A stripline-type near-field microwave probe is microfabricated for microwave impedance microscopy. Unlike the poorly shielded coplanar probe that senses the sample tens of microns away, the stripline structure removes the stray fields from the cantilever body and localizes the interaction only around the focused-ion beam deposited Pt tip. The approaching curve of an oscillating tip toward bulk dielectrics can be quantitatively simulated and fitted to the finite-element analysis result. The peak signal of the approaching curve is a measure of the sample dielectric constant and can be used to study unknown bulk materials.
REFERENCES
1.
B. T.
Rosner
and D. W.
van der Weide
, Rev. Sci. Instrum.
73
, 2505
(2002
).2.
S. M.
Anlage
, V. V.
Talanov
, and A. R.
Schwartz
, Scanning Probe Microscopy: Electrical and Electromechanical Phenomena at the Nanoscale
, (Springer
, New York
, 2006
), pp. 207
–245
.3.
A.
Imtiaz
and S. M.
Anlage
, Ultramicroscopy
94
, 209
(2003
).4.
M.
Tabib-Azar
, D. -P.
Su
, A.
Pohar
, S. R.
LeClair
, and G.
Ponchak
, Rev. Sci. Instrum.
70
, 1725
(1999
).5.
M.
Golosovsky
and D.
Davidov
, Appl. Phys. Lett.
68
, 1579
(1996
).6.
J.
Bae
, T.
Okamoto
, T.
Fujii
, K.
Mizuno
, and T.
Nozokido
, Appl. Phys. Lett.
71
, 3581
(1997
).7.
S.
Hong
, J.
Kim
, W.
Park
, and K.
Lee
, Appl. Phys. Lett.
80
, 524
(2002
).8.
T.
Wei
, X. -D.
Xiang
, W. G.
Wallace-Freedman
, and P. G.
Schultz
, Appl. Phys. Lett.
68
, 3506
(1996
).9.
C.
Gao
, F.
Duewer
, and X. D.
Xiang
, Appl. Phys. Lett.
75
, 3005
(1999
).10.
Z.
Wang
, M. A.
Kelly
, and Z. X.
Shen
, J. Appl. Phys.
92
, 808
(2002
).11.
A.
Imtiaz
, T.
Baldwin
, H. T.
Nembach
, T. M.
Wallis
, and P.
Kabos
, Appl. Phys. Lett.
90
, 243105
(2007
).12.
K.
Lai
, M. B.
Ji
, N.
Leindecker
, M. A.
Kelly
, and Z. X.
Shen
, Rev. Sci. Instrum.
78
, 063702
(2007
).13.
K.
Lai
, W.
Kundhikanjana
, M.
Kelly
, and Z. X.
Shen
, Rev. Sci. Instrum.
79
, 063703
(2008
).14.
M.
Tabib-Azar
and Y.
Wang
, IEEE Trans. Microwave Theory Tech.
52
, 971
(2004
).15.
B. T.
Rosner
, T.
Bork
, V.
Agrawal
, and D. W.
van der Weide
, Sens. Actuators, A
102
, 185
(2002
).16.
COMSOL, Inc., Palo Alto, CA.
17.
A.
Tselev
, S. M.
Anlage
, H. M.
Christen
, R. L.
Moreland
, V. V.
Talanov
, and A. R.
Schwartz
, Rev. Sci. Instrum.
74
, 3167
(2003
).18.
The sapphire sample used in this study is anisotropic with in one axis and 11.4 in the other. The microwave probe measures the effective response, which is equivalent to an isotropic dielectric of .
19.
© 2008 American Institute of Physics.
2008
American Institute of Physics
You do not currently have access to this content.