In the second paragraph of “Theoretical calculation of the pressure and shear stress in the deformed macrochannel” in “RESULTS AND DISCUSSION,”1 the text “Due to the cell culture medium container connecting to the atmosphere, (Pout) at the outlet of the deformed macrochannel can be calculated from the pressure drop of the tubes connecting the outlet to the container, which concludes the pressure head loss (ΔPguide) in a narrow guide rectangular microchannel and that singledollar (ΔPextended) singledollar in an extended outflow round duct, …” should be corrected to “Due to the cell culture medium container connecting to the atmosphere, the pressure (Pout) at the outlet of the deformed macrochannel can be calculated from the pressure drop of the tubes connecting the outlet to the container, which concludes the pressure head loss (ΔPguide) in a narrow guide rectangular microchannel and the pressure head loss (ΔPextended) in an extended outflow round duct, ….”.
Erratum|
September 13 2023
Erratum: “Microfluidic-to-macrofluidic: A simple in vitro model of atherosclerosis induced by fluidic stimulation” [Biomicrofluidics 17, 044106 (2023)]
Jingang Cui
;
Jingang Cui
1
College of Life Sciences, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Wei Jiang
;
Wei Jiang
1
College of Life Sciences, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Jilei Su
;
Jilei Su
1
College of Life Sciences, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Jiazhen Zhang;
Jiazhen Zhang
1
College of Life Sciences, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Yongliang Yu;
Yongliang Yu
a)
2
School of Engineering Science, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Yongsheng Ding
Yongsheng Ding
a)
1
College of Life Sciences, University of Chinese Academy of Sciences
, Beijing 100049, China
Search for other works by this author on:
Biomicrofluidics 17, 059901 (2023)
Article history
Received:
August 31 2023
Accepted:
August 31 2023
Connected Content
Citation
Jingang Cui, Wei Jiang, Jilei Su, Jiazhen Zhang, Yongliang Yu, Yongsheng Ding; Erratum: “Microfluidic-to-macrofluidic: A simple in vitro model of atherosclerosis induced by fluidic stimulation” [Biomicrofluidics 17, 044106 (2023)]. Biomicrofluidics 1 September 2023; 17 (5): 059901. https://doi.org/10.1063/5.0174489
Download citation file: