Here, thermal stabilities for Ohmic contact properties of Pt, Au, and Pd on the same hydrogen-terminated diamond (H-diamond) epitaxial layer are investigated. A long-term annealing process is performed with an annealing temperature and time of 400 °C and 8 h, respectively. Before annealing, good Ohmic contact properties are observed for only two contacts of the Pt/H-diamond and Pd/H-diamond with specific contact resistivity (ρC) values of 2.7 × 10−3 Ω cm2 and 2.6 × 10−4 Ω cm2, respectively. After long-term annealing, all three contacts on the H-diamond show good Ohmic contact properties. The ρC values for the Pt/H-diamond and Au/H-diamond are 3.1 × 10−2 Ω cm2 and 4.2 × 10−4 Ω cm2, respectively. They are higher than that of the Pd/H-diamond (1.1 × 10−4 Ω cm2). Therefore, low ρC and good thermal stability for the Pd/H-diamond are achieved. This is meaningful for pushing forward the development of H-diamond-based electronic devices for high-temperature applications.
Semiconductor diamonds have many remarkable intrinsic properties, such as wide bandgap energy (5.47 eV), highest thermal conductivity (22 W/cm K), high carrier mobilities (4500 cm2/V s and 3800 cm2/V s for electrons and holes, respectively), and high breakdown electric field (10 MV/cm).1–4 Therefore, diamond appears promising for producing next-generation high-power, high-frequency, and high-temperature electronic devices.5–7 Currently, the hydrogen-terminated diamond (H-diamond) and bulk-doped diamond (such as boron-doped and phosphorous-doped) are used for the fabrication of metal–oxide–semiconductor field-effect transistors (MOSFETs).8–13 However, current outputs of bulk-doped diamond-based MOSFETs are quite low (<1.6 mA/mm) due to the high activation energies of dopants.8,9 In contrast, H-diamond-based MOSFETs have much higher current densities, thanks to their good surface conductivity with a sheet hole density of ∼1014/cm2.10 The current output maximum for H-diamond-based MOSFETs was as high as 1350 mA/mm.10 Furthermore, they could operate well with a cutoff frequency and breakdown voltage of 70 GHz and 2000 V, respectively.11,12 These electrical properties make H-diamond-based MOSFETs promising for high-power and high-frequency applications.
For H-diamond-based MOSFETs, another important consideration is high-temperature applications. Recently, it was reported that H-diamond-based MOSFETs could work well at temperatures as high as 400 °C.13 In order to further improve the performance of H-diamond-based MOSFETs at high-temperature, it is important to find a suitable metal electrode on the H-diamond to form Ohmic contacts with a low specific contact resistivity (ρC) and good thermal stability. In order to obtain Ohmic contacts on the p-type H-diamond, a metal electrode with a work function (ΦM) larger than that of the H-diamond (ΦM: 4.9 eV) is required.14 Until now, several metals such as Au (ΦM: 5.10 eV), Pt (ΦM: 5.65 eV), Pd (ΦM: 5.12 eV), and 500 °C-annealed Ti/Au (ΦM: 4.33/5.10 eV) have been used as Ohmic contacts on the H-diamond.15–20 However, their thermal stability has been rarely reported. On the other hand, Ohmic contacts on the H-diamond are affected by the quality of the H-diamond epitaxial layer, which depends on the growth conditions. The contact properties of metal electrodes on different H-diamond epitaxial layers are therefore difficult to be compared with each other.
In this study, Pt, Au, and Pd electrodes are formed on the same H-diamond epitaxial layer. Their specific contact resistivities and thermal stabilities at the maximum operation temperature (400 °C) of H-diamond MOSFETs will be investigated and discussed.
