One of the challenges of quantum technologies is realizing the quantum advantage, predicted for ideal systems, in real applications, which have to cope with decoherence and inefficiencies. In quantum metrology, sub-shot-noise quantum imaging (SSNQI) and sensing methods can provide genuine quantum enhancement in realistic situations. However, wide-field SSNQI schemes realized so far suffer a trade-off between the resolution and the sensitivity gain over a classical counterpart: small pixels or integrating area are necessary to achieve high imaging resolution, but larger pixels allow a better detection efficiency of quantum correlations, which means a larger quantum advantage. Here, we show how the SSNQI protocol can be optimized to significantly improve the resolution without giving up the quantum advantage in sensitivity. We show a linear resolution improvement (up to a factor 3) with respect to the simple protocol used in previous demonstrations.

Imaging delicate systems using a small number of incident photons with true and significant quantum enhanced sensitivity is extraordinarily important for applications, from biology and medicine to fundamental physics research. The first proof of principle of sub-shot-noise quantum imaging (SSNQI) of a 2D absorption/transmission mask was given in 2010,1 and in 2017, some of us reported the realization of the first wide-field sub-shot noise microscope.2 It is based on spatially multi-mode non-classical photon number correlations of twin-beam states, produced by spontaneous parametric downconversion (SPDC) and detected by a high quantum efficiency CCD camera.3–7 The sample (2D mask) is probed by one beam with a certain level of quantum fluctuations, so that the detected image is affected by a noise pattern. However, a second reference beam, locally correlated in the photon number with the first one, generates at the detector an identical noise pattern. In this way, one can simply remove the noise by subtraction. The microscope of Ref. 2 produces real-time images of several thousand pixels and 5μm of resolution even though the actual quantum enhancement in sensitivity compared to the best classical protocol is effective at larger spatial scales. In fact, in this technique, there is a clear trade-off between the resolution and the quantum enhancement, due to the fact that pixels or integrating areas smaller than the characteristic size of the spatial modes do not intercept all the correlated photons between pairs of conjugated modes. With the aim of improving the performance of this technique, in Ref. 8, we studied in deep detail the problem of absorption estimation by photon counting toward the ultimate quantum limit, taking into account experimental inefficiencies. In particular, we analytically showed the advantage of the optimized estimator proposed in Ref. 9, especially in the case of limited detection efficiency. This estimator does not involve modification of the setup, but only a slightly different use of the data and a pre-calibration of the system.

Here, we use this estimation protocol to shift the resolution-sensitivity trade-off of the SSNQI, improving the resolution of a factor 3 in the best case. It turns out that in this way, it is in principle possible to obtain SSNQI at the Rayleigh resolution limit.

The lower bound to the uncertainty in a loss estimation for classical probes, i.e., mixture of coherent states, is10 

(1)

where nP is the mean number of photons of the probe and 0α1 is the loss induced by the sample. Only for high losses, the uncertainty can be arbitrarily small, while in the case of a faint loss, one retrieves the expression Usnl=nP1/2, usually referred to as the “shot-noise-limit” (SNL).

In general, excluding adaptive strategies where the limit is still unknown,10 the ultimate quantum limit (UQL) of sensitivity for a single mode probe is UuqlαUcoh,11,12 which scales much more favorably than the classical bound for small losses. Several quantum states have been demonstrated to reach, in principle, this ultimate limit: single mode squeezed vacuum, with the detection strategy based on photon counting and Gaussian operations, for small losses and a small number of photons;11 Fock states |n, with photon counting, unconditionally for any α but if nP1;12 and two-mode squeezed vacuum (TMSV) state with photon counting,13 unconditionally for any loss and all energy regimes.14 TMSV is the photon number entangled state,

(2)

where the subscripts “R” and “P” represent two correlated modes, and the probability amplitude is cnnPn/(nP+1)n+1,withnP being the mean number of photons in each of the two modes.

