In this work, it is shown that image reconstruction methods from ultrasonic imaging can be employed for thermographic signals. Before using these imaging methods, a virtual signal is calculated by applying a local transformation to the temperature evolution measured on a sample surface. The introduced transformation describes all the irreversibility of the heat diffusion process and can be used for every sample shape. To date, one-dimensional methods have been primarily used in thermographic imaging. The proposed two-stage algorithm enables reconstruction in two and three dimensions. The feasibility of this approach is demonstrated through simulations and experiments. For the latter, small steel beads embedded in an epoxy resin are imaged. The resolution limit is found to be proportional to the depth of the structures and to be inversely proportional to the logarithm of the signal-to-noise ratio. Limited-view artefacts can arise if the measurement is performed on a single planar detection surface. These artifacts can be reduced by measuring the thermographic signals from multiple planes, which is demonstrated by numerical simulations and by experiments performed on an epoxy cube.

Active thermography is used for detection, imaging, and sizing of structural imperfections in a non-destructive way.1 Applications range from diagnosis of sub-surface defects and material characterization up to online and inline inspection.2 Active thermography involves heating or cooling of a sample to create a temperature gradient and observation of the heat diffusion process by measuring the infrared thermal signature of the sample using an infrared camera. To heat up the sample, various methods are used including a flash-lamp or laser-heating,3–6 ultrasonic waves,7 or inductive heating.8 Various temporal excitation methods, such as pulses in pulsed thermography,9 or frequency-domain signals with a single-frequency lock-in technique,10 are applied to heat the sample. Pulsed phased infrared thermography (PPT) combines simultaneously advantages of pulsed and lock-in thermography.11 Besides a larger depth range,12 another advantage of phase angle images is that they ignore the surface structures related to optical and infrared properties10 and therefore the unwanted effects from environmental reflections, emissivity variations, or non-uniform heating are suppressed. An alternative excitation method called truncated-correlation photothermal coherence tomography (TC-PCT), which also combines the advantages of time- and frequency domain methods, was inspired by the radar technology and uses a chirped pulse approach in which a broadband thermal relaxation chirp is cross-correlated with a sequence of delay-swept and pulse-width-truncated references.13 

Heat diffusion and the propagation of an undamped acoustic wave are mathematically modeled by the diffusion equation and the wave equation, respectively. Both equations are second order linear partial differential equations in space and time but describe a quite different physical phenomena. While undamped acoustic waves are invariant to time reversal and therefore can be used for ultrasound image reconstruction,14 the diffusion of heat is an irreversible process, which cannot be time-reversed. As described by Salazar,15 in contrast to an acoustic wave, “thermal waves” do not have a mean energy propagation.

Damped acoustic waves can be modeled in the temporal Fourier space (ω – space) by the Helmholtz equation16 with a complex wave number K(ω), where the imaginary part is equal to the attenuation coefficient in space.17 La Riviere et al.18 introduced a local transformation of the acoustic wave without damping to the actual measured signal including damping. The inverse transformation of the measured damped acoustic wave to the virtual wave without damping is ill-posed and has to be regularized in order to reconstruct acoustic images from the signals. The evolution in space and time of this virtual wave signal is described by the wave equation and, therefore, all well-known reconstruction algorithms from ultrasound imaging or from photoacoustic tomography14,19,20 can be used to reconstruct the acoustic pressure distribution in space for earlier times. In particular, the initial pressure distribution can be reconstructed for a time just after the excitation pulse. One reconstruction method which directly uses the time invariance of the virtual wave signal is time-reversal reconstruction,14,21,22 and another one which works well for planar sample surfaces is the frequency domain synthetic aperture focusing technique (F-SAFT).23–25 

In this work, we introduce the concept of virtual waves for thermographic image reconstruction for the case of short excitation pulses. However, the introduced concept can be easily transferred to other temporal excitation schemes. In Sec. II, a local transformation similar to that of damped acoustic waves is used to calculate a virtual wave from the measured temperature signal. From this virtual wave signal, the original temperature distribution directly after the excitation pulse can be reconstructed by using any ultrasound reconstruction method. As the sample surfaces are planes, F-SAFT was used. The reconstruction capability of this method was demonstrated in one, two, and three dimensions using the data obtained by simulations and experiments. The reconstruction process is a two-stage process. In the first step, a virtual wave is calculated for every location of the temperature evolution on the surface. As the virtual wave is mathematically described by the wave equation, it can be reversed in time. This feature is used in a second step in order to reconstruct the temperature distribution in space inside samples just after the excitation pulse. The first step, calculating the virtual wave, allows for all of the algorithms developed for ultrasound reconstruction to be used for thermographic reconstruction. This local transformation is presented in Section II A. Its inverse is ill-posed and requires regularization. The influence of the regularization on the spatial resolution is given in Section II B. Its thermodynamic background is discussed in the  Appendix, where relevant prior results are also reviewed. Section III shows the simulation results in two and three dimensions, which verify these resolution limits. In Section IV A, the resolution limits are verified experimentally using two small spherical steel beads embedded in epoxy, heated by a short electromagnetic pulse. In Section IV B, a second experimental set-up is presented where four steel beads are embedded at various depths in an epoxy cube. The infrared camera measures the temperature evolution of three orthogonal surface planes of the cube after heating by a short electromagnetic pulse. Joint reconstruction is then used to calculate a three-dimensional representation of the original heat distribution within the sample. We coin the term “thermo-tomography” for this method, where thermo-tomography refers to the measurement of the temperature evolution on different surfaces and joint reconstruction to generate a three-dimensional representation of the initial heat distribution.

Temperature signals are mathematically modeled by the heat diffusion equation, whereas undamped acoustic waves are modeled by the wave equation. Linearity assures that all solutions of both equations can be represented in the temporal Fourier space (ω – space) as a superposition of “wave trains” having a certain frequency ω. The “thermal wave” is a solution of the heat diffusion equation in ω – space for a certain frequency ω, which is Fourier-transformed back to real space. From the linearity of the diffusion equation, it is evident that such “heat wave trains” show an interference behavior,26 as every superposition of them is again a solution of the diffusion equation. For acoustic waves, this interference behavior is widely accepted.

To calculate the virtual wave signals from local temperature signals, we introduce a similar local transformation as used by La Riviere et al.18 for damped acoustic waves (see Section I). In this work, the Helmholtz equation was not solved directly, but a relation between the signal in the presence of attenuation to an ideal signal, as would have been obtained in the absence of attenuation, was derived. This ideal pressure signal is not a real pressure wave, but only a mathematical construct, which is used for the reconstruction of the initial pressure distribution. The real measured pressure wave is the attenuated signal and in an experimental set-up, one cannot only measure the ideal signal without the attenuation.

