This letter reports an optically induced cell lysis device that can selectively lyse a single cell within a group of cells, a function which cannot be performed using traditional tools. This chip-scale device was made of a photoconductive material, which can induce a nonuniform electric field at a specific position under illumination of a beam spot generating a transmembrane potential in the cell. With this approach, cell lysis can be performed using the optically induced electric field. Fibroblast cells and oral cancer cells were used to demonstrate the capability of the developed chip. In addition to lysing the whole cell, the developed method also allowed one to selectively disrupt the cell membrane without damaging the nucleus. Operating parameters such as illumination power density and beam spot diameter for cell lysis were systematically investigated.

1.
X.
Chen
,
D.
Cui
,
C.
Liu
,
H.
Li
, and
J.
Chen
,
Anal. Chim. Acta
584
,
237
(
2007
).
2.
C. Y.
Lee
,
G. B.
Lee
,
J. L.
Lin
,
F. C.
Huang
, and
C. S.
Liao
,
J. Micromech. Microeng.
15
,
1215
(
2005
).
3.
S. W.
Lee
and
Y. C.
Tai
,
Sens. Actuators, A
73
,
74
(
1999
).
4.
Q.
Ramadan
,
V.
Samper
,
D.
Poenar
,
Z.
Liang
,
C.
Yu
, and
T. M.
Lim
,
Sens. Actuators B
113
,
944
(
2006
).
5.
H.
Lu
,
M. A.
Schmidt
, and
K. F.
Jensen
,
Lab Chip
5
,
23
(
2005
).
6.
K. Y.
Lu
,
A. M.
Wo
,
Y. J.
Lo
, and
K. C.
Chen
,
Biosens. Bioelectron.
22
,
568
(
2006
).
7.
H. Y.
Wang
,
A. K.
Bhunia
, and
C.
Lu
,
Biosens. Bioelectron.
22
,
582
(
2006
).
8.
D. W.
Lee
and
Y. H.
Cho
,
Sens. Actuators B
124
,
84
(
2007
).
9.
N.
Bao
and
C.
Lu
,
Appl. Phys. Lett.
92
,
214103
(
2008
).
10.
K. R.
Rau
and
A.
Guerra
 III
,
Appl. Phys. Lett.
84
,
2490
(
2004
).
11.
P.
Marmottant
and
S.
Hilgenfeldt
,
Nature (London)
423
,
153
(
2003
).
12.
P.
Prentice
,
A.
Cuschieri
,
K.
Dholakia
,
M.
Prausnitz
, and
P.
Campbell
,
Nat. Phys.
1
,
107
(
2005
).
13.
D. Di
Carlo
,
C.
Ionescu-Zanetti
,
Y.
Zhang
,
P.
Hung
, and
L. P.
Lee
,
Lab Chip
5
,
171
(
2005
).
14.
J. T.
Nevill
,
R.
Cooper
,
M.
Dueck
,
D. N.
Breslauer
, and
L. P.
Lee
,
Lab Chip
7
,
1689
(
2007
).
15.
J.
Kim
,
S. H.
Jang
,
G.
Jia
,
J. V.
Zoval
,
N. A.
Da Silva
, and
M. J.
Madou
,
Lab Chip
4
,
516
(
2004
).
16.
H.
Takamatsu
,
R.
Takeya
,
S.
Naito
, and
H.
Sumimoto
,
J. Biomech.
38
,
117
(
2005
).
17.
T.
Grahl
and
H.
Markl
,
Appl. Microbiol. Biotechnol.
45
,
148
(
1996
).
18.
Y. H.
Lin
and
G. B.
Lee
,
Biosens. Bioelectron.
24
,
572
(
2008
).
19.
C.
Wang
,
T.
Kim
,
D.
Gao
,
A.
Vaglenov
, and
B.
Kaltenboeck
,
J. Biochem. Biophys. Methods
70
,
507
(
2007
).
20.
A. T.
Ohta
,
P. Y.
Chiou
,
H. L.
Phan
,
S. W.
Sherwood
,
J. M.
Yang
,
A. N. K.
Lau
,
H. Y.
Hsu
,
A.
Jamshidi
, and
M. C.
Wu
,
IEEE J. Sel. Top. Quantum Electron.
13
,
235
(
2007
).
You do not currently have access to this content.