Three electrodes were formed separately on the H-diamond. Figure 1 shows the formation routines of the Pt contact on the H-diamond epitaxial layer. The Ib-type single-crystalline diamond (100) substrate with dimensions of 3.0 × 3.0 × 1.0 mm3 was cleaned in a mixed acid (H2SO4 and HNO3 with a volume ratio of 1:1) at 300 °C for 3 h [Fig. 1(a)]. The H-diamond was homoepitaxially grown with a thickness of 150 nm using a microwave plasma-enhanced chemical vapor deposition system (No. AX5200S, Seki Technotron Corp., Tokyo, Japan) [Fig. 1(b)]. The CH4 flow rate, H2 flow rate, chamber pressure, growth temperature, and growth time were 0.5 SCCM, 500 SCCM, 80 Torr, 900–940 °C, and 1.5 h, respectively. Surface roughness of the H-diamond epitaxial layer was previously reported to be around 1.2 nm via an atomic force microscopy technique.21 Its sheet hole density and mobility were confirmed to be around ∼1013/cm2 and 90 cm2/V s, respectively, using the Hall measurement system. For each following step of the key-pattern formation [Fig. 1(c)], mesa-structure formation [Fig. 1(d)], contact electrode formation [Fig. 1(e)], and coating, exposing, developing, and lifting-off of photoresists were performed. The sample was sequentially coated with LOR5A and AZ5214E positive photoresists using a spin-coater with a rotation rate and time of 7000 rpm and 1 s, respectively. The baking temperature and time for the LOR5A/AZ5214E photoresists were 180/110 °C and 5/2 min, respectively. After being exposed to a mask-less photolithography system (No. DL-1000/NC2P, Nanosystem Solutions, Inc. Tokyo, Japan) with a dose energy of 250 mJ/cm2, the sample was developed in a 2.38% tetramethyl ammonium hydroxide (TMAH) solution for 90 s.
Cross-shaped key-patterns [Fig. 1(c)] were formed using a J-sputter system (No. CFS-4EP-LL, Shibaura Mechatronics Corp., Kanagawa, Japan) at an Ar atmosphere for calibrating the positions of the mesa-structure [Fig. 1(d)] and Ohmic contacts [Fig. 1(e)]. The mesa-structure for the H-diamond was formed using a capacitively coupled-plasma reactive ion etching system (No. RIE-200NL, Samco Inc., Kyodo, Japan) [Fig. 1(d)]. The plasma power, O2 flow rate, and etching time were 50 W, 100 SCCM, and 90 s, respectively. The Pt metal covered by the Ti/Au bilayer on the H-diamond was formed via an e-beam evaporation system (No. RDEB-1206K, R-DEC. Co., Ltd., Ibaraki, Japan) under a vacuum condition of ∼10−5 Pa [Fig. 1(e)]. After lifting-off of the photoresists in an n-methylpryolidone (NMP) solution for 3 h at room temperature, the Au and Pd (covered by the Ti/Au) electrodes were formed with the same evaporation system separately. The Ti/Au cover layers are important to prevent oxidization of Pt and Pd in air. Thicknesses of the Pt/Ti/Au, Au, and Pd/Ti/Au metals were 10/20/100, 100, and 10/20/100 nm, respectively. After finishing the formation process, the sample was annealed at 400 °C for as long as 8 h under a low vacuum condition (∼5.0 Pa) via a rapid thermal annealing system (No. QHC-P410, Advance Riko, Inc., Kanagawa, Japan). Then, the sample was exposed to atmosphere for more than 24 h to saturate the conductivity of the H-diamond surface.22 Electrical properties of the three contacts on the H-diamond were characterized using a four-probe system (Vector Semiconductor Co., Ltd., Tokyo, Japan) at room temperature.
Figure 2(a) shows the surface morphology of the three contacts on the H-diamond. The length and width for each electrode are the same, 100 µm. No electrodes peeled-off after the formation process. There are eight different interspace (d) values between two adjacent electrodes for each contact. Interspace distances between them are confirmed via a scanning electron microscope technique after electrical property measurement [Fig. 2(b)]. The d values are in the range of 5.0 µm–18.5 µm, 4.8 µm–18.8 µm, and 4.9 µm–19.0 µm for the Pt, Au, and Pd contacts, respectively.
