Conventional semi-infinite solution for extracting blood flow index (BFI) from diffuse correlation spectroscopy (DCS) measurements may cause errors in estimation of BFI (αDB) in tissues with small volume and large curvature. We proposed an algorithm integrating Nth-order linear model of autocorrelation function with the Monte Carlo simulation of photon migrations in tissue for the extraction of αDB. The volume and geometry of the measured tissue were incorporated in the Monte Carlo simulation, which overcome the semi-infinite restrictions. The algorithm was tested using computer simulations on four tissue models with varied volumes/geometries and applied on an in vivo stroke model of mouse. Computer simulations shows that the high-order (N ≥ 5) linear algorithm was more accurate in extracting αDB (errors < ±2%) from the noise-free DCS data than the semi-infinite solution (errors: −5.3% to −18.0%) for different tissue models. Although adding random noises to DCS data resulted in αDB variations, the mean values of errors in extracting αDB were similar to those reconstructed from the noise-free DCS data. In addition, the errors in extracting the relative changes of αDB using both linear algorithm and semi-infinite solution were fairly small (errors < ±2.0%) and did not rely on the tissue volume/geometry. The experimental results from the in vivo stroke mice agreed with those in simulations, demonstrating the robustness of the linear algorithm. DCS with the high-order linear algorithm shows the potential for the inter-subject comparison and longitudinal monitoring of absolute BFI in a variety of tissues/organs with different volumes/geometries.
Skip Nav Destination
Article navigation
12 May 2014
Research Article|
May 13 2014
Extraction of diffuse correlation spectroscopy flow index by integration of Nth-order linear model with Monte Carlo simulation
Yu Shang;
Yu Shang
1Department of Biomedical Engineering,
University of Kentucky
, Lexington, Kentucky 40506, USA
Search for other works by this author on:
Ting Li;
Ting Li
1Department of Biomedical Engineering,
University of Kentucky
, Lexington, Kentucky 40506, USA
2
State Key Laboratory for Electronic Thin Film and Integrated Device, University of Electronic Science and Technology of China
, Chengdu 610054, People's Republic of China
Search for other works by this author on:
Lei Chen;
Lei Chen
a)
3Department of Neurosurgery,
University of Kentucky
, Lexington, Kentucky 40536, USA
Search for other works by this author on:
Yu Lin;
Yu Lin
1Department of Biomedical Engineering,
University of Kentucky
, Lexington, Kentucky 40506, USA
Search for other works by this author on:
Michal Toborek;
Michal Toborek
b)
3Department of Neurosurgery,
University of Kentucky
, Lexington, Kentucky 40536, USA
Search for other works by this author on:
Guoqiang Yu
Guoqiang Yu
c)
1Department of Biomedical Engineering,
University of Kentucky
, Lexington, Kentucky 40506, USA
Search for other works by this author on:
a)
Current address: Neuroscience, Icahn School of Medicine at Mount Sinai, New York 10029, USA.
b)
Current address: Department of Biochemistry and Molecular Biology, University of Miami School of Medicine, Miami, Florida 33136, USA.
c)
Electronic mail: guoqiang.yu@uky.edu
Appl. Phys. Lett. 104, 193703 (2014)
Article history
Received:
March 05 2014
Accepted:
April 30 2014
Citation
Yu Shang, Ting Li, Lei Chen, Yu Lin, Michal Toborek, Guoqiang Yu; Extraction of diffuse correlation spectroscopy flow index by integration of Nth-order linear model with Monte Carlo simulation. Appl. Phys. Lett. 12 May 2014; 104 (19): 193703. https://doi.org/10.1063/1.4876216
Download citation file:
Sign in
Don't already have an account? Register
Sign In
You could not be signed in. Please check your credentials and make sure you have an active account and try again.
Sign in via your Institution
Sign in via your InstitutionPay-Per-View Access
$40.00