Here, such a relation between the temperature signal described by the heat diffusion equation and a virtual temperature signal is derived. The evolution in space and time of this virtual temperature wave signal is described by the wave equation and, therefore, all the reconstruction methods known from ultrasound imaging can be applied to reconstruct the temperature distribution for a time just after the excitation pulse. Like the ideal wave in an acoustic lossy medium, this temperature wave signal has no real physical realization. It is only used for mathematical reconstruction and is therefore ‘virtual’.

Ammari27 derived the same relation as La Riviere et al.18 directly from the equations in the ω – space. In this section, this compact derivation is presented for the heat diffusion equation.

Thermal diffusion can be described by the diffusion equation28 

(1)

where T(r,t) is the temperature as a function of space and time, 2 is the Laplacian (second derivative in space), and α is the thermal diffusivity which is assumed to be homogeneous in the sample. The source term on the right side of Eq. (1) ensures that the temperature just after the short excitation pulse, which is modeled by the temporal Dirac delta function δ(t), is T0(r). This description of the thermal diffusion is based on the Fourier's law, which is valid for macroscopic samples, where the propagation distance is much larger than the phonon mean free path.29 

The wave equation describes the acoustic pressure p(r,t) as a function of space r and time t and can be written as30,31

(2)

where c is the speed of sound, and p0(r) is the initial pressure distribution just after the short excitation pulse. Now a virtual wave Tvirt(r,t) is defined in a way that the same wave equation is valid with the initial temperature distribution T0(r) and an arbitrarily chosen c, usually set equal to one

(3)

θ is the temperature signal in ω – space, calculated by the temporal Fourier transform

(4)

and similar θvirt(r,ω) is the Fourier transform of the virtual wave Tvirt(r,t). Taking the Fourier transform according Eq. (4) of Eq. (1) results in

(5)

and of Eq. (3) gives

(6)

which are two Helmholtz equations: Eq. (6) with a real wavenumber k(ω) and Eq. (5) with a complex wavenumber σ(ω). Replacing ω by icσ(ω) in Eq. (6) gives Eq. (5) by identifying

(7)

Eq. (7) is the sought relation between the measured temperature signal and the virtual wave signal in ω – space. It is a local transformation, as the location r is the same for θvirt and θ, and it is valid in all dimensions. Transformation back from ω – space to the time domain (inverse Fourier transform) by using Eq. (4) results in

(8)

which can be integrated analytically in ω and can be written as

(9)

Eq. (9), like Eq. (7) connects the temperature signal to the virtual wave signal at the same location r, but in time domain instead of the temporal frequency domain. It can be discretized to produce a matrix equation

(10)

where T and Tvirt are the vectors of the measured temperature signal and of the virtual wave signal at discrete time steps, respectively. K is the matrix at these time steps calculated from Eq. (9). Eq. (10) can be inverted only with appropriate regularization, as the matrix K shows a deficient in rank. The truncated singular value decomposition (SVD) method is used to get the reconstructed signal Trec as an estimate for Tvirt from the thermographic signal T.32 The truncation value for the smallest singular values is 1/SNR, with SNR being the signal-to-noise ratio.

The inversion of matrix Eq. (10) is ill-conditioned, meaning that small fluctuations in T are highly amplified when calculating Trec as an estimate for Tvirt. It needs to be re-formulated for a numerical treatment by including additional assumptions, such as limiting the variation of the solution.33 This mathematical reformulation is known as regularization, including truncated SVD or Tikhonov regularization.34 The choice of a proper regularization parameter is critical, e.g., for the truncated SVD method, this is the smallest singular value taken into account.

As reviewed in  Appendix, the best reconstruction possible in the temporal frequency domain (ω-space) is obtained by using frequencies up to a truncation frequency, ωtrunc. A sharp pulse in Tvirt, ideally a Dirac delta pulse, will keep its shape, as the wave equation Eq. (3) has only solutions without dispersion. In ω-space, θvirt will also keep high frequencies after the pulse travels some distance rct. From the delta pulse in Tvirt, the corresponding temperature signal T will get broadened with increasing r according to Eq. (9). In the frequency domain, this corresponds to θ(r,ω)=12ασ(ω)exp(σ(ω)r)=12iωαexp(iω/αr), as can be seen by applying the Fourier transform (4).35 The temperature signal in ω-space is a superposition of the spectral components of “thermal waves” with an angular frequency ω and wavenumber k(ω):=ω/2α. At a distance r for a certain frequency ω the amplitude is damped by exp(rω/2α). A “thermal wave” with frequency ωtrunc is damped at a distance r by the factor exp(rωtrunc/2α) just to the noise level, which gives

(11)

with the signal-to-noise ratio SNR and ln is the natural logarithm. By applying the inverse Fourier transform, Eq. (4) up to the frequency ωtrunc it follows that the reconstructed temperature signal Trec for the initial time t=0 is proportional to36 

(12)

In Fig. 1, this reconstructed signal Trec is shown for several delta peaks of the virtual signal Tvirt and compared to the reconstructed signal calculated by the truncated SVD method described in Section A for two different SNR values. As the resolution limit is the size of a small (ideally point-like) reconstructed structure at a certain depth, the resolution μ after some time t, or some travelling distance r=ct, is the width of the reconstructed signal calculated by the truncated SVD method (dashed line in Fig. 1). This is in good agreement with the distance of the zero points of the reconstructed signal in Eq. (12)

(13)
FIG. 1.

Reconstructed temperature signal from a virtual signal Tvirt (dotted red line) with peaks at a depth of 20, 40, 80, and 160. The reconstructed signal Trec is calculated by the truncated SVD method, described in Section A (dashed blue line), and by using the truncation frequency ωtrunc and Eq. (12) (bold black line). The resolution μ after some time t (or some travelling distance r=ct) is the width of Trec using ωtrunc and agrees with the “wavelength” at ωtrunc (zero points of the reconstructed signal in Eq. (12)). The signal-to-noise ratio SNR was chosen 2000 in (a) or 20002 in (b).

FIG. 1.

Reconstructed temperature signal from a virtual signal Tvirt (dotted red line) with peaks at a depth of 20, 40, 80, and 160. The reconstructed signal Trec is calculated by the truncated SVD method, described in Section A (dashed blue line), and by using the truncation frequency ωtrunc and Eq. (12) (bold black line). The resolution μ after some time t (or some travelling distance r=ct) is the width of Trec using ωtrunc and agrees with the “wavelength” at ωtrunc (zero points of the reconstructed signal in Eq. (12)). The signal-to-noise ratio SNR was chosen 2000 in (a) or 20002 in (b).

Close modal

The resolution limit is proportional to the travel distance r of the signal between excitation location and detection point and inversely proportional to the natural logarithm of the signal-to-noise ratio. The resolution does not depend on the thermal diffusivity α. For a SNR value of 2000 (Fig. 1(a)), the resolution is approximately 17, 33, 66, and 132 for a travel time or distance r of 20, 40, 80, and 120, respectively. For the squared SNR value of 20002 the resolution μ is found to be 8.5, 16.5, 33, and 66, according to Eq. (13) (Fig. 1(b)).

