding plasma parameters measured with the Langmuir double probe for this series are shown in (b). A fit for each principal component as a function of new coordinates and is shown in (c). The data points of and in (c) are shifted upward for a better visual representation. The values for the new variables and are assigned to the data points in the PCA coordinate space according to their position on the mesh shown in (a). The plasma parameters can also be fitted as functions of the – coordinates, as shown for electron density (d) and temperature (e). This yields a correlation between optical emission spectra and plasma parameters with one additional step to perform compared to the projection method used for xenon in Fig. 4.
Nevertheless, the plot of the electron density vs electron temperature in Fig. 5(b) shows again clear trends as a function of rf power and gas flow. The electron temperatures reach higher levels than for xenon, while the electron densities are somewhat smaller. Due to the higher ionization energy of krypton, more energy is needed for heating of the electrons before ionization is possible. Therefore, a hotter, less dense plasma is expected.
Contrary to the xenon case, the two plasma parameters cannot be fitted to a fitting curve according to Eq. (9), as the overlapping shown in Fig. 5(a) prevents a direct surjective correspondence. One possibility to set up a parametric correlation is employing a higher dimensional fit, thus yielding and . However, such a fit cannot be presented in a 3D plot. Therefore, we use an alternative approach. As the data cloud forms a 3D surface, another option is to find a parametric description of that surface with two variables and and to establish correlations and . For this purpose, we created a mesh from the PCA results as shown in Fig. 5(a). We then assigned and values to the individual measurements according to their position on that mesh so that increases with decreasing input power, while increases with decreasing mass flow. The PCA scores can then be fitted as a function of the – coordinates as shown in Fig. 5(c). The corresponding plasma parameters shown in Fig. 5(b) can also be fitted as functions of the – coordinates as shown in Figs. 5(d) and 5(e). All fits were performed using fitting functions of the type,
with . The values were 0.978 for , 0.986 for , 0.991 for , 0.918 for , and 0.997 for .
A new spectrum measured at an operational point where the plasma parameters shall be determined can now be transferred in the PCA coordinate space using Eq. (3). To obtain the plasma parameters for this operational point, the – coordinates have to be determined. By looking at the position of the corresponding PCA-point on the mesh shown in Fig. 5(a), – coordinates can be estimated. The – values can now be refined using the previously found functions and minimizing the sum of the relative quadratic deviations of the measured scores of the spectrum and the calculated scores using
The refined – values can then be used to obtain and using the previously found functions and . This method is, however, somewhat reliant on the quality of the parameterization and a good first estimation of and . Especially toward the edges of the fitting regions, this method becomes less reliable. In our measured dataset, if good first estimations are used and the edges are avoided, we find the deviation between measured and calculated plasma parameters to be about for and for .
After having demonstrated that our approach is suitable for plasmas of pure xenon and krypton propellants, we will now turn to its use for analyzing plasmas of gas mixtures of xenon and krypton. The spectra of the xenon/krypton plasma shown in Fig. 2 indicate one of the challenges typical in analyzing OES data of mixed plasma. In the spectral window selected by us, the spectral lines of xenon and krypton, X3 and K4, and X4 and K5 overlap. We have handled this situation by considering these lines as one line in the simplification procedure prior to the PCA. Furthermore, we have performed multiple series of combined OES and Langmuir measurements where we have kept the krypton gas flow constant and varied the xenon gas flow. In other words, the mixing ratio is not constant throughout a series. We have acquired datasets for the four constant krypton gas flows 0.354, 0.218, 0.147, and 0.108 sccm. In what follows, we will exemplarily discuss the data set where the krypton gas flow was set to 0.218 sccm and the xenon gas flow was varied between about 0.1 and 0.4 sccm.
As for the pure propellants, the PCA results of the mixture allow one to separate all the data points corresponding to optical emission spectra taken at different operational conditions as shown in Fig. 6(a). Thus, the projection method could be employed similar to the pure xenon case. The projection plane was spanned by and the linear combination of . Again, clear trends in the 2D plot can be observed as a function of increasing xenon flow as well as in dependence on rf power as indicated in Fig. 6(a).
PCA scores of the xenon/krypton mixed gas OES measurements for a constant krypton gas flow of 0.218 sccm and variable xenon gas flow (a). Like in Fig. 4(a), the three-dimensional scores are displayed in two dimensions with the x axis being a vector on the – plane to better visualize the spread in the OES data. The corresponding plasma parameters from the Langmuir double probe measurements are shown in (b). The fits of the electron density (c) and temperature (d) over the modified PCA scores are the correlation between OES and plasma parameters for the mixed gas plasma with a constant krypton gas flow of 0.218 sccm.
PCA scores of the xenon/krypton mixed gas OES measurements for a constant krypton gas flow of 0.218 sccm and variable xenon gas flow (a). Like in Fig. 4(a), the three-dimensional scores are displayed in two dimensions with the x axis being a vector on the – plane to better visualize the spread in the OES data. The corresponding plasma parameters from the Langmuir double probe measurements are shown in (b). The fits of the electron density (c) and temperature (d) over the modified PCA scores are the correlation between OES and plasma parameters for the mixed gas plasma with a constant krypton gas flow of 0.218 sccm.
The same holds for the plot of electron temperature vs electron density in Fig. 6(b). Characteristic curves are obtained as a function of added xenon gas flow and as a function of rf power. These resemble those obtained for the pure propellants.
