A new type of quantum interferometer was recently realized that employs parametric amplifiers (PAs) as the wave splitting and mixing elements. The quantum behavior stems from the PAs, which produce quantum entangled fields for probing the phase change signal in the interferometer. This type of quantum entangled interferometer exhibits some unique properties that are different from traditional beam splitter-based interferometers such as Mach–Zehnder interferometers. Because of these properties, it is superior to the traditional interferometers in many aspects, especially in the phase measurement sensitivity. We will review its unique properties and applications in quantum metrology and sensing, quantum information, and quantum state engineering.
I. INTRODUCTION
Interferometry, a technique based on wave interference, played a crucial part in the development of fundamental ideas in physics as well as in the technological advances of mankind. It has become an indispensable part in precision measurement and metrology ever since its inception. Most of the physical quantities such as distance, local gravity fields, and magnetic fields that can be measured by the interferometric technique are associated with the phases of the interfering waves. It is the extreme sensitiveness to the phase change in interferometry that leads to wide applications of the technique in precision measurement and metrology.
In traditional interferometry, as shown in Fig. 1(a), an input field is split into two by a beam splitter (BS1). One of the beams, serving as the probe, is phase modulated so as to encode a phase change (δ) onto it. It then interferes with the other beam, serving as a reference, at another beam splitter (BS2). This converts the phase change to an intensity change, and the outputs of BS2 are directly measured and analyzed with intensity detectors. Regardless of the difference in design between different schemes, the sensitivity of traditional interferometers is limited by the vacuum quantum noise or the so-called shot noise inherited from the input field and the vacuum field injected from the unused BS input ports1 [dashed line in Fig. 1(a)]. The sensitivity limit of this kind of interferometer is referred to as the shot noise limit (SNL) or sometimes the standard quantum limit (SQL), i.e., the general -dependence at a large phase sensing photon number N. In order to reduce the vacuum quantum noise, squeezed states are properly injected into interferometers by replacing the vacuum state.1 The result of the squeezed state injection is the reduction of the detection noise below the shot noise level and thus the enhancement of phase measurement sensitivity. Experimental efforts and progress were made in the generation and application of these quantum states to optical interferometry systems.2,3 In fact, such a technique was recently applied to km-scale large size interferometers with the goal of improving the sensitivity for gravitational wave detection.4–6
Comparison between (a) a traditional Mach–Zehnder interferometer and (b) an SU(1,1) interferometer.
Comparison between (a) a traditional Mach–Zehnder interferometer and (b) an SU(1,1) interferometer.
SU(1,1) interferometers are a new type of quantum interferometers, which are quite different from the traditional interferometers in that the linear beam splitters are replaced by nonlinear optical devices of parametric amplifiers (PAs), as shown in Fig. 1(b). The name of SU(1,1) stems from the type of interaction involved in parametric processes for nonlinear wave mixing, which is different from the SU(2)-type interaction for linear wave mixing by a beam splitter. SU(1,1) interferometers were first proposed by Yurke et al.7 to reach the Heisenberg limit (HL), i.e., the general 1/N-dependence at a large phase sensing photon number N. This is the ultimate quantum limit8 in precision phase measurement at large N although it can be broken9 at small N. However, the original version is not practical because it starts with vacuum and thus has a low photon number. That is why there was no experimental implementation until recently when a modified version with a photon number boost by coherent state injection was proposed,10,11 which has since been realized in atomic four-wave mixing,12–15 bulk χ(2)-nonlinear medium,16 and nonlinear optical fiber.17–19 In the meanwhile, theoretical investigations on SU(1,1) interferometers were also carried out for various input states and different measurement strategies20–22 and were based on quantum Fisher information, leading to the quantum Cramer–Rao bound.21,23–26
The difference between SU(1,1) interferometers and traditional interferometers lies in the beam splitting and mixing elements. Parametric amplifiers are active quantum devices that generate quantum fields, whereas beam splitters are passive devices and rely on injection of quantum states to achieve quantum advantages. So, compared to the traditional interferometers with quantum state injections, SU(1,1) interferometers exhibit some distinct features that make them more desirable in practical applications. The first one is that the involvement of nonlinear optical processes for wave mixing allows the coherent superpositions of waves of different types such as atomic spin waves, light waves, and acoustic waves. This type of mixing is impossible for linear beam splitters. The second is that the employment of parametric amplifiers leads to amplified noise levels at outputs that are much larger than the vacuum noise level. This means the outputs are immune to losses, which are detrimental to quantum information because of the vacuum noise coupled in through the loss channels. The third is that the quantum entanglement generated by parametric amplifiers leads to correlated quantum noise, which can be canceled at destructive interference. This gives rise to higher signal amplification than noise amplification and thus improved the signal-to-noise ratio (SNR) or enhanced sensitivity.
Interference effects involving nonlinear optical processes were demonstrated as soon as the nonlinear optical effects such as second harmonic generation were discovered.27 Because of the involvement of nonlinear optical processes, these nonlinear interference effects have some interesting applications in spectroscopy,28 optical imaging,29,30 and spatial and temporal shaping.31,32 They can be mostly understood with classical wave theory. At the quantum level of single photons when the gain of the parametric amplifiers is low, interferometers consisting of spontaneous parametric down-conversion were used to study two-photon or multi-photon interference,33,34 which cannot be explained by classical theory. These quantum interferometric effects are the basis for optical quantum information sciences.35 Moreover, recently a mind-boggling photon interference effect36 between two spontaneous parametric processes also found interesting applications in quantum imaging with undetected photons.37–41 All these phenomena were recently reviewed in a comprehensive article.42
On the other hand, when the gain of the parametric amplifiers in SU(1,1) interferometers is high, the quantum noise performance of the interferometers is totally different. Early research development of SU(1,1) interferometers in this regime was covered in the comprehensive review article.42 However, since the publication of the article, there has been significant progress in the field, especially in the realization of many variations of the SU(1,1) interferometer and its applications in quantum metrology, quantum information, and quantum state engineering that are not covered by the review article. Furthermore, there is some misunderstanding in the early research about the working principle of the interferometer for sensitivity improvement, which leads to non-optimized performance. The roles of each nonlinear element in the interferometer were also better understood now, which reveals the underlying physics of the interferometer.
