This Letter details a pioneering study on the design and nanofabrication process of a thermoelectric infrared radiation detector using a suspended polyimide membrane. The research includes a comprehensive analysis of thermoelectric doped Bi2Te3 thin films, comparing their expected performance regarding noise and specific detectivity with other infrared detectors, particularly those in the silicon sector. Experimental results and calculations shed light on responsivity and time constants. In the absence of absorption layers, specific detectivity values for visible and near infrared radiation are measured at 9.2 × 107 and 2.9 × 107 , respectively, with a time constant nearing 20 ms. Calculations show that introducing an optimized absorption layer with ε = 1 significantly improves specific detectivity, reaching 9.0 × 108 . Subsequent calculations also show that further enhancement can be obtained by etching the polyimide membrane to a 1-micron thickness, resulting in an exceptional specific detectivity value of 8.4 × 109 , placing it among the best in the current state-of-the-art.
Skip Nav Destination
Article navigation
8 July 2024
Research Article|
July 10 2024
Thermal detector based on a suspended polyimide membrane for infrared radiation applications
Special Collection:
Advances in Thermal Phonon Engineering and Thermal Management
D. Bourgault
;
D. Bourgault
a)
(Conceptualization, Funding acquisition, Methodology, Project administration, Supervision, Writing – original draft)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
a)Author to whom correspondence should be addressed: [email protected]
Search for other works by this author on:
G. Paul
;
G. Paul
(Conceptualization, Formal analysis, Investigation, Validation)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
C. Latargez
;
C. Latargez
(Conceptualization, Formal analysis, Investigation, Methodology, Validation)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
G. Moiroux
;
G. Moiroux
(Conceptualization, Formal analysis, Investigation, Methodology, Validation)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
D. Jegouso;
D. Jegouso
(Formal analysis, Investigation, Methodology)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
C. Felix
;
C. Felix
(Formal analysis, Investigation, Methodology)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
C. Guttin
;
C. Guttin
(Formal analysis, Investigation, Methodology)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
J.-L. Garden
J.-L. Garden
(Conceptualization, Data curation, Funding acquisition, Project administration, Supervision, Writing – original draft)
1
University Grenoble Alpes, Institut Néel
, F-38042 Grenoble, France
2
Centre National de la Recherche Scientifique/Institut Néel
, 25 Avenue des Martyrs, BP 166, 38042 Grenoble Cedex 9, France
Search for other works by this author on:
a)Author to whom correspondence should be addressed: [email protected]
Appl. Phys. Lett. 125, 022203 (2024)
Article history
Received:
April 12 2024
Accepted:
June 22 2024
Citation
D. Bourgault, G. Paul, C. Latargez, G. Moiroux, D. Jegouso, C. Felix, C. Guttin, J.-L. Garden; Thermal detector based on a suspended polyimide membrane for infrared radiation applications. Appl. Phys. Lett. 8 July 2024; 125 (2): 022203. https://doi.org/10.1063/5.0213691
Download citation file:
Pay-Per-View Access
$40.00
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
133
Views
Citing articles via
Roadmap on photonic metasurfaces
Sebastian A. Schulz, Rupert. F. Oulton, et al.
Kirchhoff's law violation within the main solar wavelength range
Yubin Park, Shanhui Fan
Integrated photonics beyond communications
Chong Zhang, Minh A. Tran, et al.
Related Content
Experimental setup for thermal measurements at the nanoscale using a SThM probe with niobium nitride thermometer