On the experimental side, a seminal proposal on the absorption measurement with photon pairs produced by SPDC, i.e., using a faint TMSV state, was given already in 198615 and a sub-shot-noise measurement of modulated absorption using SPDC has been realized few years later.16 More recently, quantum enhanced absorption measurements have been performed by post-selected heralded single photon Fock states17 and also through an active feed-forward driven by an optical shutter.18 In those cases, on/off single photon detectors have been used. However, the higher genuine quantum enhancement has been achieved in experiments exploiting the low noise intensity measurement (photon counting), taking advantage of the high quantum efficiency and small electronic noise of modern CCD cameras.8,9 An enhancement of the order of 50% with respect to the classical bound has been achieved for the same number of detected photons and 32% if perfect detection efficiency is considered only for the classical scheme.8 With these detectors, which also provide flexible spatial resolution and exploiting the spatially multimode emission of traveling wave SPDC, it has been possible to devise,6 and realize1,2,19 wide field SSNQI schemes where a 2D amplitude mask is recovered by parallel multi-parameter absorption/transmission estimation.

Reference 8 reports a systematic study of the performance achieved by several possible estimation strategies based on the detected number of photons jointly measured in the probe, named NP in the presence of the sample, NP in the absence of it, and the reference NR. In summary, three estimators have been considered there:

  • Ratio, as used, for example, in Ref. 15,
    (3)
  • Subtraction, considered for SSNQI,1,2,6
    (4)
  • Optimized subtraction, considered in Refs. 16 and 9,
    (5)

The factor γ=NR/NP is introduced to account for unbalancing between the mean energy detected in the reference arm and in the probe arm without the sample. It can be evaluated in a pre-calibration of the apparatus, which should last long enough to provide an accurate determination of γ. In the third estimator, the factor kopt must be optimized as a function of the physical parameters of the system. In particular, it turns out that kopt is a function of the detection efficiencies of the channels and the local excess noise. Clearly, each of the three estimation strategies is based on the idea that the common photon number fluctuations of the probe and reference beam can be suppressed or at least mitigated by a direct comparison. However, in terms of the uncertainty, they behave differently. For the general expressions, obtained propagating the uncertainty on the photon numbers NP, NP, and NR, the reader should refer to Ref. 8. For simplicity, here we consider the same detection efficiency ηd in the two arms, i.e., γ = 1. Moreover, we consider a large number M1 of spatiotemporal realizations of TMSV states in Eq. (2) (here collectively named the twin-beam state), detected by each pixel in the measurement time, where nP=NP/(ηd·M). In the following, we will consider the limit of MNP1. On one side, this condition takes into account the typical experimental situation where the detectors have a limited bandwidth, and the source has a low brightness, nP1. On the other side, it allows us to consider the statistics of NP, in general, multi-thermal, approaching a Poissonian distribution, where each pixel can be considered statistically independent of others in the same arm. In this limit, the expressions of the uncertainty on α can be written as (see Ref. 8 for more details)

  • Uncertainty of the Ratio
    (6)
  • Uncertainty of the Subtraction
    (7)
  • Uncertainty of the Optimized subtraction
    (8)

In the above equations, the parameter η (0<η1) is related to the noise reduction factor NRF=Δ2(NPNR)/NP+NR20–22 by the relation NRF=1η. The NRF represents the level of correlation of the joint detected photon number distributions and can be estimated experimentally. For 0NRF<1, the correlations are non-classical. Here, η can be interpreted as the efficiency in detecting correlated photons, i.e., the probability that for a photon detected in a certain pixel in the probe arm, its twin photon is detected in the correlated pixel in the reference arm. Thus, it can be written as the product of the channel detection efficiency and a collection efficiency term, η=ηd·ηc. The collection efficiency ηc takes into account for the fact that in real systems, correlated modes cannot be always perfectly detected. In the ideal situation, assuming η=1, both the Ratio in Eq. (3) and the Optimized estimator in Eq. (5) reach the UQL, while the Subtraction estimator in Eq. (4) approaches the UQL only asymptotically for a small value of the loss α. However, another significant difference appears in the non-ideal detection case, because of the different dependence of Eqs. (6)–(8) from η. In particular, for the Ratio and the Subtraction estimators, the positive additive term exceeding the UQL is 2(1η), which is larger than the one for the Optimized case (1η2), for any value of η. This means that the Optimized estimator works always better than the others and that this advantage is larger for low efficiency η. For example, rewriting Eqs. (6)–(8) in terms of the classical bound Ucoh of Eq. (1), it is easy to see that the quantum advantage for the Ratio or the Subtraction estimators starts from η0.5. In contrast, the twin beam state together with the Optimized subtraction protocol performs always better than the classical bound. In the following, we will show how this feature of the Optimized estimator is particularly suited for the SSNQI improvement also in terms of resolution.