The one-dimensional solution of the wave equation is a wave package of constant shape travelling with sound velocity c (already published in 1747 by d'Alembert). Therefore, in one dimension (1D), the virtual wave immediately gives the reconstructed image at time t=0 by projecting it back a distance ct. For higher dimensions, at a certain time t the signals from all locations at the distance ct, which is a circle or sphere, interfere and summate. Reconstruction methods known from ultrasound imaging like spherical backprojection19 (or other methods as mentioned in Section I) are used as a second step for image reconstruction from the calculated virtual wave signals. In this section, the sample is assumed to be thermally isolated, which results in adiabatic boundary conditions where the heat flux and, therefore, the normal derivative of the temperature T(r,t) at the sample boundary vanishes at all times t. As no heat can flow in or out of the sample, after a long time, a thermal equilibrium will be established at an equilibrium temperature, which is above the ambient temperature by an amount equal to the energy of the heating pulse divided by the heat capacity and the mass of the sample.

For the numerical examples shown in this section, the Fourier transform in space was used to determine T(r,t) from the initial temperature distribution T0(r).35,36 In this Fourier space, called “k-space” corresponding to ω-space for the temporal frequency domain, the temperature evolution in time is a simple multiplication by exp(k2αt), with a wave vector k37 and thermal diffusivity α, which was assumed to be homogeneous in the sample (see Eq. (1)). For adiabatic boundary conditions, the eigenfunctions are cosine functions38 with a zero gradient at the sample boundaries. Therefore, first, the discrete cosine-transform T0̂(k) from T0(r) is calculated. Then for a later time t

(14)

The inverse cosine transform gives T(r,t), which is evaluated at the sample surface points rS to simulate the measured surface temperature T(rS,t). Added Gaussian noise provides the desired signal-to-noise ratio. As a numerical example for an initial temperature distribution T0 three small Gaussian peaks were chosen on a two-dimensional (2D) 200 × 100 grid (Fig. 2(a)). To calculate the discrete cosine transform T0̂, the time evolution T̂ according to Eq. (14), and the inverse discrete cosine transform to determine the surface temperature T(rS,t) (Fig. 2(b)), a short MATLAB routine was written. More details are given in Sec. III A.

FIG. 2.

2D reconstruction example: (a) cross section perpendicular to the surface (z=0) of the initial temperature distribution T0(y,z), consisting of three small Gaussian peaks, centered at (150,20), (100,40), and at (50,80). (b) “Measured” surface temperature T(y,t) at depth z=0, calculated in k – space using Eq. (14) from the initial temperature distribution in (a). (c) Virtual wave signal Trec(y,t) calculated by the truncated SVD method (Section II A). (d) Reconstruction of the initial temperature distribution T0,rec(y,z) using F-SAFT.

FIG. 2.

2D reconstruction example: (a) cross section perpendicular to the surface (z=0) of the initial temperature distribution T0(y,z), consisting of three small Gaussian peaks, centered at (150,20), (100,40), and at (50,80). (b) “Measured” surface temperature T(y,t) at depth z=0, calculated in k – space using Eq. (14) from the initial temperature distribution in (a). (c) Virtual wave signal Trec(y,t) calculated by the truncated SVD method (Section II A). (d) Reconstruction of the initial temperature distribution T0,rec(y,z) using F-SAFT.

Close modal

For every detection point rS the truncated SVD method (Section II A) was used to calculate the reconstructed virtual wave signal Trec(rS,t). Trec is the estimated virtual wave which is used in 2D and 3D to reconstruct the initial temperature distribution T0,rec(r). As detection surfaces for the simulations and experiments are planes F-SAFT,23–25 a well-known ultrasound image reconstruction method was used, but the other methods such as time-reversal reconstruction also show similar results.14 

Fig. 2 gives a 2D example for a reconstruction from simulated data, with a lateral dimension y (length 200) and the depth z (maximum depth 100). The initial temperature distribution T0(y,z) and its temporal evolution according to the heat diffusion equation were calculated on this 200 × 100 grid, using adiabatic boundary conditions. As described in the beginning of Section III, the adiabatic boundary conditions were implemented by calculating the 2D discrete cosine transform T0̂(ky,kz) from T0(y,z). For a later time t=1,2,100T̂(ky,kz,t) is calculated in k – space by multiplication with exp(k2αt) according to Eq. (14). The thermal diffusivity α was chosen equal to 10. The inverse 2D discrete cosine transform gives the temperature distribution T(y,z,t) on the 200 × 100 numerical grid. For reconstruction, only the surface temperature at z=0 is taken: T(y,t)=T(y,z=0,t). Experimentally, such a 2D heat diffusion could be realized, e.g., by embedding the thin parallel wires in a sample, which are heated by a short electrical pulse. Fig. 2(a) shows the cross-section into the depth of the sample of the initial temperature distribution T0(y,z) with three small Gaussian peaks with a full width at half maximum of 5 at depths z of 20, 40, and 80, equal to the positions of the peaks for the 1D example in Fig. 1. The SNR was chosen 20002 divided by the square root of the number of measured data points (pixel number of the camera) to get a comparable result to Fig. 1(b). Fig. 2(b) shows the simulated “measured” surface temperature T(y,t) for every lateral distance y as a function of time. The corresponding virtual wave signal Trec(y,t) calculated by the truncated SVD method (Section II A) is shown in Fig. 2(c), where the parabolic shape of the virtual signal can be seen. In addition, the degradation of signals arriving later is evident, as they become more blurred at later measurement times. Fig. 2(c) corresponds to the reconstructed image obtained if only one-dimensional thermographic reconstructions were used. This is only adequate for layered structures, but not for small inclusions. The axial resolution in the z -direction after F-SAFT reconstruction in Fig. 2(d) is the same as for the peaks at a depth of 20, 40, and 80 in Fig. 1. The width of the reconstructed peaks in the y-direction (lateral direction) is approximately twice the width in the axial direction. This effect is known from acoustic reconstruction from limited angle or limited view data39 and can be circumvented by collecting the measurement data not only from one side but also from two sides (called L-reconstruction25) or even more sides.