In this paper, we will explain the basic working principle of SU(1,1) interferometers with the goal of practical implementation and applications. We will concentrate on the quantum noise performance of SU(1,1) interferometers in the high gain regime with an emphasis on improving the phase measurement sensitivity. We will have an in-depth discussion on the special features of the interferometer in this case, especially on the role played by quantum entanglement. Based on this discussion, we will find the optimum operation conditions for the best performance in the form of phase measurement sensitivity and compare it to the optimum classical measurement sensitivity. We will reveal the difference and similarity between SU(1,1) interferometers and squeezed state-based traditional interferometers. These are covered in Secs. II and III. For the experimental implementation of SU(1,1) interferometers, we will review in Secs. IV and V recent realizations of different forms of the interferometer including those with different types of waves. We will discuss in Sec. VI its applications in multi-parameter measurement, quantum information splitting, quantum entanglement measurement, and mode engineering of quantum states. We conclude in Sec. VII with prospects for future development.
II. PERFORMANCE OF TRADITIONAL INTERFEROMETRY
A traditional Mach–Zehnder interferometer with vacuum (|v⟩) or squeezed (|r⟩) states at the unused port (dashed line). |αps, r⟩ is a coherent squeezed state with for phase sensing.
A traditional Mach–Zehnder interferometer with vacuum (|v⟩) or squeezed (|r⟩) states at the unused port (dashed line). |αps, r⟩ is a coherent squeezed state with for phase sensing.
Note that the optimum condition T1 ≈ 1 leads to extremely unbalanced photon numbers in the two arms of the interferometer. This is in contrast to the popular balanced implementation of the interferometer.2,11 This gives rise to the controversy of two classical limits of phase measurement for the comparison with quantum measurement.43 However, the unbalanced scheme is consistent with the homodyne measurement technique where the local oscillator (LO) has much stronger intensity than the signal field. Here, in the unbalanced scheme, the phase-encoded field (â2) can be regarded as the signal field to be measured, whereas the other arm (â1) with a much larger photon number is treated as the LO. The condition of T2 = R2 = 1/2 corresponds to balanced homodyne measurement.44 Thus, the balanced homodyne measurement technique achieves the optimum phase measurement sensitivity in classical interferometry.
Perhaps, a better way to understand why we need to have an unbalanced interferometer for optimum sensitivity is through the intrinsic phase uncertainty Δ2φ in any optical field.45 The interference method measures the phase difference φ = φ1 − φ2 so that the measurement uncertainty is Δ2φ = Δ2φ1 + Δ2φ2 if the phase fluctuations in the two arms are independent (indeed, the quantum fluctuations are independent for coherent states). However, it was shown45 that the intrinsic phase uncertainty Δ2φi(i = 1, 2) is inversely proportional to Ii. Making I1 ≫ I2 gives Δ2φ1 ≪ Δ2φ2 so that Δ2φ ≈ Δ2φ2 = Δ2φps ∼ 1/Ips (the subscript ps denotes the phase sensing field). However, for a balanced interferometer, I1 = I2 or Δ2φ1 = Δ2φ2, so we have Δ2φ = 2Δ2φps. Hence, the unbalanced interferometer has half the measurement uncertainty as the balanced one11 and thus better sensitivity with twice the SNR.43
Note that, here, we only use one arm for sensing and the optimum condition is T1 ≈ 1 ≫ R1. If two arms are used for sensing such as the situations of Sagnac interferometers for rotation sensing and Laser Interferometer Gravitational Wave Observatory (LIGO) for gravitational wave sensing, the optimum condition will be T1 = R1 = 1/2 to give balanced interferometers.
In the expressions above, we assumed R1|α|2 ≫ g2 = sinh2 r so that the coherent state provides most of the photons for phase sensing. At a large r-value, the squeezed state contributes a sizable photon number for Ips and optimization between r and α will lead to the so-called Heisenberg limit of phase measurement.47,48
In practice, interferometers are usually operated at the dark fringe mode. This is because high sensitivity requires high Ips [see Eq. (7)], which can saturate the detectors. This requires φ = π, T1 = T2 ≫ R1 = R2. To avoid electronic noise, homodyne measurement is performed at the dark port (). In this case, the output noise is simply the vacuum noise or the squeezed noise from the unused input port ( in Fig. 2), so it can be easily shown1 that the SNR in this case is the same as the optimized classical SNR given by Eq. (7) or the squeezed state case given by Eq. (9).
III. SU(1,1) INTERFEROMETERS
A new type of interferometer, known as the so-called “SU(1,1) interferometer,”7,10–13 is formed when we replace the beam splitters in a Mach–Zehnder interferometer (MZI) with parametric amplifiers (Fig. 3), which can split and mix two input fields coherently for interference. It is well known that parametric amplifiers are active devices and produce quantum states by themselves,49,50 so the fields inside the interferometers possess some unique quantum behaviors even without the input of quantum fields. This new type of interferometer is of quantum nature by itself and will exhibit some advantages over traditional interferometers.
SU(1,1) interferometer, where beam splitters of traditional interferometers are replaced by parametric amplifiers (PA1, PA2) of gain G1, G2, respectively. is the photon number of the field sensing the phase change δ.
SU(1,1) interferometer, where beam splitters of traditional interferometers are replaced by parametric amplifiers (PA1, PA2) of gain G1, G2, respectively. is the photon number of the field sensing the phase change δ.
A. Parametric amplifiers as beam splitters
B. Interference fringe patterns
Comparing Eq. (13) to Eq. (1), we find three unique features that differentiate SU(1,1) interferometers [SU(1,1)] from Mach–Zehnder interferometers (MZI):
The two outputs of SU(1,1) are in phase in contrast to 180° out of phase for MZI in Eq. (1).
The interference fringes depend on the phase sum of φ1, φ2 instead of the phase difference in MZI.
The outputs are amplified when the gain parameters G2, g2 are large.