In wide-field imaging realizations with SPDC,1,2 the spatial pattern in the far field of the emission, where the transmitting mask is placed, is a continuous distribution of independent spatial modes with a certain coherence area given by the Fourier transform of the pump beam profile. This plane is then projected at the pixel's matrix of the detector chip, where probe and reference beams are detected in two different regions. Figure 1 describes the details of our experimental setup.

FIG. 1.

A multi-mode twin-beam state is produced through the SPDC, pumping a non-linear crystal (Type-II-Beta-Barium-Borate, BBO) with a CW laser-beam (100 mW at λpump=405 nm). The down-converted photons around the degeneracy wavelength, λd=810 nm, are spectrally selected using an interferential filter [IF, (800±20 nm)]. The resulting state can be approximated as a tensor product of independent TMSV states as |Ψ=q,λ|TMSV, where q and λ are the transverse momentum and the wavelength of one of the two photons produced, while momentum and wavelength of the other photon are fixed by energy and momentum conservation. The far field is obtained at the focal plane of a lens with fFF = 1 cm focal length, where the correlation in momentum is converted into correlation between symmetric positions. A coated glass-slide with a 2D absorbing mask, realized as a thin titanium deposition of absorption α1%, is placed in this plane. This is then imaged (magnification of 7.8) to the chip of a charge-coupled-device (CCD) camera with a nominal quantum efficiency of 95% at 810 nm and a pixel size of 13μm. We perform a 3 × 3 pixel binning, to set the resolution to 5 μm at the object plane, which matches the measured cross correlation length. The acquisition time of a single frame is 100 ms, the number of temporal modes per pixel per frame is 1011, and the number of photo-counts is N=103. The estimated detection efficiency is ηd=0.81.

FIG. 1.

A multi-mode twin-beam state is produced through the SPDC, pumping a non-linear crystal (Type-II-Beta-Barium-Borate, BBO) with a CW laser-beam (100 mW at λpump=405 nm). The down-converted photons around the degeneracy wavelength, λd=810 nm, are spectrally selected using an interferential filter [IF, (800±20 nm)]. The resulting state can be approximated as a tensor product of independent TMSV states as |Ψ=q,λ|TMSV, where q and λ are the transverse momentum and the wavelength of one of the two photons produced, while momentum and wavelength of the other photon are fixed by energy and momentum conservation. The far field is obtained at the focal plane of a lens with fFF = 1 cm focal length, where the correlation in momentum is converted into correlation between symmetric positions. A coated glass-slide with a 2D absorbing mask, realized as a thin titanium deposition of absorption α1%, is placed in this plane. This is then imaged (magnification of 7.8) to the chip of a charge-coupled-device (CCD) camera with a nominal quantum efficiency of 95% at 810 nm and a pixel size of 13μm. We perform a 3 × 3 pixel binning, to set the resolution to 5 μm at the object plane, which matches the measured cross correlation length. The acquisition time of a single frame is 100 ms, the number of temporal modes per pixel per frame is 1011, and the number of photo-counts is N=103. The estimated detection efficiency is ηd=0.81.