Fig. 3 shows a three-dimensional example of the thermographic reconstruction of a cube with an edge length of N=48 containing 4 spherical inclusions with the center points at A (N4,N2,N2), B (3N4,N2,N2), C (N2,N4,N4), and D (N2,3N4,3N4). The temperature evolution was calculated in k-space using Eq. (14) at three orthogonal detector planes at the cube surface with z=N (top plane), x=0 (right front plane), and y=0 (left front plane). The three corresponding F-SAFT reconstructions are shown in Figs. 3(b)–3(d), respectively. A SNR of 1000 was chosen for each detector pixel - added as Gaussian noise in this simulation. As the total number of pixels for one detector plane is N2, the truncation value for the truncated SVD is 1/(N2SNR)=1/(NSNR). Therefore, the effective SNR for regularization is NSNR=48000. For all three reconstructions from the three detector planes, limited-view artifacts are visible and the inclusions far from the detector planes cannot be reconstructed at all. Better results could be obtained by using a single reconstruction incorporating data from all three detection surfaces, e.g., by using a time-reversal reconstruction algorithm14 or reconstruction methods from Kunyansky.40 However, as demonstrated in the past, simply taking the sum of the reconstructions from the three detector planes gives similar results and gives a reasonable reconstruction quality,25 which is shown in Fig. 3(e). As mentioned in the introduction, we introduce the name “thermo-tomography” for reconstructions from thermographic signals from several surfaces, in contrast to reconstruction from a single detector plane. Thermo-tomography enables a good reconstruction quality of internal structure in three dimensions.

FIG. 3.

Three-dimensional thermo-tomography: (a) initial temperature distribution T0(x,y,z), consisting of spherical inclusions with the center points A (12,24,24), B (36,24,24), C (24,12,12), and D (24,36,36). (b), (c), and (d) are the F-SAFT reconstructions of the initial temperature distribution for the three detector planes at the cube surface with z=N (top plane), x=0 (right front plane), and y=0 (left front plane), respectively. (e) Reconstruction of the initial temperature distribution T0,rec(x,y,z) as the sum of the values from (b)–(d).

FIG. 3.

Three-dimensional thermo-tomography: (a) initial temperature distribution T0(x,y,z), consisting of spherical inclusions with the center points A (12,24,24), B (36,24,24), C (24,12,12), and D (24,36,36). (b), (c), and (d) are the F-SAFT reconstructions of the initial temperature distribution for the three detector planes at the cube surface with z=N (top plane), x=0 (right front plane), and y=0 (left front plane), respectively. (e) Reconstruction of the initial temperature distribution T0,rec(x,y,z) as the sum of the values from (b)–(d).

Close modal

Two small steel beads (diameter 2 mm, distance 7 mm) were embedded in epoxy at depths z varying between 3–8 mm (see Fig. 4(a)) and heated by a short electromagnetic pulse, which is known as inductive heating or induction thermography. The thermal diffusivity of a neat epoxy sample was obtained by an experimental measurement using the linear diffusivity fitting (LDF) method41 as α=1.3×107m2s. In this experiment, a sample absorbs a short optical energy pulse on the front surface, and the resulting temperature rise at the rear face is analyzed. The measured temperature data is fitted with the solution of the heat conduction equation for the estimation of the thermal diffusivity. The cylindrical test sample was made of an epoxy system, which polymerizes at ambient temperatures when the epoxy resin (SpeciFix resin) reacts with the hardener (SpeciFix – 20 curing agent). The sample was positioned at the center of the induction coil (Fig. 4(b), diameter 80 mm). The distance between the coil and the sample was 20 mm. The induction-heating generator had a nominal output power of 3 kW at a frequency of 220 kHz. For each depth z the total measurement time tmeas=2z2/α was chosen. The total measurement time was determined by the Fourier number Fo=αt/z2. It is a dimensionless number that characterizes the transient heat conduction.42 A Fourier number of Fo=2 ensures that the measurement time is long enough to reach the temperature maximum at the surface of the specimen. In 3D, the temperature maximum occurs at a time tmax=z2/(6α).43 The pulse length was chosen to be 2% of tmeas to approximately resemble a Dirac delta pulse in time, which was the assumption made in Section II. Basing the pulse length and, therefore the pulse energy on z2 ensures that the temperature rise on the epoxy surface is approximately the same for all the samples for different depths z.

FIG. 4.

Experimental set-up: (a) two small steel beads (diameter 2 mm, distance 7 mm) were embedded in an epoxy cylinder with a diameter of 40 mm at a depth z varying between 3–8 mm. (b) The beads were heated by a short pulse by a surrounding induction coil. (c) The surface temperature was measured by an infrared camera at a distance of 235 mm above the epoxy surface.

FIG. 4.

Experimental set-up: (a) two small steel beads (diameter 2 mm, distance 7 mm) were embedded in an epoxy cylinder with a diameter of 40 mm at a depth z varying between 3–8 mm. (b) The beads were heated by a short pulse by a surrounding induction coil. (c) The surface temperature was measured by an infrared camera at a distance of 235 mm above the epoxy surface.

Close modal

The infrared camera (IRcam EQUUS 81 k M pro) was positioned 235 mm above the epoxy sample to keep the influence of the induction coils on the camera low. The size of the resulting pixel was (0.29 × 0.29) mm2. The infrared camera uses an indium antimonite focal plane array (FPA) detector (320 × 256 pixels) which is sensitive to radiation in the 3–5 micron spectral range. In this spectral range, the epoxy material is opaque, and the camera detects only the infrared emission of the surface. The camera has a noise equivalent differential temperature (NEDT) smaller than 20 mK. The integration time was 1 ms. Because of the short pulse time (Table I) and the small beads, the temperature rise on the epoxy surface was about 300 mK (Figs. 5(a)–5(c)). Therefore, the SNR for one camera pixel was only about 15. For the reconstruction, the central NxN pixels of the camera with N=70 have been taken to avoid the effects from side boundaries. This central surface area of 20 mm × 20 mm size is big enough for thermographic measurements. Outside this area, the temperature rise is below the noise level (Figs. 5(a)–5(c)). The truncation value for the smallest singular values is 1/(SNR) (see end of Section II A). For NxN data points (camera pixels) used for the reconstruction, the SNR is enhanced by a factor equal to the square-root of used data points and the effective SNR for regularization is NSNR=1050. The resolution from Eq. (13) is

(15)
TABLE I.

Measurement parameters of the thermographic experiment for the reconstruction of the steel beads at a depth of 3 mm, 6 mm, and 8 mm.

DepthMeasurement timePulse durationFrame rate
(mm)(s)(s)(Hz)
52 25 
208 
371 
DepthMeasurement timePulse durationFrame rate
(mm)(s)(s)(Hz)
52 25 
208 
371 
FIG. 5.

Top Temperature signal from thermographic measurement of two steel beads parallel to the epoxy surface at a depth z of 3 mm (a), 6 mm (b), and 8 mm (c) with the highest signal contrast at times of 7 s, 26 s, and 40 s, respectively. Bottom Thermographic image reconstruction of the two steel beads parallel to the epoxy surface at a depth z of 3 mm (d), 6 mm (e), and 8 mm (f). In (f), the resolution of 7.2 mm is higher than the distance of the beads, and they cannot be resolved. (g) Artifacts come up when more singular values are taken to calculate the pseudo-inverse matrix K+ than allowed by the SNR (see text).

