In this study, we presented a high-resolution linear-scanning photoacoustic computed tomography (PACT) system with a focus-tunable fiber-laser ultrasound sensor. By bending the fiber laser into a curvature radius of 25 mm, an 85 μm × 150 μm in-plane resolution and a 300 μm elevational resolution were achieved. The elevational resolution was ∼3 times better than the previously reported value. Hair phantoms at multiple depths from 2 cm to 6 cm were clearly observed by tuning the bending curvature. Additionally, the fiber-laser-based PACT system showed its capability for high-resolution imaging of small animals based on the images of abdominal subcutaneous vasculatures from a rat. With the excitation light delivered by a fiber bundle and the ultrasound detected by a fiber laser, this all-fiber linear-scanning PACT system holds great potential for photoacoustic imaging in preclinical and clinical applications.

1.
L. V.
Wang
and
J.
Yao
,
Nat. Methods
13
(
8
),
627
(
2016
).
2.
P. K.
Upputuri
and
M.
Pramanik
,
J. Biomed. Opt.
24
(
4
),
1
(
2019
).
3.
R. J.
Zemp
,
R.
Bitton
,
M.-L.
Li
,
K. K.
Shung
,
G.
Stoica
, and
L. V.
Wang
,
J. Biomed. Opt.
12
(
1
),
010501
(
2007
).
4.
X.
Wang
,
Y.
Pang
,
G.
Ku
,
X.
Xie
,
G.
Stoica
, and
L. V.
Wang
,
Nat. Biotechnol.
21
(
7
),
803
(
2003
).
5.
S.
Gottschalk
,
O.
Degtyaruk
,
B.
Mc Larney
,
J.
Rebling
,
M. A.
Hutter
,
X. L.
Deán-Ben
,
S.
Shoham
, and
D.
Razansky
,
Nat. Biomed. Eng.
3
(
5
),
392
(
2019
).
6.
A.
Jain
,
K. J.
Prashanth
,
A. K.
Sharma
,
A.
Jain
, and
P. N.
Rashmi
,
Polym. Eng. Sci.
55
(
7
),
1589
(
2015
).
7.
M.
Pramanik
,
G.
Ku
, and
L. V.
Wang
,
J. Biomed. Opt.
14
(
2
),
024028
(
2009
).
8.
X.
Lin
,
C.
Liu
,
J.
Meng
,
X.
Gong
,
R.
Lin
,
M.
Sun
, and
L.
Song
,
J. Biomed. Opt.
23
(
5
),
050501
(
2018
).
9.
J.
Liu
,
L.
Yuan
,
J.
Lei
,
W.
Zhu
,
B.
Cheng
,
Q.
Zhang
,
Y.
Song
,
C.
Chen
, and
H.
Xiao
,
Opt. Lett.
42
(
13
),
2459
(
2017
).
10.
J. A.
Guggenheim
,
J.
Li
,
T. J.
Allen
,
R. J.
Colchester
,
S.
Noimark
,
O.
Ogunlade
,
I. P.
Parkin
,
I.
Papakonstantinou
,
A. E.
Desjardins
,
E. Z.
Zhang
, and
P. C.
Beard
,
Nat. Photonics
11
(
11
),
714
(
2017
).
11.
H.
Grün
,
T.
Berer
,
P.
Burgholzer
,
R.
Nuster
, and
G.
Paltauf
,
J. Biomed. Opt.
15
(
2
),
021306
(
2010
).
12.
G.
Wissmeyer
,
D.
Soliman
,
R.
Shnaiderman
,
A.
Rosenthal
, and
V.
Ntziachristos
,
Opt. Lett.
41
(
9
),
1953
(
2016
).
13.
G.
Wissmeyer
,
M. A.
Pleitez
,
A.
Rosenthal
, and
V.
Ntziachristos
,
Light Sci. Appl.
7
(
1
),
53
(
2018
).
14.
B.
Dong
,
C.
Sun
, and
H.
Zhang
,
IEEE Trans. Biomed. Eng.
64
(
1
),
4
(
2017
).
15.
X.
Bai
,
Y.
Qi
,
Y.
Liang
,
J.
Ma
,
L.
Jin
, and
B. O.
Guan
,
Biomed. Opt. Express
10
(
5
),
2504
(
2019
).
16.
C.
Kim
,
T. N.
Erpelding
,
L.
Jankovic
,
M. D.
Pashley
, and
L. V.
Wang
,
Biomed. Opt. Express
1
(
1
),
278
284
(
2010
).
17.
R.
Ulrich
,
S.
Rashleigh
, and
W.
Eickhoff
,
Opt. Lett.
5
(
6
),
273
(
1980
).
18.
M.
Xu
and
L. V.
Wang
,
Phys. Rev. E
71
,
016706
(
2005
).
19.
C.
Cai
,
X.
Wang
,
K.
Si
,
J.
Qian
,
J.
Luo
, and
C.
Ma
,
Biomed. Opt. Express
10
(
7
),
3447
(
2019
).
20.
Y.
Wang
,
D.
Wang
,
Y.
Zhang
,
J.
Geng
,
J. F.
Lovell
, and
J.
Xia
,
Opt. Lett.
41
(
1
),
127
(
2016
).
21.
J.
Laufer
,
E.
Zhang
,
G.
Raivich
, and
P.
Beard
,
Appl. Opt.
48
(
10
),
D209
D306
(
2009
).
22.
L.
Song
,
K.
Maslov
,
R.
Bitton
,
K. K.
Shung
, and
L.
Wang
,
J. Biomed. Opt.
13
(
5
),
054028
(
2008
).
23.
A. P.
Jathoul
,
J.
Laufer
,
O.
Ogunlade
,
B.
Treeby
,
B.
Cox
,
E.
Zhang
,
P.
Johnson
,
A. R.
Pizzey
,
B.
Philip
,
T.
Marafioti
,
M. F.
Lythgoe
,
R. B.
Pedley
,
M. A.
Pule
, and
P.
Beard
,
Nat. Photonics
9
(
4
),
239
(
2015
).
24.
J.
Xia
,
W.
Chen
,
K.
Maslov
,
M.
Anastasio
, and
L.
Wang
,
J. Biomed. Opt.
19
(
1
),
016003
(
2014
).
You do not currently have access to this content.