Interlaboratory comparison of positron annihilation lifetime measurements using synthetic fused silica and polycarbonate was conducted with the participation of 12 laboratories. By regulating procedures for the measurement and data analysis the uncertainties of the positron lifetimes obtained at different laboratories were significantly reduced in comparison with those reported in the past.

1.
Positron Solid-State Physics
, edited by
W.
Brandt
and
A.
Dupasquier
(
North-Holland
,
Amsterdam
,
1983
).
2.
O. E.
Mogensen
,
Positron and Positronium Chemistry
(
Springer
,
Berlin
,
1995
).
3.
Positron Annihilation in Semiconductors: Defect Studies
, edited by
R.
Krause-Rehberg
and
H. S.
Leipner
(
Springer
,
Berlin
,
2003
).
4.
S. J.
Tao
,
J. Chem. Phys.
56
,
5499
(
1972
).
5.
M.
Eldrup
,
D.
Lightbody
, and
J. N.
Sherwood
,
Chem. Phys.
63
,
51
(
1981
).
6.
K.
Ciesielski
,
A. L.
Dawidowicz
,
T.
Goworek
,
B.
Jasińska
, and
J.
Wawryszczuk
,
Chem. Phys. Lett.
289
,
41
(
1998
).
7.
K.
Ito
,
H.
Nakanishi
, and
Y.
Ujihira
,
J. Phys. Chem. B
103
,
4555
(
1999
).
8.
D. W.
Gidley
,
W. E.
Frieze
,
T. L.
Dull
,
A. F.
Yee
,
E. T.
Ryan
, and
H. -M.
Ho
,
Phys. Rev. B
60
,
R5157
(
1999
).
9.
C.
Wästlund
,
M.
Eldrup
, and
F. H. J.
Maurer
,
Nucl. Instrum. Methods Phys. Res. B
143
,
575
(
1998
).
10.
R. D.
Goldberg
,
A. P.
Knights
,
P. J.
Simpson
, and
P. G.
Coleman
,
J. Appl. Phys.
86
,
342
(
1999
).
11.
H.
Saito
,
Y.
Nagashima
,
T.
Kurihara
, and
T.
Hyodo
,
Nucl. Instrum. Methods Phys. Res. A
487
,
612
(
2002
).
12.
This does not mean that a lower signal-to-noise ratio (S/N) is preferable. Rather, it means that the background level should be larger than 15 irrespective of S/N.
13.
T.
Chang
,
D.
Yin
,
C.
Cao
,
S.
Wang
, and
J.
Liang
,
Nucl. Instrum. Methods Phys. Res. A
256
,
398
(
1987
).
14.
H.
Saito
and
T.
Hyodo
,
Mater. Sci. Forum
445–446
,
457
(
2004
).
16.
All the PMTs were from Hamamatsu Photonics K.K., Japan.
You do not currently have access to this content.