C. Quantum noise performance of SU(1,1) interferometers
Although the signal due to the phase change is increased in SU(1,1) as compared to MZI, one may argue that this is not surprising at all because of the amplification of the second PA in SU(1,1). We can achieve the same effect if we place an amplifier at the outputs of the MZI. However, as we will see, there is a significant difference in the noise performance. An amplifier at the outputs of the MZI will amplify not only the signal but also the noise. So, the use of an amplifier at best keeps the signal-to-noise ratio. As a matter of fact, due to added noise from its internal degrees of freedom, such an amplifier often degrades the signal-to-noise ratio, leading to reduced measurement sensitivity.53–55 The SU(1,1), on the contrary, will not amplify the noise as much as the signal, leading to an enhancement of the signal-to-noise ratio. The key is in the destructive interference of the quantum noise, and it can be understood from the following three perspectives.
1. Quantum noise reduction by destructive quantum interference
Note that Eq. (16) is independent of the quadrature angle θ, which means that the noise is minimum for all quadrature-phase amplitudes . This is quite different from squeezed state interferometry1–3 where only the squeezing quadrature has noise reduction. This indicates that the underlying physics for noise reduction here is quantum destructive interference, which reduces noise for the whole field including all quadrature-phase amplitudes, in contrast to the squeezed state interferometry where noise depends on the angle of quadrature-phase amplitudes.
2. Quantum beam splitter as a disentanglement tool
To understand how quantum interference occurs at PA2, we just need to recall Eq. (12), which shows the superposition of the quadrature-phase amplitudes of the incoming fields. Note that the relations are in quantum mechanical operator form, which means that quantum fluctuations or noise can be subtracted or added depending on the phase, giving rise to quantum interference. This shows that a parametric amplifier can act as a quantum beam splitter to split and mix waves. In this sense, the roles of a PA and a BS are the same in the mixing of waves: incoming waves are all superposed coherently. It is known that the two outputs of PA1 are entangled in the continuous variables of phases and amplitudes49,50 and two entangled fields can be transformed by a 50:50 beam splitter into two independent squeezed states with noise reduced at orthogonal quadratures.56–58 In this case, the BS acts as a disentangler that transforms two entangled fields into two unentangled fields. Since a PA and a BS are the same in wave mixing, the role of PA2 in the SU(1,1) interferometer is then a disentangler. This happens when the gains of PA1 and PA2 are equal, producing two unentangled fields at the outputs with noise at the vacuum level, as shown in Eq. (16).
On the other hand, the difference between a parametric amplifier (PA) and a linear beam splitter (BS) lies in the fact that a parametric amplifier (PA2) has amplified outputs. This feature can lead to the loss-tolerant property of SU(1,1) interferometers that we will discuss later in Sec. III E. It also leads to the following understanding.
3. Quantum noiseless amplification due to noise cancellation
D. Signal-to-noise ratio and the optimum phase measurement sensitivity in SU(1,1) interferometers
Note that the optimum SNR is obtained not with equal gains of the two PAs but under the condition of g2 > g1, g2 ≫ 1.62 The former was the operational condition commonly used in earlier discussions7,8,10,11 and experimental realizations of SU(1,1)12,13 and corresponds to the minimum noise level at the outputs, as shown in Eq. (16). However, it leads to an SNR of , which is a factor of 2 smaller than the optimum value given in Eq. (23).61
Comparing Eq. (23) to the optimum classical SNR in Eq. (7), we obtain an SNR enhancement factor of . This is a factor of 2 smaller than that of the squeezed state interferometry given in Eq. (9). The reason for this is related to the optimum scheme of SU(1,1) for phase measurement and will be discussed later in Sec. IV C.
Figure 4 shows a typical result of phase measurement by both an SU(1,1) interferometer (red, SU11) and a Mach–Zehnder interferometer (black, MZ) under the condition of the same phase sensing intensity.63 The peaks are the phase modulation signal, and the flat floor is the noise level of measurement. As can be seen, both the signal and noise are amplified for SU(1,1) as compared to MZI, but the signal gain is more than noise gain. We can extract SNRs from Fig. 4. Since it is in log-scale, the SNR of phase measurement is simply the difference of the peak value and the floor value. It is found that SNRSU(1,1) = 6.9 dB and SNRMZI = 3.9 dB, leading to an improvement of 3.0 dB in SNR by SU(1,1) over MZI.
Phase modulation signals and noise levels for an SU(1,1) interferometer (red) and a Mach Zehnder interferometer (black). Adapted with permission from Du et al., Opt Lett. 43, 1051 (2018). Copyright 2018 Optical Society of America.
Phase modulation signals and noise levels for an SU(1,1) interferometer (red) and a Mach Zehnder interferometer (black). Adapted with permission from Du et al., Opt Lett. 43, 1051 (2018). Copyright 2018 Optical Society of America.
Since both outputs of PA2 contain the information about the phase change, it is suggested15,43 to measure the joint quantity to combine the information. It is straightforward to show61 that in this case, the SNR is independent of g2 and has the optimum value given in Eq. (23), , but with no further improvement. The extra output nonetheless can be used for quantum information tapping (see Sec. VI C and Ref. 17).
It should be noted that the SNR enhancement of SU(1,1) interferometers over the classical SNR is due to the employment of parametric amplifiers, which require strong pumping for high gain and thus consume more energy or resources than traditional interferometers.
E. Effect of losses
Dependence of the measured quantum noise level as a function for the detection losses for various gain of the parametric amplifier (PSA gain). The value of 2 corresponds to the vacuum noise level. Reproduced with permission from Li et al., Opt. Express 27, 30552 (2019). Copyright 2019 Optical Society of America.
Dependence of the measured quantum noise level as a function for the detection losses for various gain of the parametric amplifier (PSA gain). The value of 2 corresponds to the vacuum noise level. Reproduced with permission from Li et al., Opt. Express 27, 30552 (2019). Copyright 2019 Optical Society of America.
In fact, the amplified quantum noise from PA2 can not only overcome the vacuum noise introduced through losses, but it can also fight against excess classical noise. This strategy was used in microwave detection to tackle the enormous thermal noise background in a microwave circuit65 (see Sec. V A).
SU(1,1)’s immunity to losses is only for the output fields of the SU(1,1). For losses inside the interferometer, however, it was shown11,66 that the effect is exactly the same as that on the squeezed state. So, SU(1,1) is not immune to its internal losses. This suggests that all the quantum advantage is from the quantum entanglement created in the first PA (PA1), whereas the second PA is simply a device for superposition to disentangle the two fields in the two arms of the interferometer.