Close modal

The pixel size, or, more in general, the elementary integration area in one arm, should be large enough to collect a certain number of modes. It is straightforward that if a photon is detected in a certain pixel in the probe arm, the corresponding pixel in the reference arm should be at least as large as the correlation area; otherwise, correlated photons would fall outside the pixel, representing an effective loss when pixel to pixel correlations are considered. Moreover, a photon detected close to the edge between a pixel and its neighbors has its twin photon detected with only 50% average probability in the symmetric pixel in the reference arm. Both these contributions to losses are taken into account by ηc, enclosed in η in Eqs. (6)–(8). In the conditions of our experiment, and assuming a perfect alignment, ηc is solely related to the ratio X=d/2r, with d being the pixel size and r the radius of the correlation area. The details of this model can be found in previous literature studies.2,23,24

In Fig. 2, we report the experimental NRF as a function of the spatial resolution, i.e., the minimum dimensions of a detail to be appreciated, which corresponds to the size of the integration area d. The NRF decreases with increasing d (or X), as long as the collection efficiency ηc increases and saturates the value 1ηd for d > 50 (where ηc1). In the same figure, the quantum enhancement in the sensitivity is also reported, as a function of the resolution. Of course, in general, a suitable trade-off between the resolution d and the sensitivity should be found. The dashed red curve represents the quantum advantage of the twin beam using the Subtraction estimator. It is evaluated as Ucoh/Δ2Sα, replacing in Eqs. (1) and (7) the values of NRF=1η and α with their experimentally estimated values. The solid red line represents the corresponding quantum enhancement for the Optimized estimation, e.g., Ucoh/Δ2Sα. The data-points represent, for each case, the quantum advantage estimated by the experimental frame-to-frame fluctuation in the absorption α determination, according to Eqs. (4) and (5), respectively. 300 shots and region where α1% are used. The experimental classical uncertainty to compare with is obtained by the fluctuation of the estimate in Eq. (3), where the reference NR is substituted by the mean value of the probe in the absence of the sample, NP. This estimator, using only the probe beam, reaches the lower classical bound Ucoh of Eq. (1), substituting nP with NP, e.g., considering the same probe mean energy and detection efficiency as in the quantum strategy.8 

FIG. 2.

Experimental NRF and quantum enhancement (as defined in the text) as a function of the spatial resolution in the object plane, d. The NRF (black data-series) is evaluated as NRF=Δ2(NPNR)/NP+NR for photons numbers detected in an area of size d2. Red data-series show the quantum enhancement provided by twin-beam (multimode TMSV states), both using the Subtraction estimation strategy, in Eq. (4) (dots, dashed line), or the Optimized one, in Eq. (5) (squares, solid line). The green data represent the quantity Δ2NP/NP and confirm that the statistics of photon counts is Poissonian.

FIG. 2.

Experimental NRF and quantum enhancement (as defined in the text) as a function of the spatial resolution in the object plane, d. The NRF (black data-series) is evaluated as NRF=Δ2(NPNR)/NP+NR for photons numbers detected in an area of size d2. Red data-series show the quantum enhancement provided by twin-beam (multimode TMSV states), both using the Subtraction estimation strategy, in Eq. (4) (dots, dashed line), or the Optimized one, in Eq. (5) (squares, solid line). The green data represent the quantity Δ2NP/NP and confirm that the statistics of photon counts is Poissonian.

Close modal

As we have anticipated, the quantum advantage when using the subtraction estimator, as done in previous demonstration,2 is present for η>0.5 (red dashed line in Fig. 2). It corresponds to a resolution of 3 times the correlation length, namely, 15 μm. We can conclude that, with this estimator, it is not possible, even in principle, to have quantum enhancement and a resolution close to a single coherence length, at the same time.

In this context, using the Optimized estimator is a big opportunity because the quantum advantage of the twin-beam state can also be found for smaller values of the efficiency η or equivalently whenever NRF1. In fact, the solid line in Fig. 2 shows that the quantum advantage is present also for d=5μm, which is exactly the coherence length. Moreover, this estimator performs better than the other one for any resolution, always representing the best choice for SSNQI in wide-field modality.