FIG. 5.

Top Temperature signal from thermographic measurement of two steel beads parallel to the epoxy surface at a depth z of 3 mm (a), 6 mm (b), and 8 mm (c) with the highest signal contrast at times of 7 s, 26 s, and 40 s, respectively. Bottom Thermographic image reconstruction of the two steel beads parallel to the epoxy surface at a depth z of 3 mm (d), 6 mm (e), and 8 mm (f). In (f), the resolution of 7.2 mm is higher than the distance of the beads, and they cannot be resolved. (g) Artifacts come up when more singular values are taken to calculate the pseudo-inverse matrix K+ than allowed by the SNR (see text).

Close modal

Figs. 5(d)–5(f) show the reconstructions at depths of the steel beads z of 3 mm, 6 mm, and 8 mm. The resolution according to Eq. (15) is 2.7 mm, 5.4 mm, and 7.2 mm, respectively. As the distance of the two beads is 7 mm, they cannot be resolved in (f). Artifacts come up when more singular values are taken to calculate the pseudo-inverse than allowed by the SNR. Using 15 singular values would correspond to an SNR of 7000 instead of the 12 singular values corresponding to the actual effective SNR of 1050. This gives a better resolution according to Eq. (15) of 5.7 mm, and the two beads can still be resolved as shown in Fig. 5(g). However, additional artifacts come up because of the influence of the fluctuations. The corresponding measurement parameters are listed in Table I.

The same experimental set-up as in Fig. 4 was used to measure the thermographic signals from four spherical steel beads with a diameter of 2 mm, which were embedded in an epoxy cube with an edge length of 15 mm (see Fig. 6(a)). The geometry corresponds to the simulation shown in Fig. 3. The epoxy material, the steel beads, the inductive heating, and the position of the sample between the coils were the same as in Section A. Only the distance between the front lens of the infrared camera and the sample surface was reduced to 95 mm to achieve 140 pixels for the cube edge length of 15 mm (Fig. 6(b)). The bottom and the sidewalls of the cube were thermally isolated using polystyrene foam to ensure adiabatic boundary conditions (Fig. 6(c)). The temperature evolutions on the front plane, the top plane, and the left side plane were measured and used for tomographic reconstruction. As the steel beads had depths z of approximately 4.3 mm, 7.5 mm, and 10.7 mm from the measurement planes, it was not possible to adjust the pulse times for every individual depth as in Section A. The pulse time 7.5 s was chosen to obtain thermographic signals from the deeper beads. For the bead at a depth of 4.3 mm, the maximum of the thermographic signal is at a time tmax of 23.7 s. Therefore, for this bead, the pulse time is nearly one third of tmax, and the assumption of the Dirac delta pulse excitation is only approximately valid any more. Using this Dirac delta pulse excitation assumption, the reconstruction in Fig. 7 still works well, but the position is slightly shifted to higher depths.

FIG. 6.

Experimental set-up for 3D thermo-tomography: (a) 4 spherical steel beads (diameter 2 mm) were embedded in an epoxy cube with an edge length of 15 mm as in the simulations shown in Fig. 3(a). The front plane, the top plane, and the left side plane were measured and used for tomographic reconstruction. (b) Measurement set-up similar to Fig. 4, only the distance of the infrared camera was reduced to 95 mm to achieve 140 pixels for the edge length of the cube (9.33 pixels per mm). The camera was therefore protected by a metal sheet from the influence of the induction coils. (c) The bottom and the sidewalls of the cube were thermally isolated using polystyrene foam to ensure adiabatic boundary conditions.

FIG. 6.

Experimental set-up for 3D thermo-tomography: (a) 4 spherical steel beads (diameter 2 mm) were embedded in an epoxy cube with an edge length of 15 mm as in the simulations shown in Fig. 3(a). The front plane, the top plane, and the left side plane were measured and used for tomographic reconstruction. (b) Measurement set-up similar to Fig. 4, only the distance of the infrared camera was reduced to 95 mm to achieve 140 pixels for the edge length of the cube (9.33 pixels per mm). The camera was therefore protected by a metal sheet from the influence of the induction coils. (c) The bottom and the sidewalls of the cube were thermally isolated using polystyrene foam to ensure adiabatic boundary conditions.

Close modal
FIG. 7.

Reconstruction results for 3D thermo-tomography: (a) sum of the reconstructions from top plane, left front, and left back plane measurements. Due to the poor SNR (see text) only the steel beads near the measurement planes at a distance of 4.3 mm (approximately 40 pixels) could be reconstructed. Due to limited view artifacts (see also Fig. 2), the lateral resolution is worse than the axial resolution (ellipsoidal shape), and this effect is not reduced by adding reconstructions from other measurement planes, because the resolution is too bad for the other measurements to have a significant influence. (b) Filtering the measurement data (see text) before reconstruction allows the reconstruction of the fourth steel bead, and the artifacts due to limited view are better compensated.

FIG. 7.

Reconstruction results for 3D thermo-tomography: (a) sum of the reconstructions from top plane, left front, and left back plane measurements. Due to the poor SNR (see text) only the steel beads near the measurement planes at a distance of 4.3 mm (approximately 40 pixels) could be reconstructed. Due to limited view artifacts (see also Fig. 2), the lateral resolution is worse than the axial resolution (ellipsoidal shape), and this effect is not reduced by adding reconstructions from other measurement planes, because the resolution is too bad for the other measurements to have a significant influence. (b) Filtering the measurement data (see text) before reconstruction allows the reconstruction of the fourth steel bead, and the artifacts due to limited view are better compensated.

Close modal

The sampling rate of the camera was chosen at 10 Hz, and the distance to the cube surface was reduced to 95 mm to obtain more pixels for the reconstruction (N=140, Fig. 6(b)). The SNR for the thermographic signals was about 90, which gave an effective SNR for the regularization with NSNR=12600. For shorter pulse times, the SNR was worse. This SNR is sufficient to achieve a good reconstruction of the steel beads near the measurement planes at a depth of 4.3 mm (approximately 40 pixels), shown in Fig. 7(a). To avoid limiting-view artifacts (ellipsoidal shape of the reconstructed spheres) in thermo-tomography, a higher SNR is necessary. This is different from the limiting-view artifacts in pure acoustic imaging, where the acoustic signals are not attenuated and the measurement signals from other projection directions always reduce the limiting view artifacts. The knowledge, that the first bead is at a depth of 4.3 mm, gives a truncation frequency of 0.045 Hz using Eq. (11). This truncation frequency was used as the cutoff frequency of a 6th-order low-pass Butterworth filter, which significantly increased the SNR of the filtered measurement signals to 1340, resulting in an effective SNR for the regularization with NSNR=187600. Filtering the measurement data does not affect the reconstructions at a higher depth than 4.3 mm, because the truncation frequency according to Eq. (11) is less than 0.045 Hz. The reconstruction from the filtered data is shown in Fig. 7(b). Now, a contour level could be found where the bead A is also reconstructed, and the artifacts due to limited view are better compensated. For both figures in Fig. 7, the contour level is the maximum level divided by the Eulers number, e.