Figures 3(a) and 3(c) show the current–voltage characteristics of the Pt/H-diamond before and after annealing at 400 °C for 8 h, respectively. The voltage was changed from −0.5 V to 0.5 V. The current was normalized by an electrode width of 100 µm. All current–voltage curves have linear characteristics, implying good Ohmic contact properties for the Pt/H-diamond before and after annealing. When d is 5.0 µm, the current is 6.7 × 10−4 A/mm at a voltage of 0.5 V before annealing, which is higher than that (1.7 × 10−4 A/mm) after annealing. Total resistance (RT) values for the Pt/H-diamond at d = 5.0 µm before and after annealing are calculated to be 7.5 × 102 Ω mm and 2.9 × 103 Ω mm, respectively. The increase in RT after annealing is possibly due to the deterioration of surface conductivity of the H-diamond.22 Figures 3(b) and 3(d) show RT as functions of d for the Pt/H-diamond before and after annealing, respectively. The black triangle and red square spots represent RT at voltages of −0.5 V and 0.5 V, respectively. With the change in d from 5.0 µm to 18.5 µm, RT increases. RT between two adjacent Ohmic electrodes is twice the contact resistance (RC) and surface resistance (RS), as shown in the following equation:23,24
where Rsheet is the surface sheet resistance. If 2RC for the two adjacent Ohmic electrodes are stable, the increase in RT with a change in d is attributed to RS. By fitting the spots in Figs. 3(b) and 3(d), the 2RC values (the intercepts of the y-axis for the fitting lines) for the Pt/H-diamond before and after annealing are determined to be 3.5 × 102 Ω mm and 1.9 × 103 Ω mm, respectively. Their Rsheet values extracted from the slopes of the fitting lines are determined to be 1.1 × 105 Ω/□ and 2.9 × 105 Ω/□, respectively. Therefore, Rsheet for the H-diamond increases after long-term annealing, which can be ascribed to the damage of the surface adsorbates and C–H bonds on the H-diamond.22 Their twice the transfer length (2LT) (the intercept of the x-axis for the fitting lines) is calculated to be 3.1 μm and 6.6 µm, respectively. Therefore, the ρC values for the Pt/H-diamond before and after annealing are calculated to be 2.7 × 10−3 Ω cm2 and 3.1 × 10−2 Ω cm2, respectively, based on the following equation:23,24
Figures 4(a) and 4(b) show the current–voltage characteristics of the Au/H-diamond before and after annealing, respectively. Before annealing, there were not good linear relationships for all the curves. Meanwhile, the current at a voltage of 0.5 V is disordered with the increase in d from 4.8 µm to 18.8 µm. The poor Ohmic contact properties for the Au/H-diamond before annealing are possibly attributed to the adhesion issue of Au on the H-diamond.25 After annealing at 400 °C for 8 h, there are good linear relationships for the current–voltage curves, as shown in Fig. 4(c). The current at d = 4.8 µm is 4.2 × 10−4 A/mm, which is one order larger than that before annealing. Figures 4(b) and 4(d) show RT as functions of d for the Au/H-diamond before and after annealing, respectively. Before annealing, the black triangle (the RT calculated at −0.5 V) and red square (the RT calculated at −0.5 V) spots are quite different from each other at the same d value. It is difficult to deduce the 2RC and 2LT values. After annealing, the black triangle and red square spots are in good agreement with each other. Therefore, 2RC, Rsheet, and 2LT for the Au/H-diamond after annealing are calculated to be 2.1 × 102 Ω mm, 2.7 × 105 Ω/□, and 0.8 µm, respectively. Its ρC can be calculated, based on Eq. (2), to be 4.2 × 10−4 Ω cm2, which is lower than those of the Pt/H-diamond before (2.7 × 10−3 Ω cm2) and after annealing (3.1 × 10−2 Ω cm2). However, it is larger than that of the 600 °C-annealed Au/H-diamond (4.3 × 10−5 Ω cm2).26 Therefore, a higher annealing temperature for the Au/H-diamond contact would further decrease its ρC.
