We report a simple and robust magnetomechanical system for direct visual observation of the DNA packaging behavior of the bacteriophage phi29 in real time. The system comprises a micron-sized magnetic bead attached to the free end of the viral DNA, a magnet and a bright-field microscope. We show that the phi29 DNA packaging activity can be observed and dynamically analyzed at the single molecular level in bright field with a relatively simple system. With this system we also visually demonstrate the phi29 motor transporting a cargo 10 000 times the viral size.
REFERENCES
1.
Y. R.
Chemla
, K.
Aathavan
, J.
Michaelis
, S.
Grimes
, P. J.
Jardine
, D. L.
Anderson
, and C.
Bustamante
, Cell
122
, 683
(2005
).2.
P.
Guo
, C.
Peterson
, and D.
Anderson
, J. Mol. Biol.
197
, 229
(1987
).3.
Y.
Tao
, N.
Olson
, W.
Xu
, D.
Anderson
, M.
Rossmann
, and T.
Baker
, Cell
95
, 431
(1998
).4.
D. E.
Smith
, S. J.
Tans
, S. B.
Smith
, S.
Grimes
, D. L.
Anderson
, and C.
Bustamante
, Nature (London)
413
, 748
(2001
).5.
P.
Guo
, J. Nanosci. Nanotechnol.
5
, 1964
(2005
).6.
S.
Guo
, D.
Shu
, M. N.
Simon
, and P.
Guo
, Gene
315
, 145
(2003
).7.
A.
Khaled
, S.
Guo
, F.
Li
, and P.
Guo
, Nano Lett.
5
, 1797
(2005
).8.
J.
Rickgauer
, D.
Fuller
, S.
Grimes
, P.
Jardine
, D.
Anderson
, and D.
Smith
, Biophys. J.
94
, 159
(2008
).9.
D.
Fuller
, J.
Rickgauer
, P.
Jardine
, S.
Grimes
, D.
Anderson
, and D.
Smith
, Proc. Natl. Acad. Sci. U.S.A.
104
, 11245
(2007
).10.
T.
Hugel
, J.
Michaelis
, C. L.
Hetherington
, P. J.
Jardine
, S.
Grimes
, J. M.
Walter
, W.
Falk
, D. L.
Anderson
, and C.
Bustamante
, PLoS Biol.
5
, e59
(2007
).11.
D.
Shu
, H.
Zhang
, J.
Jin
, and P.
Guo
, EMBO J.
26
, 527
(2007
).12.
D.
Sage
, F.
Neumann
, F.
Hediger
, S.
Gasser
, and M.
Unser
, IEEE Trans. Image Process.
14
, 1372
(2005
).13.
G.
Acharya
, C. L.
Chang
, D. D.
Doorneweerd
, E.
Vlashi
, W. A.
Henne
, L. C.
Hartmann
, P. S.
Low
, and C. A.
Savran
, J. Am. Chem. Soc.
129
, 15824
(2007
).14.
15.
P.
Guo
, S.
Grimes
, and D.
Anderson
, Proc. Natl. Acad. Sci. U.S.A.
83
, 3505
(1986
).16.
P.
Guo
, B.
Rajagopal
, D.
Anderson
, S.
Erickson
, and C.
Lee
, Virology
185
, 395
(1991
).17.
P.
Guo
, C.
Zhang
, C.
Chen
, K.
Garver
, and M.
Trottier
, Mol. Cell
2
, 149
(1998
).18.
19.
B.
Reilly
, M.
Tosi
, and D.
Anderson
, J. Virol.
16
, 1010
(1975
).20.
21.
S.
Smith
, Y.
Cui
, and C.
Bustamante
, Science
271
, 795
(1996
).22.
J.
Fisher
, J.
Cummings
, K.
Desai
, L.
Vicci
, B.
Wilde
, K.
Keller
, C.
Weigle
, G.
Bishop
, R.
Taylor
, C.
Davis
, R.
Boucher
, E.
O’Brien
, and R.
Superfine
, Rev. Sci. Instrum.
76
, 053711
(2005
).23.
See EPAPS Document No. E-APPLAB-93-014842 for the calibration of applied magnetic force and two movie files. For more information on EPAPS, see http://www.aip.org/pubservs/epaps.html.
© 2008 American Institute of Physics.
2008
American Institute of Physics
You do not currently have access to this content.