In the presented work, signal reconstruction for short excitation pulses was demonstrated. In the future work, the concept of virtual waves will be transferred to other excitation schemes, including longer pulses, frequency-domain excitation with a single-frequency, or chirped pulses. For simplicity, in this work, internal metallic structures were directly heated by using an induction coil. In future, this method will be extended to heating the surface of opaque samples directly by the excitation pulse. The generated heat then diffuses into the sample, and this diffusion will be influenced by the internal structures. Virtual waves can also be used for image reconstruction in this case. However, it is expected that the resolution limit will be twice the limit given in Eq. (13), as the heat has to diffuse from the surface to the internal structures and back again. Direct and indirect heating can be seen as the thermographic equivalent of photoacoustic imaging and laser ultrasonics. In photoacoustic imaging, ultrasonic waves are generated in internal structures by means of laser irradiation, whereas in laser ultrasonics, the ultrasonic waves generated at a sample surface are scattered by the internal structures.14,44 For both cases, F-SAFT reconstruction can be used. In laser ultrasonics, the propagation distances have to be doubled compared to photoacoustics, or alternatively, half of the sound velocity is taken.24 Also, boundary conditions for the sample surface which are more realistic than the adiabatic boundary condition should be investigated in future. First results for a third kind boundary condition43 are given in Burgholzer et al.34 Another assumption made in this publication, which can be changed in future work is the homogeneous thermal diffusivity. For small and well-separated structures of different materials, like the small steel beads used in the presented work, the thermal surface signal is only slightly changed in comparison to a strictly homogeneous material. In the case of more inhomogeneous areas within the sample, a virtual wave concept with inhomogeneous sound velocity seems feasible to reconstruct the initial temperature distribution.

Beyond thermography, this work might lead to a better understanding of ill-posed inverse problems and the physical background of regularization. Thermodynamic fluctuations are usually only relevant for macroscopic samples, but for ill-posed inverse problems, they become highly amplified. This is the reason why information is lost in the direct forward problem and cannot be retrieved in the inverse problem. We have shown before that the lost information, quantitatively described by the Kullback-Leibler divergence (see  Appendix), is equal to the entropy production.36 As known from thermodynamics, the direct forward process always shows an entropy increase and, therefore, the inverse problem has to be ill-posed. The lost information is just the produced entropy. Only for ideal, reversible processes is no entropy produced and, therefore, the inverse problem is well-posed and can be solved without regularization.

In the proposed method, all the irreversibility of the heat diffusion is contained in the transformation from T to Tvirt. The information loss during this transformation, which correlates with a reduced spatial resolution of the reconstructed images, is equal to the entropy production caused by the diffusion. This information loss causes a fundamental resolution limit for the reconstructed images that cannot be compensated by any reconstruction algorithm. As reviewed in  Appendix and shown in Section II B for the case of a short pulse, ideally a Dirac delta pulse, the best reconstruction results can be obtained in the temporal frequency domain by using frequencies up to a truncation frequency ωtrunc. At this frequency, the “thermal wave” is damped just to the noise level.

For imaging sub-surface structures by means of pulsed thermography, the temperature distribution inside the sample has to be reconstructed from the temperature evolution measured on the sample surface. Instead of directly solving this ill-posed inverse problem, a two-stage algorithm was presented. First, a virtual signal is calculated from the measured temperature evolution for every detection point. This virtual signal is a solution of the wave equation with the same initial conditions as the heat diffusion equation. In contrast to the measured temperature evolution, the virtual signal can be reversed in time, and all well-established reconstruction methods known from ultrasound imaging can be used for thermographic reconstruction in a second step. The main advantage of the proposed two-stage algorithm over directly solving the inverse heat diffusion problem is that the local transformation introduced is the same for all sample geometries and dimensions. In the second step, standard procedures from ultrasonic imaging can be used.

The feasibility of this approach was demonstrated through simulations and experiments. In the experiments, steel beads embedded in an epoxy matrix were heated by a short electromagnetic pulse generated by a surrounding induction coil. The temperature evolution on the surface was then measured using an infrared camera in the spectral region between 3 and 5 μm. The obtained resolution limit turned out to be proportional to the depth of the structures and to be inversely proportional to the natural logarithm of the signal-to-noise ratio. In two and three dimensions, the lateral resolution can be degraded due to limited view artefacts if the temperature evolution is measured on one surface only. By acquiring the temperature data on more than one surface, the resolution and quality of thermographic reconstructions can be enhanced. This effect was demonstrated in numerical simulations and by experiment. For the latter, the temperature evolution caused by the inductive heating of four steel beads was measured on three orthogonal surfaces of an epoxy cube.

Thermographic imaging using an infrared camera for signal detection has a big advantage compared to ultrasonic imaging using acoustic transducers: it does not need any coupling media and parallel detection of many camera pixels is possible. The main disadvantage of pulsed thermography is the degrading spatial resolution with an increasing depth. This is the reason why often only one-dimensional thermographic reconstruction is performed, which can be applied for layered structures, where the lateral extension is big compared to their depth. For other structures, using a one-dimensional reconstruction gives additional artifacts, as the heat propagates not only perpendicular to the surface but also in the lateral direction. Solving directly the inverse three-dimensional heat diffusion equation is rather ambitious, even for simple geometries of embedded structures, e.g., rectangular vertical cracks.7 Three-dimensional reconstruction methods, which are well known for ultrasonic imaging, can be used easily for any sample geometry by applying the proposed virtual wave concept.

This work has been supported by the Christian Doppler Research Association (Christian Doppler Laboratory for Photoacoustic Imaging and Laser Ultrasonics), and by the project “multimodal and in-situ characterization of inhomogeneous materials” (MiCi) by the federal government of Upper Austria and the European Regional Development Fund (EFRE) in the framework of the EU-program IWB2020. This work was also financially supported by the TAKE OFF program of the Bundesministerium fuer Verkehr, Innovation und Technologie (BMVIT) and by the strategic economic-research program “Innovative Upper Austria 2020” of the province of Upper Austria. We thank Heinz Gresslehner, Thomas Berer, and Todd Murray for inspiring discussions and useful comments.

