Integrating different steps on a chip for cell manipulations and sample preparation is of foremost importance to fully take advantage of microfluidic possibilities, and therefore make tests faster, cheaper and more accurate. We demonstrated particle manipulation in an integrated microfluidic device by applying hydrodynamic, electroosmotic (EO), electrophoretic (EP), and dielectrophoretic (DEP) forces. The process involves generation of fluid flow by pressure difference, particle trapping by DEP force, and particle redirect by EO and EP forces. Both DC and AC signals were applied, taking advantages of DC EP, EO and AC DEP for on-chip particle manipulation. Since different types of particles respond differently to these signals, variations of DC and AC signals are capable to handle complex and highly variable colloidal and biological samples. The proposed technique can operate in a high-throughput manner with thirteen independent channels in radial directions for enrichment and separation in microfluidic chip. We evaluated our approach by collecting Polystyrene particles, yeast cells, and E. coli bacteria, which respond differently to electric field gradient. Live and dead yeast cells were separated successfully, validating the capability of our device to separate highly similar cells. Our results showed that this technique could achieve fast pre-concentration of colloidal particles and cells and separation of cells depending on their vitality. Hydrodynamic, DC electrophoretic and DC electroosmotic forces were used together instead of syringe pump to achieve sufficient fluid flow and particle mobility for particle trapping and sorting. By eliminating bulky mechanical pumps, this new technique has wide applications for in situ detection and analysis.
Skip Nav Destination
Article navigation
March 2013
Research Article|
March 20 2013
High-throughput particle manipulation by hydrodynamic, electrokinetic, and dielectrophoretic effects in an integrated microfluidic chip
Shunbo Li;
Shunbo Li
1
Department of Physics and KAUST-HKUST joint Micro/Nanofluidic Laboratory, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
Ming Li;
Ming Li
2
School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong
, Wollongong 2522, New South Wales, Australia
Search for other works by this author on:
Kristelle Bougot-Robin;
Kristelle Bougot-Robin
3
Institute for Advanced Study, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
Wenbin Cao;
Wenbin Cao
4
Nano Science and Technology Program and Department of Physics, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
Irene Yeung Yeung Chau;
Irene Yeung Yeung Chau
4
Nano Science and Technology Program and Department of Physics, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
Weihua Li;
Weihua Li
2
School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong
, Wollongong 2522, New South Wales, Australia
Search for other works by this author on:
Weijia Wen
Weijia Wen
a)
1
Department of Physics and KAUST-HKUST joint Micro/Nanofluidic Laboratory, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
4
Nano Science and Technology Program and Department of Physics, The Hong Kong University of Science and Technology
, Clear Water Bay, Kowloon, Hong Kong
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Electronic mail: phwen@ust.hk.
Biomicrofluidics 7, 024106 (2013)
Article history
Received:
January 25 2013
Accepted:
March 07 2013
Citation
Shunbo Li, Ming Li, Kristelle Bougot-Robin, Wenbin Cao, Irene Yeung Yeung Chau, Weihua Li, Weijia Wen; High-throughput particle manipulation by hydrodynamic, electrokinetic, and dielectrophoretic effects in an integrated microfluidic chip. Biomicrofluidics 1 March 2013; 7 (2): 024106. https://doi.org/10.1063/1.4795856
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00
Citing articles via
Related Content
Electrokinetic framework of dielectrophoretic deposition devices
J. Appl. Phys. (June 2010)
Modelling of electrokinetic phenomena for capture of PEGylated ribonuclease A in a microdevice with insulating structures
Biomicrofluidics (June 2016)
Electrokinetic focusing and filtration of cells in a serpentine microchannel
Biomicrofluidics (November 2009)
Surface-conduction enhanced dielectrophoretic-like particle migration in electric-field driven fluid flow through a straight rectangular microchannel
Physics of Fluids (October 2017)
Impacts of low concentration surfactant on red blood cell dielectrophoretic responses
Biomicrofluidics (September 2019)