As mentioned, the only point that deserves attention when using the Optimized estimator is that it requires a careful characterization of the experimental setup, in order to provide a reliable value of the parameter kopt to insert in Eq. (5). This kopt is a simple function of the excess noise and the detection efficiencies in both channels. We estimated the absolute quantum efficiency using a method that can be applied with an identical setup configuration.24 We found that the performance of the Optimized estimator is not dramatically affected by the accuracy in the parameter's determination: few percent of uncertainty is enough to recover the advantage predicted by the theory.

Finally, in Fig. 3, we present a single frame experimental image of a specific absorbing mask for different spatial resolutions. The mask is realized by a thin “Φ-shaped” metallic deposition on a coated glass-slide with α1%. The resolution is set by the application of a median filter, which substitutes in each pixel (corresponding to 5μm in the object plane) the mean photon counts over a square of side d, centered in the pixel. As expected, the images obtained using the quantum protocol, i.e., using the twin-beam state, are visually better than the ones obtained by the single beam classical approach. Moreover, one can appreciate an improvement of the Optimized estimation protocol with respect to the Subtraction protocol in the residual noise level.

FIG. 3.

Comparison between single shot images for different ratios X between the pixel dimension and the correlation diameter. For each X, the direct (DIR) image is compared with the image obtained using the quantum Subtraction protocol(SUB) and the one obtained using the Optimized protocol (OPT SUB). In the upper-right panel, the direct image of the object averaged over 300 shots is reported.

FIG. 3.

Comparison between single shot images for different ratios X between the pixel dimension and the correlation diameter. For each X, the direct (DIR) image is compared with the image obtained using the quantum Subtraction protocol(SUB) and the one obtained using the Optimized protocol (OPT SUB). In the upper-right panel, the direct image of the object averaged over 300 shots is reported.

Close modal

In this Letter, we have shown a substantial improvement of the performance of the SSNQI technique with respect to previous realization.1,2,25 By studying different pure loss estimation strategies with quantum states of light in the presence of imperfections, we demonstrate that the robustness of an Optimized estimator with respect to detection losses and the link between spatial resolution and inefficiencies in detecting correlated photons imply that such an estimator produces a significant advantage also in terms of resolution. We have demonstrated that, different from the Subtraction protocol used in previous realizations, the limit to the resolution is given by the coherence area of the correlation in the far field of the SPDC process, which can be in principle reduced down to the Rayleigh limit determined by the numerical aperture of the optical system. This result represents a further step toward practical applications of quantum correlations in imaging and of using optimization techniques in this field.26–33 

This work was supported by EMPIR 17FUN01 “BeCOME”; the EMPIR initiative is co-funded by the EU H2020 and the EMPIR Participating States and by the Horizon 2020 Research and Innovation Program under Grant Agreement No. 862644 (FETopen-QUARTET).