Figures 5(a) and 5(c) show the current–voltage characteristics of the Pd/H-diamond before and after annealing, respectively. For all current–voltage curves, there are linear characteristics. Good Ohmic contacts for the Pd/H-diamond are obtained. Before annealing, the current at a voltage of 0.5 V is 1.2 × 10−3 A/mm at d = 4.9 µm. After annealing, it decreases to 3.6 × 10−4 A/mm. RT as functions of d for the Pd/H-diamond before and after annealing are shown in Figs. 5(b) and 5(d), respectively. The black triangle (the RT calculated at −0.5 V) and red square (the RT calculated at −0.5 V) spots are in good agreement with each other. By fitting them, 2RC for the Pd/H-diamond before and after annealing is determined to be 86.7 Ω mm and 110.0 Ω mm, respectively. Rsheet for the H-diamond surfaces is 7.5 × 104 Ω/□ and 2.6 × 105 Ω/□, respectively. The 2LT values are deduced to be 1.2 μm and 0.4 µm, respectively. The ρC values for the Pd/H-diamond before and after annealing are calculated, based on Eq. (3), to be 2.6 × 10−4 Ω cm2 and 1.1 × 10−4 Ω cm2, respectively, which are lower than that of the recently reported value (8 ± 1 × 10−4 Ω cm2) for the Pd/H-diamond at room temperature.20
Figures 6(a) and 6(b) summarize the annealing effects on RC and ρC for three contacts on the H-diamond, respectively. Because of the poor Ohmic contact for the Au/H-diamond before annealing, its RC and ρC are not obtained. Annealing makes the RC increase to more than five times that before annealing for the Pt/H-diamond. However, annealing does not affect RC of the Pd/H-diamond greatly. Before annealing, RC for the Pd/H-diamond is lower than that for the Pt/H-diamond. After annealing, it is still much lower than those of the Pt/H-diamond and Au/H-diamond. Annealing makes ρC for the Pt/H-diamond increase by around one order of magnitude compared with that before annealing [Fig. 6(b)]. It is also much larger than those of the Au/H-diamond and Pd/H-diamond. The ρC for the Pd/H-diamond after annealing is a little lower than that before annealing and is also the lowest one among the three contacts. Based on the above comparisons for the three contacts shown in Figs. 6(a) and 6(b), it can be concluded that annealing degrades and improves the contact properties of the Pt/H-diamond and Au/H-diamond, respectively. After the long-term annealing process, the contact properties of the Pd/H-diamond are still very good and stable. Therefore, Pd is a good choice as an Ohmic contact electrode to push forward the development of H-diamond-based electronic devices for high-temperature applications.
In conclusion, the contact properties and thermal stabilities of Pt, Au, and Pd contacts on the same H-diamond epitaxial layer were investigated and discussed. Before annealing, only the Pt/H-diamond and Pd/H-diamond showed good Ohmic contact properties, with a ρC of 2.7 × 10−3 Ω cm2 and 2.6 × 10−4 Ω cm2, respectively. After annealing at 400 °C for as long as 8 h, a good Ohmic contact was observed for all three contacts, with a ρC values of 3.1 × 10−2 Ω cm2, 4.2 × 10−4 Ω cm2, and 1.1 × 10−4 Ω cm2, respectively. The long-term annealing process degrades and improves the contact properties of the Pt/H-diamond and Au/H-diamond, respectively. They were still stable for the Pd/H-diamond and were better than those of the other two contacts.
DATA AVAILABILITY
The data that support the findings of this study are available from the corresponding author upon reasonable request.
This work was supported by the KAKENHI Project, under Grant Nos. JP18K13806 and JP16H06419, the Leading Initiative for Excellent Young Researchers Program Project, the NIMS Nanofabrication Platform of the Nanotechnology Platform Project sponsored by the Ministry of Education, Culture, Sports, and Technology, Japan, and the Murata Science Foundation. It was supported partly by the National Key Research and Development Program of China (Grant No. 2016YFE0133200).