As expected, the electron temperature rises with decreasing gas flow. However, the differences in the electron temperature for different xenon gas flows shown in Fig. 6(b) become smaller with decreasing xenon gas flows. The rise in the electron temperature is a result of lower neutral gas density, where the electrons acquire more energy per rf half cycle, as they have a lower probability to collide with atoms and ions. In this case, only the xenon gas flow of the gas mixture is lowered; therefore, only the neutral xenon density is reduced. Since the krypton gas flow remains constant, the overall neutral gas density approaches a constant value greater than zero. Decreasing the xenon gas flow from, e.g., 0.120 to 0.111 sccm, has less effect on the plasma parameters than in pure xenon as the krypton atoms present as a background serve as collision partners for the electrons. Vice versa, a small portion of xenon in the plasma still provides enough easily ionizable atoms to keep the electron temperature below the ones shown in Fig. 5(b) for pure krypton.
These findings allow us to plot surfaces of the plasma parameters in dependence of the PCA based coordinates selected for achieving the separation into two dimensions in Fig. 6(a). The two surface fits of electron density and electron temperature are shown in Figs. 6(c) and 6(d), respectively. Here, Eq. (9) was applied with a polynomial order of , yielding an of 0.980 for and 0.978 for . In this mixed gas dataset, we find the deviation between measured and calculated plasma parameters to be about for and for when the edges of the contour fitting are avoided. Similar results have been obtained for the other xenon/krypton gas mixture series based on constant krypton gas flows of 0.354, 0.147, and 0.108 sccm, which are provided in the data availability statement. The results strongly suggest that a similar analysis and the establishment of a surjective mapping of the PC scores of spectra onto the corresponding plasma parameters are also possible for datasets taken of xenon/krypton gas mixtures with constant fractions of xenon and krypton.
The situation is different when simultaneously performing a PCA of the full dataset, i.e., of all spectra taken at different xenon and krypton gas flows and rf powers. In this case, we cannot find a 2D plane in the coordinate space of the spectra where the data points representing the spectra are clearly separated. This means that at least a third principal component based coordinate axis is required to achieve a full separation of the data points representing the spectra. However, this is somewhat anticipated as three external control parameters, xenon gas flow, krypton gas flows, and rf power, are variable in this situation. However, it should still be possible to establish a corresponding surjective mapping between PC scores and plasma parameters, but it will be of higher dimensionality than two-dimensional.
IV. CONCLUSION
We have developed an empirical approach for correlating optical emission spectra of gas plasmas obtained at different operational points with the corresponding plasma parameters. For this purpose, we measured the optical emission spectra of xenon, krypton, and xenon/krypton mixed plasmas at different operational points and simultaneously performed Langmuir probe measurements. The different operational points were defined by tuning two external parameters, the propellant gas flow (in the case of the gas mixtures, the gas flow of one constituent, while keeping that of the other constant), as well as the power coupled into the plasma for each set of combined optical emission and Langmuir measurements. The Langmuir measurements at each operation point were analyzed to extract electron temperature and electron density. For each set of optical emission spectra, a principal component analysis was conducted in order to present the differences in the set of spectra by a reduced number of characteristic coordinates based on the principal components. For all sets of spectra, it was possible to unambiguously characterize each spectrum of the set by two such characteristic coordinates only. This was demonstrated for xenon by using a projection method and for krypton by using a – mapping method. In a corresponding, two-dimensional plot in the plane spanned by these two coordinates, the data points representing the spectra can be well separated. This separation allows us to parameterize the plasma parameters as a function of the two coordinates, i.e., to establish a surjective mapping of the optical spectra onto the plasma parameters. In particular, the finding that this approach is successful for rather complex plasmas, such as those of gas mixtures, fortifies our view that the approach will also be applicable to various types of alternative propellants in future studies, for example, iodine, whose plasma is difficult to describe by microscopic theories. Having established such a reference set by simultaneously performing optical emission spectroscopy and Langmuir measurements, the next step is to employ the surjective mappings for a non-invasive determination of the plasma properties of unknown plasmas provided the same gas is used and the operational parameters lie within those of the reference set. Such plasmas may be those inside an ion source or ion thruster where an invasive probe, such as a Langmuir probe, may not be used as it may affect the plasma properties (e.g., in the case of very small discharge vessels) or where no suitable access for the probe is available (e.g., in electric thrusters that shall be qualified for space). Future studies may also examine the spatial distributions of the plasma parameters inside a RIT using this approach. The presented method of non-invasively determining the plasma parameters by optical spectroscopy will considerably contribute to a better understanding of ion thrusters and to speeding up their development and qualification for space.
ACKNOWLEDGMENTS
Benny Nauschütt is grateful for receiving a Ph.D. studentship in the framework of the JLU-Ariane Group Graduate School “Radio frequency ion thrusters.” This work was supported by ERDF within the Horizon 2020 program (Innovation Lab “Rough ambient physics”).
AUTHOR DECLARATIONS
Conflict of Interest
The authors have no conflicts to disclose.
DATA AVAILABILITY
The datasets used and/or analyzed during the current study are available from JLUdata under the link “http://dx.doi.org/10.22029/jlupub-234” for the xenon and mixed gas measurements and “http://dx.doi.org/10.22029/jlupub-300” for the krypton measurements.