1.
G.
Brida
,
M.
Genovese
, and
I. R.
Berchera
, “
Experimental realization of sub-shot-noise quantum imaging
,”
Nat. Photonics
4
(
4
),
227
230
(
2010
).
2.
N.
Samantaray
,
I.
Ruo-Berchera
,
A.
Meda
, and
M.
Genovese
, “
Realisation of the first sub shot noise wide field microscope
,”
Light: Sci. Appl.
6
,
e17005
(
2017
).
3.
O.
Jedrkiewicz
,
Y. K.
Jiang
,
E.
Brambilla
,
A.
Gatti
,
M.
Bache
,
L. A.
Lugiato
, and
P.
Di Trapani
, “
Detection of sub-shot-noise spatial correlation in high-gain parametric down conversion
,”
Phys. Rev. Lett.
93
,
243601
(
2004
).
4.
G.
Brida
,
L.
Caspani
,
A.
Gatti
,
M.
Genovese
,
A.
Meda
, and
I.
Ruo-Berchera
, “
Measurement of sub shot-noise spatial correlations without background subtraction
,”
Phys. Rev. Lett.
102
,
213602
(
2009
).
5.
J. L.
Blanchet
,
F.
Devaux
,
L.
Furfaro
, and
E.
Lantz
, “
Measurement of sub-shot-noise correlations of spatial fluctuations in the photon-counting regime
,”
Phys. Rev. Lett.
101
,
233604
(
2008
).
6.
E.
Brambilla
,
L.
Caspani
,
O.
Jedrkiewicz
,
L. A.
Lugiato
, and
A.
Gatti
, “
High-sensitivity imaging with multi-mode twin beams
,”
Phys. Rev. A
77
(
5
),
053807
(
2008
).
7.
M.
Genovese
, “
Real applications of quantum imaging
,”
J. Opt.
18
,
073002
(
2016
).
8.
E.
Losero
,
I.
Ruo-Berchera
,
A.
Meda
,
A.
Avella
, and
M.
Genovese
, “
Unbiased estimation of an optical loss at the ultimate quantum limit with twin-beams
,”
Sci. Rep.
8
,
7431
(
2018
).
9.
P. A.
Moreau
,
J.
Sabines-Chesterking
,
R.
Whittaker
,
S. K.
Joshi
,
P. M.
Birchall
,
A.
McMillan
,
J. G.
Rarity
, and
J. C. F.
Matthews
, “
Demonstrating an absolute quantum advantage in direct absorption measurement
,”
Sci. Rep.
7
,
6256
(
2017
).
10.
D.
Braun
,
G.
Adesso
,
F.
Benatti
,
R.
Floreanini
,
U.
Marzolino
,
M. W.
Mitchell
, and
S.
Pirandola
, “
Quantum enhanced measurements without entanglement
,”
Rev. Mod. Phys.
90
(
3
),
035006
(
2018
).
11.
A.
Monras
and
M. G.
Paris
, “
Optimal quantum estimation of loss in bosonic channels
,”
Phys. Rev. Lett.
98
(
16
),
160401
(
2007
).
12.
G.
Adesso
,
F.
Dell–Anno
,
S.
De Siena
,
F.
Illuminati
, and
L. A. M.
Souza
, “
Optimal estimation of losses at the ultimate quantum limit with non-Gaussian states
,”
Phys. Rev. A
79
(
4
),
040305
(
2009
).
13.
R.
Nair
, “
Quantum-limited loss sensing: Multiparameter estimation and Bures distance between loss channels
,”
Phys. Rev. Lett.
121
,
230801
(
2018
).
14.
A.
Monras
and
F.
Illuminati
, “
Measurement of damping and temperature: Precision bounds in Gaussian dissipative channels
,”
Phys. Rev. A
83
(
1
),
012315
(
2011
).
15.
E.
Jakeman
and
J. G.
Rarity
, “
The use of pair production processes to reduce quantum noise in transmission measurements
,”
Opt. Commun.
59
(
3
),
219
223
(
1986
).
16.
P.
Tapster
,
S.
Seward
, and
J.
Rarity
, “
Sub-shot-noise measurement of modulated absorption using parametric down-conversion
,”
Phys. Rev. A
44
,
3266
(
1991
).
17.
R.
Whittaker
,
C.
Erven
,
A.
Neville
,
M.
Berry
,
J. L.
O'Brien
,
H.
Cable
, and
J. C. F.
Matthews
, “
Absorption spectroscopy at the ultimate quantum limit from single-photon states
