The present computational study demonstrates that softening of an open cell nanoporous aluminum structure subjected to tensile loading can be significantly reduced when the size of ligaments and the joints that connect them in the structure is designed to be sufficiently small. It is found using molecular dynamics simulations that the softening becomes slightly slower with increasing porosity for the structures with porosity less than or equal to 72%, and stress localization is observed during softening. In contrast, for structures with more than 75% porosity, softening is much slower, and stress delocalization occurs during softening. It is argued that at relatively high porosity, softening is governed by both the ligament size and the joint size because their compliance becomes high enough to allow the overloading stress due to ligament rupture to be redistributed more effectively throughout the structure.
Skip Nav Destination
Article navigation
31 January 2011
Research Article|
January 31 2011
Ligament and joint sizes govern softening in nanoporous aluminum
A. C. To;
A. C. To
a)
Department of Mechanical Engineering and Materials Science and Department of Civil and Environmental Engineering,
University of Pittsburgh
, Pittsburgh, Pennsylvania 15261-3648, USA
Search for other works by this author on:
J. Tao;
J. Tao
Department of Mechanical Engineering and Materials Science and Department of Civil and Environmental Engineering,
University of Pittsburgh
, Pittsburgh, Pennsylvania 15261-3648, USA
Search for other works by this author on:
M. Kirca;
M. Kirca
Department of Mechanical Engineering and Materials Science and Department of Civil and Environmental Engineering,
University of Pittsburgh
, Pittsburgh, Pennsylvania 15261-3648, USA
Search for other works by this author on:
L. Schalk
L. Schalk
Department of Mechanical Engineering and Materials Science and Department of Civil and Environmental Engineering,
University of Pittsburgh
, Pittsburgh, Pennsylvania 15261-3648, USA
Search for other works by this author on:
a)
Author to whom correspondence should be addressed. Tel.: (412) 624-2052. FAX: (412) 624-0135. Electronic mail: albertto@pitt.edu.
Appl. Phys. Lett. 98, 051903 (2011)
Article history
Received:
September 11 2010
Accepted:
January 11 2011
Citation
A. C. To, J. Tao, M. Kirca, L. Schalk; Ligament and joint sizes govern softening in nanoporous aluminum. Appl. Phys. Lett. 31 January 2011; 98 (5): 051903. https://doi.org/10.1063/1.3549858
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Citing articles via
Roadmap on photonic metasurfaces
Sebastian A. Schulz, Rupert. F. Oulton, et al.
Era of entropy: Synthesis, structure, properties, and applications of high-entropy materials
Christina M. Rost, Alessandro R. Mazza, et al.
Piezoelectric phononic integrated circuits
Krishna C. Balram
Related Content
Microscopic failure behavior of nanoporous gold
Appl. Phys. Lett. (September 2005)
Mechanical properties and scaling laws of nanoporous gold
J. Appl. Phys. (January 2013)
On the scaling behavior of hardness with ligament diameter of nanoporous-Au: Constrained motion of dislocations along the ligaments
Appl. Phys. Lett. (June 2014)
Radiation induced effects on mechanical properties of nanoporous gold foams
Appl. Phys. Lett. (June 2014)
Braided structure artificial ligament from poly-l-lactide-co-caprolactone (PLA-CL) for anterior cruciate ligament injury
AIP Conference Proceedings (September 2022)