Indeed, as variations of SU(1,1), we can replace the second PA with any linear device that can mix the two fields and achieve the same performance as SU(1,1), as we will see in the following.
IV. VARIATIONS OF SU(1,1) INTERFEROMETERS
A. The Scheme of a parametric amplifier and a beam splitter (PA + BS)
It has been known almost since the discovery of squeezed states and EPR-entangled states that in the case of degenerate frequency, they can be converted from each other by a 50:50 beam splitter.56,67 Since an EPR-type entangled state can be generated with a parametric amplifier,50 we can use a beam splitter to convert it to squeezed states and measure the phase change with reduced quantum noise, similar to the squeezed state interferometry. However, the statements above are for states with no coherent components and the photon number of squeezed states with no coherent component is too low to have any practical use.
The scheme of the parametric amplifier and beam splitter for a variation of the SU(1,1) interferometer. Adapted with permission from J. Kong, Z. Y. Ou, and W. Zhang, Phys. Rev. A 87, 023825 (2013). Copyright 2013 American Physical Society.
The scheme of the parametric amplifier and beam splitter for a variation of the SU(1,1) interferometer. Adapted with permission from J. Kong, Z. Y. Ou, and W. Zhang, Phys. Rev. A 87, 023825 (2013). Copyright 2013 American Physical Society.
If we use a 50:50 beam splitter, as in Ref. 56, it is straightforward to find that the output noise will be , while the signal is 2Ipsδ2, and the SNR is exactly the same as that in Eq. (23). So, this variation of SU(1,1) gives the same SNR improvement factor as the SU(1,1) over the traditional interferometer. It is interesting to note if we switch the positions of PA and BS, that is, using BS for beam splitting and PA for wave superposition, the result will not be that given in Eq. (29) but is the same as that in Eq. (7) for classical interferometers.58 This further demonstrates that the quantum advantage originates from the quantum entanglement in the phase probing beam produced by the first parametric amplifier. Note further that since we use a BS to superpose the signal and idler fields, they must be frequency degenerate and the scheme is sensitive to losses just like squeezed state interferometry.
B. Truncated SU(1,1) interferometer
Although waves need to be superimposed in order to show the interference effect, the method of superposition can vary. We have already seen the methods using a parametric amplifier and using a beam splitter. In these cases, the waves are physically superimposed and interference occurs at the optical fields of the outputs of the wave-combining devices. In particular, for the PA + BS scheme in Fig. 6, it requires the two fields from PA1 have the same frequency because of the use of the beam splitter for wave superposition. On the other hand, since homodyne detection makes quantum measurement of the quadrature-phase amplitude of the field, the photo-current from homodyne detection can be thought of as the quantum copy of the amplitude of the field. So, the mixing of the photo-currents after homodyne detections is equivalent to the superposition of the detected fields and we can replace the beam splitter with a post-detection current mixer to achieve field superposition. This is the idea behind the so-called “truncated” SU(1,1) interferometer proposed and reported by Anderson et al.,15,43 as shown in Fig. 7 where only the first parametric amplifier remains as compared to SU(1,1) interferometers in Figs. 1(b) and 6. The mixer for photo-currents from the homodyne detectors (HD) plays the same role as the second parametric amplifier in Fig. 1(b) and the beam splitter in Fig. 6 to superimpose the two fields in the interferometer for interference. The current after mixing shows the phase signal δϕ as well as the quantum noise cancellation effect due to entanglement in a typical SU(1,1) interferometer. It was shown43,61 that the SNR for phase measurement is the same as that in Eq. (23) in the ideal lossless condition. The truncated version of SU(1,1) was recently used in atomic force microscopy with quantum enhancement.68
The scheme of the truncated SU(1,1) interferometer. Reproduced with permission from Gupta et al., Opt. Express 26, 391 (2018). Copyright 2018 Optical Society of America.
The scheme of the truncated SU(1,1) interferometer. Reproduced with permission from Gupta et al., Opt. Express 26, 391 (2018). Copyright 2018 Optical Society of America.
Because direct detection is used in the truncated scheme and the PA + BS scheme of SU(1,1) interferometers, losses will have a significant effect on the quantum enhancement factor in a similar way to the squeezed state interferometry.
C. Dual-beam SU(1,1) interferometers
The dual-beam scheme of the SU(1,1) interferometer for phase measurement. Reproduced with permission from Liu et al., Opt. Express 27, 11292 (2019). Copyright 2019 Optical Society of America.
The dual-beam scheme of the SU(1,1) interferometer for phase measurement. Reproduced with permission from Liu et al., Opt. Express 27, 11292 (2019). Copyright 2019 Optical Society of America.
From the result above, we find that SU(1,1) at best matches the sensitivity of squeezed state interferometry. This seems to contradict the fact that SU(1,1) can reach the Heisenberg limit of phase measurement.7 However, the result in Eq. (33) is obtained under the condition of strong coherent state injection to boost overall phase sensing photon number Ips. With no coherent state injection, it was shown11 that the Heisenberg limit is recovered. It was further shown58 that when the gain parameter g1 of PA1 is comparable to the injected coherent state photon number, the Heisenberg limit can also be reached, similar to squeezed state interferometry.47,48
It was shown61 that when dual-beam phase sensing is implemented in the truncated scheme and the PA + BS scheme, the factor of 2 is also recovered, leading to the same SNR as the squeezed state interferometry. However, because of the second PA, the dual-beam SU(1,1) scheme here is tolerant to losses outside of the interferometer, similar to the original SU(1,1) interferometer in Fig. 3. Furthermore, different from the PA + BS scheme, the employment of separate homodyne detectors in the truncated scheme and the second PA in the dual-beam SU(1,1) scheme does not require the same frequency for the two fields from the first PA in both schemes. The experimental implementation of the dual-beam SU(1,1) interferometer was realized by Liu et al.,69 and about 3 dB improvement over the single-beam scheme was demonstrated.
D. Multi-stage SU(1,1) interferometers
Similar to multi-path interferometers such as Fabry–Perot interferometers and multi-slit interference in optics, we can also add more PAs to form multi-stage SU(1,1) interferometers. In order to have all the PAs playing the same role in the multi-path interference, we usually work at a low gain regime of the PAs so that spontaneous emission dominates and two-photon states are generated. This variation of the SU(1,1) interferometer finds its application in the modification of mode structures (temporal and spatial) in the output field for mode engineering of the output quantum states. The detail of this application can be found later in Sec. VI E. In the following, we will present the general principle for this scheme.