,”
New J. Phys.
19
(
2
),
023013
(
2017
).
18.
J.
Sabines-Chesterking
, “
Sub-shot-noise transmission measurement enabled by active feed-forward of Heralded single photons
,”
Phys. Rev. Appl.
8
,
014016
(
2017
).
19.
G.
Brida
,
M.
Genovese
,
A.
Meda
, and
I.
Ruo-Berchera
, “
Experimental quantum imaging exploiting multimode spatial correlation of twin beams
,”
Phys. Rev. A
83
,
033811
(
2011
).
20.
I. N.
Agafonov
,
M. V.
Chekhova
,
T.
Sh Iskhakov
,
A. N.
Penin
,
G. O.
Rytikov
, and
O. A.
Shcherbina
, “
Absolute calibration of photodetectors: Photocurrent multiplication versus photocurrent subtraction
,”
Opt. Lett.
36
(
8
),
1329
1331
(
2011
).
21.
M.
Bondani
,
A.
Allevi
,
G.
Zambra
,
M.
Paris
, and
A.
Andreoni
, “
Sub-shot-noise photon-number correlation in a mesoscopic twin beam of light
,”
Phys. Rev. A
76
,
013833
(
2007
).
22.
T. S.
Iskhakov
,
V. C.
Usenko
,
U. L.
Andersen
,
R.
Filip
,
M. V.
Chekhova
, and
G.
Leuchs
, “
Heralded source of bright multi-mode mesoscopic sub-Poissonian light
,”
Opt. Lett.
41
,
2149
2152
(
2016
).
23.
A.
Meda
,
E.
Losero
,
N.
Samantaray
,
F.
Scafirimuto
,
S.
Pradyumna
,
A.
Avella
,
I.
Ruo-Berchera
, and
M.
Genovese
, “
Photon-number correlation for quantum enhanced imaging and sensing
,”
J. Opt.
19
,
094002
(
2017
).
24.
A.
Meda
,
I.
Ruo-Berchera
,
I. P.
Degiovanni
,
G.
Brida
,
M. L.
Rastello
, and
M.
Genovese
, “
Absolute calibration of a charge-coupled device camera with twin beams
,”
Appl. Phys. Lett.
105
,
101113
(
2014
).
25.
J.
Sabines
,
A.
McMillan
,
P.
Moreau
,
S.
Joshi
,
S.
Knauer
,
E.
Johnston
,
J.
Rarity
, and
J.
Matthews
, “
Twin-beam sub-shot-noise raster-scanning microscope with a hybrid detection scheme
,” arXiv:1906.05331.
26.
R.
Gaiba
and
M. G.
Paris
, “
Squeezed vacuum as a universal quantum probe
,”
Phys. Lett. A
373
(
10
),
934
939
(
2009
).
27.
G.
Brida
,
I. P.
Degiovanni
,
A.
Florio
,
M.
Genovese
,
P.
Giorda
,
A.
Meda
,
M. G. A.
Paris
, and
A. P.
Shurupov
, “
Optimal estimation of entanglement in optical qubit systems
,”
Phys. Rev. A
83
(
5
),
052301
(
2011
).
28.
C.
Lupo
and
S.
Pirandola
, “
Ultimate precision bound of quantum and subwavelength imaging
,”
Phys. Rev. Lett.
117
(
19
),
190802
(
2016
).
29.
R.
Nichols
,
P.
Liuzzo-Scorpo
,
P. A.
Knott
, and
G.
Adesso
, “
Multiparameter Gaussian quantum metrology
,”
Phys. Rev. A
98
(
1
),
012114
(
2018
).
30.
C.
Lupo
,
Z.
Huang
, and
P.
Kok
, “
Quantum limits to incoherent imaging are achieved by linear interferometry
,”
Phys. Rev. Lett.
124
(
8
),
080503
(
2020
).
31.
E.
Losero
,
I.
Ruo-Berchera
,
A.
Meda
,
A.
Avella
,
O.
Sambataro
, and
M.
Genovese
, “
Quantum differential ghost microscopy
,”
Phys. Rev. A
100
(
6
),
063818
(
2019
).
32.
G.
Ortolano
,
I.
Ruo-Berchera
, and
E.
Predazzi
, “
Quantum enhanced imaging of nonuniform refractive profiles
,”
Int. J. Quantum Inf.
17
(
8
),
1941010
(
2019
).
33.
E.
Knyazev
,
F. Y.
Khalili
, and
M. V.
Chekhova
, “
Overcoming inefficient detection in sub-shot-noise absorption measurement and imaging
,”
Opt. Express
27
(
6
),
7868
7885
(
2019
).