In this  Appendix, the main results from our work in the past on the connection of entropy production, information loss, and time reversal of heat diffusion are shortly reviewed17,34–36 which are used in Section II B. In the past, rank deficient and discrete ill-posed problems like the inversion of Eq. (10) have been examined in many mathematical publications. E.g., Hansen33 gives a good introduction and an overview about the numerical aspects of linear inversion. If one is interested only in the application of virtual wave signals for thermographic reconstruction, one of these regularization methods can be used. But the choice of the optimal regularization method and of the regularization parameter is still a matter of discussion. Therefore, we have investigated in the past why the inversion of heat diffusion is ill-posed and give a short review of the results in this  Appendix. The implications on the spatial resolution for thermographic reconstruction are discussed.

Temperature in thermodynamics describes the mean kinetic energy of the molecules and can be modeled in statistical physics as a random variable showing fluctuations about its mean value.45 In macroscopic systems, these fluctuations are extremely small, but they are highly amplified in ill-posed inverse problems like heat diffusion and, therefore, thermodynamic fluctuations get significant. Despite the time invariance of the dynamics of the individual molecules, the time evolution of temperature shows a direction of time, which is described by increasing entropy in the second law of thermodynamics. To take the influence of fluctuations and entropy production on thermographic reconstruction into account, we have modeled heat diffusion as a stochastic process (Ornstein – Uhlenbeck process as a Gauss – Markov process) and found that the information loss is equal to the production of entropy during heat diffusion.35 Fluctuations and entropy production are closely connected, and we showed the equality of entropy production, and information loss is equivalent to a fluctuation-dissipation theorem, which represents a generalization of the famous Johnson46–Nyquist47 formula in the theory of electric noise.

Of course, modeling heat diffusion by a simple Gauss-Markov process is a rough idealization. Nevertheless, for macroscopic systems, we could show the equality of entropy production and information loss from recent results of non-equilibrium statistical physics, where we only used the heat diffusion equation modeling the mean value evolution of the temperature without the necessity to describe the fluctuations.36 The influence of fluctuations is implicitly taken into account by calculating the entropy production from the mean value equation as a simple linear differential equation, and no sophisticated stochastic process has to be used. As the mean entropy production during the process, which is always positive, is equal to the information loss, the reconstruction of an earlier state from a later state of the process has to be an ill-posed problem. Any reconstruction algorithm cannot gain the lost information. Why does this information loss result in a degradation of the reconstructed image? High-resolution images contain more information than those with low spatial resolution, which is evident, for e.g., when they are stored on a computer - they need more memory capacity. During heat diffusion, a sharp pulse, ideally a Dirac delta pulse, which provides high resolution and contains all frequency components in temporal frequency domain and therefore much information, will be blurred and broadened according to Eq. (9). As the resolution limit is the size of a small (ideally point-like) reconstructed structure at a certain depth, this pulse broadening limits the spatial resolution. This broadening can be compensated by an inversion only up to a certain extent limited by the information loss. The information lost due to fluctuations, which is for macroscopic samples equal to the entropy production, cannot be compensated by any reconstruction algorithm, and causes a principle resolution limit for the reconstructed images.

This qualitative description of the degradation of the reconstructed image due to heat diffusion can be formulated quantitatively by using the relative entropy, called also as Kullback – Leibler (KL) divergence,48 to measure the information content of a thermographic signal. The KL divergence D(f||g) is used in the information theory for testing the hypothesis that the two distributions with density f and g are different, and is defined as

(A1)

where ln is the natural logarithm. The Chernoff – Stein Lemma states that if n data generated from a distribution density g are given, the probability of guessing incorrectly that the distribution density for describing the data is f is bounded by the type II error ϵexp(nD(f||g)), for n large.48 In that sense D(f||g) can describe a “distance” between the distribution densities f and g.

In thermal equilibrium with distribution density peq in the state space, the whole sample is on the same temperature. The entropy has its maximum, and all the information for a thermographic reconstruction has been lost. At what time ttrunc is the equilibrium reached? At a certain time t the state with distribution density pt contains the information kBD(pt||peq), where kB is the Boltzmann's constant, and for the macroscopic system, this is equal to the entropy production between the state at time t and the equilibrium state.36 From Chernoff – Stein Lemma it is known that if D(pt||peq) gets smaller than a certain level ln(1ϵ)/n the state cannot be distinguished from equilibrium. Therefore at any time later than this truncation time ttrunc thermal equilibrium is reached. ttrunc depends on the type II error ϵ.

In the temporal frequency domain (ω-space), a truncation frequency ωtrunc is used instead of the truncation time. The information content kBD(pω(r)||peq) of the diffusion signal with frequency ω at distance r is equal to the entropy production36,45

(A2)

with the signal-to-noise ratio SNR. The truncation frequency ωtrunc is determined according to the Chernoff – Stein Lemma when ΔSω(r) gets smaller than kBln(1ϵ)/n:

(A3)

where C:=2ln(1ϵ)/n is a constant value containing the error level ϵ and the number of measurements n, which scales the SNR. Choosing this constant value C equal to one means that the amplitude for this “thermal wave” with frequency ωtrunc is damped at a distance r by the exponential factor exp(rωtrunc/2α) just to the noise level (Fig. 8) and leads to Eq. (11) in Section II B.

FIG. 8.

Thermographic signal in ω – space: θ(r,ω) is damped by exp(rω2α) at a distance r. The amplitude with frequency ωtrunc is damped just to the noise level. For reconstruction only, the frequencies less than ωtrunc are taken.

FIG. 8.

Thermographic signal in ω – space: θ(r,ω) is damped by exp(rω2α) at a distance r. The amplitude with frequency ωtrunc is damped just to the noise level. For reconstruction only, the frequencies less than ωtrunc are taken.