Consider the multi-stage interferometer shown in Fig. 9 where the kth PA is described by the small amplitude gain parameter 0 < gk ≪ 1 so that the power gain . In between the PAs sandwiched are phase shifters . For simplicity, we assume the phase shifters have the same phase of the amount θ for the two fields of the PAs together. In the low gain limit, in order to better describe the performance of the system and reveal the underlying physical principle, we will work in the Schödinger picture with quantum states. Let us start with the quantum state of one PA.
The high gain case is not easy to treat because of the general non-commuting nature of the Hamiltonian for different PAs.71 Nevertheless, it still gives rise to the modification of the mode structure at the output similar to the low gain case.
V. SU(1,1) INTERFEROMETERS OF DIFFERENT WAVES
A. SU(1,1) interferometer with microwaves
Parametric amplifiers were first realized in radio frequency and microwaves.72 However, thermal and electronic noise is often so large that it overwhelms the quantum noise in detection processes. So, it is hard to study the quantum behavior of the amplifiers in radio frequency and microwave regimes. This was changed recently when near quantum limit low noise parametric amplifiers were invented.73 Although thermal and electronic noise is still very high in detection processes, Flurin et al.65 utilized the low noise parametric amplifier at high gain as a beam splitter to reveal the EPR-type quantum correlation between two entangled microwave fields generated by another low noise parametric amplifier. Similar to the role played for loss tolerance by the second parametric amplifier in an SU(1,1) interferometer, Flurin et al.65 used the low noise parametric amplifier to amplify the quantum noise to a level that is much larger than the thermal and electronic background noise in the detection process. In this way, they achieved the measurement of the correlated quantum noise from EPR-entangled microwave fields even in the presence of the enormous thermal and electronic background noise.
Working on the goal to demonstrate the EPR-type entanglement between microwave fields, Flurin et al.65 inadvertently realized an SU(1,1) interferometer in the microwave regime. In their arrangement shown in Fig. 10, the first amplifier (PA1) is the EPR-entangled source (entangler), while the second one (PA2) is the one that measures the entanglement (analyzer). This geometry is exactly in the form of Fig. 3 and is an SU(1,1) interferometer but without seeding of a coherent state. Indeed, the measurement result shows an interference pattern that depends on the phase difference Δφ of the pumps.65 Note that during the experiment described in Ref. 65, the gain of the analyzer (PA2) is much larger than 1 and is always larger than that of the entangler (PA1). This is exactly the setting for achieving the optimum performance of the SU(1,1) interferometer presented in Eq. (23). The large gain in the analyzer (PA2) also satisfies what is required for PA2 to act as an entanglement measurement device (see more later in Sec. VI D and Ref. 64).
SU(1,1) interferometer for microwaves. Adapted with permission from Flurin et al., Phys. Rev. Lett. 109, 183901 (2012). Copyright 2012 American Physical Society.
SU(1,1) interferometer for microwaves. Adapted with permission from Flurin et al., Phys. Rev. Lett. 109, 183901 (2012). Copyright 2012 American Physical Society.
B. Atom-light hybrid interferometers
One of the key differences of an SU(1,1) interferometer from a traditional interferometer is the way of wave splitting and superposition for interference: it is through nonlinear mixing of waves. This method can therefore couple different types of waves for interference, which is basically impossible in a traditional interferometer. This leads to hybrid interferometers where the two interfering waves are different types of waves. One such interferometer is the atom-light hybrid interferometer, first realized by Chen et al. in 2015.51
Hybrid atom-light interferometers. (a) Schematic diagram of the interferometer; PBS: polarization beam splitter, BS: beam splitter, M: mirror, D: detector, B: magnetic field for atomic phase change. (b) Time sequence of light pulses. (c) MZ interferometer-equivalent interference paths for atomic spin wave Sa and optical wave aS, RA1, RA2: Raman amplifiers. Inset: atomic levels and optical waves.
Hybrid atom-light interferometers. (a) Schematic diagram of the interferometer; PBS: polarization beam splitter, BS: beam splitter, M: mirror, D: detector, B: magnetic field for atomic phase change. (b) Time sequence of light pulses. (c) MZ interferometer-equivalent interference paths for atomic spin wave Sa and optical wave aS, RA1, RA2: Raman amplifiers. Inset: atomic levels and optical waves.
In most applications of Raman amplifiers, the atomic states are treated as inaccessible internal states of the amplifier, which are often in the vacuum state (unexcited state) and are not taken into consideration. They are responsible for the spontaneous emission noise of the amplifier. For the action of the SU(1,1) interferometer, as we see from Sec. III, it requires the atomic spin wave to participate as one of the interfering fields. Therefore, the atomic spin wave is a part of the waves participating in the interference together with the optical Stokes field. So, the interference fringe will depend on both the atomic phase and the optical phase, thus forming an atom-light hybrid SU(1,1) interferometer. The schematic diagram is shown in Fig. 11(a). The input Stokes field aS1, after interacting with atoms pumped by the first writing field W1 [see Fig. 11(b) for the time sequence], is amplified as aS2. In the meantime, an atomic spin wave Sa is also generated in the atomic ensemble. This is the wave splitting process [RA1 in Fig. 11(c)]. Since the atomic spin wave stays in the atomic ensemble, to combine it with the amplified Stokes, we send back with a mirror (M) the delayed Stokes field together with the second write field W2 [RA2 in Fig. 11(c); see Fig. 11(b) for the time sequence]. This design is somewhat similar to a Michelson interferometer where one BS is used for dual purpose.14 The output aS3 is detected by D to reveal the interference fringe as the optical or atomic phase is scanned. The atomic phase can be changed by the external magnetic field via the Zeeman effect, as demonstrated by Chen et al.51
The atomic phase can also be altered by shining an off-resonant light beam on the atoms via the AC Stark shift.76 Thus, an interesting application of the atom-light interferometer is to measure the photon number of the off-resonant light field in the sense of quantum non-demolition (QND) measurement.77 This approach is similar to the QND measurement scheme for microwave photons.78
C. Atomic SU(1,1) interferometer
Atomic SU(1,1) interferometer. (a) Interferometric scheme with the wave splitting and recombination processes equivalent to parametric amplifiers (PAs). (b) The output atomic number distributions as the phase of the atomic waves changes. Reproduced with permission from Linnemann et al. Phys. Rev. Lett. 117, 013001 (2016). Copyright 2016 American Physical Society.
Atomic SU(1,1) interferometer. (a) Interferometric scheme with the wave splitting and recombination processes equivalent to parametric amplifiers (PAs). (b) The output atomic number distributions as the phase of the atomic waves changes. Reproduced with permission from Linnemann et al. Phys. Rev. Lett. 117, 013001 (2016). Copyright 2016 American Physical Society.
The atom-light hybrid interferometer discussed in Sec. V B and the atomic SU(1,1) interferometers discussed here all involve atomic internal states. An atomic interferometer usually refers to interferometers involving the de Broglie matter waves of atoms via their external motional states.82 An SU(1,1) of this type requires matter wave amplifiers,83,84 which can be realized by four-wave mixing of matter waves.85
For the hybrid atom-light interferometer involving the external translational degrees of freedom of atoms, we need to go back to Raman amplification but deal with ultra-cold atoms in a BEC86–88 where super-radiance of light is correlated with the atomic motional states in a similar way as in Eq. (38).
D. Phonon SU(1,1) interferometer
For an all-phonon SU(1,1) interferometer, strong nonlinear interaction between mechanical oscillators is required. This was realized by Patil et al.,91 who demonstrated parametric amplification of phonons and thermo-mechanical noise squeezing. Equipped with phonon parametric amplifiers, Cheung et al.92 realized a PA + BS version of the all-phonon SU(1,1) interferometer (Sec. IV A) where the second parametric amplifier is replaced by a beam splitter.
VI. APPLICATIONS OF SU(1,1) INTERFEROMETERS
The primary application of SU(1,1) interferometers is in phase measurement. It was shown in Sec. III D that the phase measurement sensitivity can beat the standard quantum limit. On the other hand, as we have found in Sec. III C 1, the noise reduction in SU(1,1) is due to quantum destructive interference, which reduces all noise of the whole output fields of the interferometer. So, the sensitivity enhancement effect is not limited to phase measurement and can also be applied to the measurement of other quadrature-phase amplitudes such as amplitude measurement, as we will show next.
A. Multi-parameter measurement
As is well known, phase and amplitude are conjugate variables so that the Heisenberg uncertainty principle prevents their simultaneous measurement with precision beyond what the uncertainty principle allows. However, this limitation is on one object and the entanglement between two objects can break this limitation, which is what leads to the famous EPR paradox in an apparent violation of the Heisenberg uncertainty relation.49,50,93 However, Braunstein and Kimble57 made use of this seemingly contradicting behavior of the entangled source to achieve simultaneous measurement of phase and amplitude with measurement precision, beating the limit set by the Heisenberg uncertainty relation. The experimental demonstration of this phenomenon was first performed by Li et al.94 following a proposal by Zhang and Peng,95 which is a variation of the quantum dense coding scheme of Braunstein and Kimble.57 More recently, Steinlechner et al.96 applied the same technique to a prototype interferometer for gravitational wave detection with simultaneous measurement of two non-orthogonal quantities.
Simultaneous phase (δ) and amplitude (ε) measurement by using an SU(1,1) interferometer. HD: homodyne detection and BS: beam splitter. Reproduced with permission from Liu et al. Opt. Express 26, 27705 (2018). Copyright 2018 Optical Society of America.
Simultaneous phase (δ) and amplitude (ε) measurement by using an SU(1,1) interferometer. HD: homodyne detection and BS: beam splitter. Reproduced with permission from Liu et al. Opt. Express 26, 27705 (2018). Copyright 2018 Optical Society of America.
The above application of the SU(1,1) interferometer to the simultaneous measurement of phase and amplitude was experimentally demonstrated by Liu et al.19 Furthermore, the measurement scheme is extended to simultaneous measurement of multiple non-commuting observables, which are not necessarily orthogonal [HD1 for , HD2 for , HD3 for in Fig. 13 with arbitrary ϕ1, ϕ2, ϕ3]. Since outputs are amplified, we can further split the signal output without introducing vacuum noise for the simultaneous measurement of another modulation non-orthogonal to phase and amplitude by HD3 of .
The advantages of the SU(1,1) interferometer over the quantum dense coding scheme57 are as follows: (1) more than two non-commuting quantities can be simultaneously measured and (2) it is tolerant to propagation and detection losses.
B. Quantum resource sharing
C. Quantum information tapping
It is well known99 that when quantum information is split with a beam splitter, vacuum noise comes in from the unused port, leading to degradation of SNRs of the split signals as compared to the input. Shapiro suggested using squeezed states to combat the vacuum noise and preserve the SNRs of the split signals.99 This is the so-called quantum information tapping. Such a scheme was implemented by Bruckmeier et al.100
D. Measurement of entanglement in continuous variables
Verification of quantum entanglement between two light sources is a basic experimental technique in quantum information. For continuous variables, it is usually done via the homodyne detection technique by directly measuring the quadrature-phase amplitude correlations of the two fields: and ⟨Δ2Ŷ+⟩ with and Ŷ+ ≡ Ŷ1 + Ŷ2.49,50,103,104 Quantum entanglement satisfies the inseparability criterion: .105 However, this traditional homodyne method is prone to loss, which severely limits the application of entanglement. On the other hand, as we have shown in Sec. III A, parametric amplifiers (PAs) can act as non-conventional beam splitters for mixing of two fields, which is exactly performed when quantities and Ŷ+ ≡ Ŷ1 + Ŷ2 are measured, forming an SU(1,1)-type interferometer. We analyze this scheme next.
Entanglement measurement with the help of a parametric amplifier (PA). HD: homodyne detection. LD: detection loss. Reproduced with permission from Li et al., Phys. Rev. A 101, 053801 (2020). Copyright 2020 American Physical Society.
Entanglement measurement with the help of a parametric amplifier (PA). HD: homodyne detection. LD: detection loss. Reproduced with permission from Li et al., Phys. Rev. A 101, 053801 (2020). Copyright 2020 American Physical Society.