Close modal
1.
X. P. V.
Maldague
,
Theory and Practice of Infrared Thermography for Nondestructive Testing
(
John Wiley & Sons
,
New York
,
2001
).
2.
C.
Meola
and
G. M.
Carlomagno
,
Meas. Sci. Technol.
15
,
R27
(
2004
).
3.
J.
Ravi
,
Y.
Lu
,
S.
Longuemart
,
S.
Paoloni
,
H.
Pfeiffer
,
J.
Thoen
, and
C.
Glorieux
,
J. Appl. Phys.
97
,
014701
(
2005
).
4.
C.
Glorieux
,
R.
Li Voti
,
J.
Thoen
,
M.
Bertolotti and
, and
C.
Sibilia
,
Inverse Probl.
15
,
1149
(
1999
).
5.
L.
Vidovic
,
M.
Milanic
, and
B.
Majaron
,
J. Biomed. Opt.
20
,
017001
(
2015
).
6.
T.
Milner
,
D.
Goodman
,
B.
Tanenbaum
, and
J.
Nelson
,
J. Opt. Soc. Am. A
12
,
1479
(
1995
).
7.
A.
Mendioroz
,
R.
Celorrio
, and
A.
Salazar
,
Rev. Sci. Instrum.
86
,
064903
(
2015
).
8.
U.
Netzelmann
,
G.
Walle
,
S.
Lugin
,
A.
Ehlen
,
S.
Bessert
, and
B.
Valeske
,
QIRT J.
13
,
170
(
2016
).
9.
V. P.
Vavilov
and
D. D.
Burgleigh
,
NDT&E Int.
73
,
28
(
2015
).
10.
G.
Busse
,
D.
Wu
, and
W.
Karpen
,
J. Appl. Phys.
71
,
3962
(
1992
).
11.
X.
Maldague
and
S.
Marinetti
,
J. Appl. Phys.
79
,
2694
(
1996
).
12.
G.
Busse
,
Appl. Phys. Lett.
35
,
759
(
1979
).
13.
S.
Kaiplavil
and
A.
Mandelis
,
Nat. Photonics
8
,
635
(
2014
).
14.
P.
Burgholzer
,
G. J.
Matt
,
M.
Haltmeier
, and
G.
Paltauf
,
Phys. Rev. E
75
,
046706
(
2007
).
15.
16.
D.
Modgil
,
B. E.
Treeby
, and
P. J.
La Riviere
,
J. Biomed. Opt.
17
,
061204
(
2012
).
17.
P.
Burgholzer
,
H.
Roitner
,
J.
Bauer-Marschallinger
,
H.
Gruün
,
T.
Berer
, and
G.
Paltauf
,
Acoustic Waves—From Microdevices to Helioseismology
, edited by
M. G.
Beghi
(
InTech
,
2011
).
18.
P. J.
La Riviere
,
J.
Zhang
, and
M. A.
Anastasio
,
Opt. Lett.
31
,
781
(
2006
).
19.
M.
Xu
and
L. V.
Wang
,
Rev. Sci. Instrum.
77
,
041101
(
2006
).
20.
A.
Rosenthal
,
D.
Razansky
, and
V.
Ntziachristos
,
IEEE Trans. Med. Imaging
29
,
1275
(
2010
).
21.
Y.
Xu
and
L.-H. V.
Wang
,
Phys. Rev. Lett.
92
,
033902
(
2004
).
22.
B. E.
Treeby
and
B. T.
Cox
,
J. Biomed. Opt.
15
,
021314
(
2010
).
23.
L. J.
Busse
,
IEEE Trans. UFFC
39
,
174
(
1992
).
24.
D.
Lévesque
,
A.
Blouin
,
C.
Néron
, and
J.-P.
Monchalin
,
Ultrasonics
40
,
1057
(
2002
).
25.
P.
Burgholzer
,
T.
Berer
,
B.
Reitinger
,
R.
Nuster
, and
G.
Paltauf
,
J. Acoust. Soc. Am.
123
,
3156
(
2008
); See also in Proceedings of 1st International Symposium on Laser Ultrasonics: Science, Technology, and Applications, Montreal, QC, Canada, 16–18 July 2008.
26.
A.
Gleiter
and
G.
Mayr
,
Infrared Phys. Technol.
53
,
288
(
2010
).
27.
H.
Ammari
,
Mathematical Modeling in Biomedical Imaging II
(
Springer
,
Berlin, Heidelberg
,
2012
).
28.
H. S.
Carslaw
and
J. C.
Jaeger
,
Conduction of Heat in Solids
(
Clarendon Press.
,
Oxford
,
1959
).
29.
J.
Ordonez-Miranda
,
R.
Yang
,
S.
Volz
, and
J. J.
Alvarado-Gil
,
J. Appl. Phys.
118
,
075103
(
2015
).
30.
K. P.
Köstli
,
D.
Frauchinger
,
J.
Niederhauser
,
G.
Paltauf
,
H.
Weber
, and
M.
Frenz
,
IEEE J. Sel. Top. Quantum Electron.
7
,
918
(
2001
).
31.
M.
Xu
and
L.-H. V.
Wang
,
IEEE Trans. Med. Imaging
21
,
814
(
2002
).
32.
H. R. B.
Orlande
,
O.
Fudym
,
D.
Maillet
, and
R. M.
Cotta
,
Thermal Measurements and Inverse Techniques
(
CRC Press
,
Boca Raton
,
2011
).
33.
P. C.
Hansen
,
Rank-Deficient and Discrete Ill-Posed Problems: Numerical Aspects of Linear Inversion
(
SIAM
,
Philadelphia
,
1987
).
34.
P.
Burgholzer
,
F.
Camacho-Gonzales
,
D.
Sponseiler
,
G.
Mayer
, and
G.
Hendorfer
, “Information changes and time reversal for diffusion-related periodic fields,” in
Biomedical Optics: Photons Plus Ultrasound: Imaging and Sensing
(
SPIE
,
2009
) p.
7177
.
35.
P.
Burgholzer
and
G.
Hendorfer
,
Int. J. Thermophys.
34
,
1617
(
2013
).
36.
P.
Burgholzer
,
Int. J. Thermophys.
36
,
2328
(
2015
).
37.
M. J.
Buckingham
,
Phys. Rev. E
72
,
026610-1
(
2005
).
38.
P.
Burgholzer
,
F.
Camacho-Gonzales
,
D.
Sponseiler
,
G.
Mayr
, and
G.
Hendorfer
,
Proc. SPIE
7177
,
76
(
2009
).
39.
G.
Paltauf
,
R.
Nuster
,
M.
Haltmeier
, and
P.
Burgholzer
,
Inverse Probl.
23
,
S81
(
2007
).
40.
L. A.
Kunyansky
,
Inverse Probl.
23
,
S11
(
2007
).
41.
G.
Mayr
,
B.
Plank
,
J.
Sekelja
, and
G.
Hendorfer
,
NDTE Int.
44
,
537
(
2011
).
42.
F. P.
Incropera
,
D. P.
Dewitt
,
T. L.
Bergmann
, and
A. S.
Lavine
,
Fundamentals of Heat and Mass Transfer
(
John Wiley & Sons
,
Hoboken
,
2007
).
43.
A.
Mandelis
,
Diffusion-Wave Fields: Mathematical Methods and Green Functions
(
Springer
,
New York
,
2001
).
44.
A. P.
Jathoul
,
J.
Laufer
,
O.
Ogunlade
,
B.
Treeby
,
B.
Cox
,
E.
Zhang
,
P.
Johnson
,
A. R.
Pizzey
,
B.
Philip
,
T.
Marafioti
,
M. F.
Lythgoe
,
R. B.
Pedley
,
M. a.
Pule
, and
P.
Beard
,
Nat. Photonics
9
,
239
(
2015
).
45.
S. R.
de Groot
and
P.
Mazur
,
Non-Equilibrium Thermodynamics
(
Dover Publications
,
New York
,
1984
).
46.
J. B.
Johnson
,
Phys. Rev.
32
,
97
(
1928
).
47.
48.
T. M.
Cover
and
J. A.
Thomas
,
Elements of Information Theory
, 2nd ed. (
Wiley
,
New York
,
2006
).