The discussion above is for the single-mode case. For the multi-mode case, parametric amplifiers have the ability to select the dominating mode.106 This is because different modes have different parametric gains. In the high gain limit, the mode with the largest gain will dominate. Thus, application of parametric amplifiers to entanglement measurement can also filter out unwanted higher order modes and concentrate on the dominating mode. By using the mode engineering technique on parametric amplifiers discussed in Sec. VI E, we can select the mode of our interest.
The scheme discussed above for entanglement measurement was implemented experimentally by Li et al.64 with fiber optical parametric amplifiers, demonstrating the loss-tolerant and mode selecting properties for the high gain case.
E. Mode engineering of quantum states with SU(1,1) interferometers
Another interesting application of SU(1,1) interferometers is the modification of the mode structure of the quantum state in the output fields to achieve quantum state engineering. The mode structure of quantum states has recently attracted a lot of attention because it increases the degrees of freedom for quantum fields and is especially appealing to quantum information science because of its ability to achieve multi-dimensional quantum entanglement (see a comprehensive review by Fabre and Treps107). Modes of photons play essential roles in quantum interference because they define the identity of photons and often lead to distinguishability.108 It is crucial to have mode match between interfering fields in order to achieve high visibility. Our discussion so far on SU(1,1) interferometers has assumed perfect mode match. Multi-mode behavior of SU(1,1) is also quite different from linear interferometers. In fact, a recent work demonstrated the mode cleaning ability of SU(1,1).64,106 In the following, we will discuss the ability of SU(1,1) for tailoring the mode structure of quantum fields to our need.
The modification of the mode structure is achieved by engineering the phase change in between the two PAs. This idea was put into action31,32 soon after the first experimental realization of the SU(1,1) interferometers.12,13 It can be used to modify both spatial31,109,110 and temporal/spectral32,111–115 profiles of the output fields. More recently, a multi-stage SU(1,1) (Sec. IV D) was implemented for precise and versatile engineering of the spectral mode function of the output quantum states.116 As an example, we present here the interferometric scheme to achieve flexible and precise spectral mode engineering for the two-photon state produced from spontaneous parametric emission (SPE) processes.
If the frequencies of the signal and idler photons are close to each other, that is, |ωs0 − ωi0| ≪ ωs0, ωi0, then the sinc-function in F(Ωs, Ωi) has a broad bandwidth much wider than the pump bandwidth σp. In this case, F(Ωs, Ωi) is mainly determined by the exponential function and forms a strip along −45°, as shown in Fig. 15(a). The strip orientation of −45° reflects the frequency anti-correlation between the signal and idler photons due to energy conservation of photons. This shape of JSF gives rise to a two-photon state with multiple temporal modes and is not desirable for quantum interference in quantum information applications. Single-mode two-photon states are preferable, corresponding to a factorable JSF with a shape such as a round circle.
Contour plot of the joint spectral function F(Ωs, Ωi) (JSF) of a two-photon state generated from four-wave mixing processes in optical fibers, but the variables are in wavelengths, as in the original paper113 (Ωl ≡ ωl − ωl0, λl = 2πc/ωl, l = s, i). (a) A single parametric process. (b) An SU(1,1) interferometer with spectrally dependent phase for the modification of JSF. Marginal intensity distribution I(Ωs) is below the horizontal axes. Reproduced with permission from Su et al., Opt. Express 27, 20479 (2019). Copyright 2019 Optical Society of America.
Contour plot of the joint spectral function F(Ωs, Ωi) (JSF) of a two-photon state generated from four-wave mixing processes in optical fibers, but the variables are in wavelengths, as in the original paper113 (Ωl ≡ ωl − ωl0, λl = 2πc/ωl, l = s, i). (a) A single parametric process. (b) An SU(1,1) interferometer with spectrally dependent phase for the modification of JSF. Marginal intensity distribution I(Ωs) is below the horizontal axes. Reproduced with permission from Su et al., Opt. Express 27, 20479 (2019). Copyright 2019 Optical Society of America.
The JSF of the two-photon state can be modified by using an SU(1,1) interferometer with a spectrally dependent phase θ by using a linear dispersive medium sandwiched in between the two PAs, as shown in Fig. 9 with N = 2. Then, the interference term H(θ) = 2 cos θ in Eq. (37) will modify the single PA term g or the JSF F(Ωs, Ωi) in Eq. (54) for the broadband case. For the case of near degenerate frequencies of |ωs0 − ωi0| ≪ ωs0, ωi0, the first-order dispersion disappears and second-order dispersion leads to with β being proportional to the second-order dispersion coefficient and LDM as the length of the linear dispersive medium. Figure 15(b) shows the modified JSF together with the marginal intensity I(ωs) of the signal field, showing the interference fringe. The island structure of the modified JSF is a result of two-photon interference and forms a multi-dimensional two-photon state with entanglement between different islands.117 Filters can be used to select the roundest island for a nearly factorable JSF (yellow dashed lines). The shape of the islands can be adjusted depending on the pump bandwidth σp and the length LDM of the dispersive medium.
The cleanliness and thus better quality of the selected island depend on the visibility of interference. This can be improved with a multi-stage design, presented in Sec. IV D, where the interference term will make the islands well separated with increasing stage number N, as shown in Fig. 16. The improved visibilities in the interference pattern shown in the marginal intensity should give a cleaner JSF with better quality as N increases. However, the well-known mini-peaks of the H(θ) function between the main islands are troublesome. Further shaping of the H(θ) function can be done with a design of uneven gain gk or gain medium length Lk(gk ∝ Lk) distribution among N PAs. It was shown that a binomial distribution Lk = L1(N − 1)!/(k − 1)!(N − k)! (k = 1, 2, …, N) will eliminate the mini-peaks, leading to an improved JSF.118
Contour plot of the joint spectral function F(Ωs, Ωi) (JSF) for the output state from a multi-stage SU(1,1) interferometer. N = (a1) 3, (a2) 4, and (a3) 5. The variables are in wavelengths as in Fig. 15. Reproduced with permission from Su et al., Opt. Express 27, 20479 (2019). Copyright 2019 Optical Society of America.
Contour plot of the joint spectral function F(Ωs, Ωi) (JSF) for the output state from a multi-stage SU(1,1) interferometer. N = (a1) 3, (a2) 4, and (a3) 5. The variables are in wavelengths as in Fig. 15. Reproduced with permission from Su et al., Opt. Express 27, 20479 (2019). Copyright 2019 Optical Society of America.
With SU(1,1) interferometers, there are many degrees of freedom for adjustment and fine tuning in the modification of the JSF of the two-photon state to achieve what we want. Although the discussion is for the low gain case (g ≪ 1), it was shown experimentally that the interferometric technique works equally well in the high gain regime for the precise engineering of the mode structure of entangled fields in continuous variables.111,112,115,118 However, all the theoretical treatment112,118 in this case does not consider the non-commuting property of the Hamiltonian between different PAs.71
VII. SUMMARY AND FUTURE PROSPECTS
SU(1,1) interferometers are a new type of interferometers that employ nonlinear interactions such as parametric processes to split and mix beams for interference. They possess some unique properties, making them advantageous over the traditional beam splitter-based interferometers. These properties include higher sensitivity, detection loss tolerance, and mixing of different types of waves. A key feature of the interferometer is the quantum correlation between the two interfering arms of the interferometer, which is responsible for the enhancement of phase measurement sensitivity. The involvement of the parametric amplifier in the superposition of the interfering waves leads to the loss tolerance property that has some practical implications in quantum metrology. The nonlinear mixing of different types of waves for interference opens up doors for potentially much wider application of this new type of interferometer than the traditional interferometers. These advantages originate from the employment of parametric amplifiers in the interferometers. Parametric amplifiers are active elements requiring strong pumping and are thus very resource intensive. Despite these demonstrated advantages, we still have many challenges, both fundamental and technological, in the further development of the technique of SU(1,1) interferometers.
Among these advantageous properties, the ability to mix waves of different types in SU(1,1) interferometers will make them more promising than others for sensing applications in wide areas. It will be especially attractive to those waves that lack an efficient way of detection such as THz and far infrared waves. SU(1,1) interferometers allow sensing of phase changes in these waves but make detection at other waves for which detection efficiency is high, so long as there is a coupling between these waves for nonlinear mixing. In fact, this idea has already been applied to spectral sensing and imaging of an object with photons at one wavelength but detecting at another.28,37–41 This should also widen our capability to construct sensors for measuring a variety of physical quantities through these waves. For example, coupling an atomic de Broglie wave through translational degrees of freedom to light by super-radiance87,88,119 will allow us to sense gravitational field. An all-matter wave SU(1,1) interferometer can also be used to measure gravity and will require matter wave mixing85 for its realization. To make these applications possible, we need to look for nonlinear mixing between waves of our interest. Of course, these interactions may not be in the form of parametric interaction given in Eq. (10) and the interferometers constructed with them will not be SU(1,1)-type as we discussed in this paper. They will have totally different properties yet to be explored. An example is the engineered multi-particle interaction for phonons in trapped ion systems.120
The experimental realizations discussed in this paper are mostly proof-of-principle experiments, and they are operated under relatively small phase sensing photon numbers (Ips). For their wide applications in sensing, we still need to see how they can be adapted to practical situations and different environments. For example, for surpassing the performance of traditional interferometers in actual sensing applications, we need to increase the absolute sensitivity. This is achieved by increasing the phase sensing photon number Ips. However, this usually leads to saturation of the parametric amplifiers and other unwanted nonlinear effects such as self-phase modulation in optical fibers. Perhaps, the solution to this problem lies in the selection of operating points at relatively low overall gain of the interferometer with double injection, as suggested in Ref. 10 and realized in Ref. 94. A recent proposal suggests to tap some of the pump photons for sensing to increase Ips.25 Different applications require different variations of SU(1,1) interferometers. For example, how can SU(1,1) interferometers be adapted to measure rotation like Sagnac interferometers do? This is not obvious since the SU(1,1) interferometers depend on the phase sum instead of phase difference.
To take the quantum advantages for realization of quantum sensing, we need to have an effective way to control the internal losses of the interferometers. Although SU(1,1) interferometers are relatively immune to external losses such as detection inefficiency, what limits the enhancement of sensitivity is the internal losses experienced by the fields in between the two PAs or the losses suffered by the PAs.11,66 These losses will introduce uncorrelated vacuum noise that cannot be canceled by quantum destructive interference, leading to extra noise and reducing SNRs. This is not fundamental but poses practical challenges in device construction.
As we discussed at the end of Secs. IV D and VI E, the high gain case in multi-stage SU(1,1) has not been treated theoretically because of the issue of non-commuting Hamiltonian of different PAs. The high gain regime of the parametric amplifier is important because it can generate EPR-type quantum entanglement in continuous variables.49,50 It is the basis for complete quantum state teleportation and quantum metrology applications. Thus, this will be a challenge for future theoretical investigation of SU(1,1).
SU(1,1) interferometers have the potential to reach the ultimate Heisenberg limit (HL) of phase measurement sensitivity. However, as we have seen, internal losses are the main obstacle for improving sensitivity. How will losses affect the ability of SU(1,1) interferometers to reach the Heisenberg limit?
The approach of SU(1,1) interferometers is to change the structures of interferometers by replacing beam splitters with parametric amplifiers. This is in contrast to the approach of inputting different quantum states for sensing in traditional interferometers. It is known that parametric amplifiers are quantum devices producing quantum states by themselves, whereas beam splitters are classical devices that do not produce quantum states by themselves but rely on the injection of quantum states to achieve quantum sensing. The former approach can be thought of as the hardware change of devices, whereas the latter as the software programming of input states. The general condition for optimum quantum states was derived before.8 Is there an optimum interaction or hardware design in the construction of the non-traditional interferometers for sensing or other applications? Answer to this and other aforementioned questions will likely broaden our knowledge and applications of non-traditional interferometers.
DATA AVAILABILITY
Data sharing is not applicable to this article as no new data were created or analyzed in this study.
ACKNOWLEDGMENTS
The authors would like to thank the support from the National Natural Science Foundation of China (Grant Nos. 11527808 and 91736105), the National Key Research and Development Program of China (Grant No. 2016YFA0301403), and the US National Science Foundation (Grant No. 1806425).