A frequency sweeper and resonant frequency tracer have been developed to detect the resonant frequency on the microcantilever sensor. Frequency sweepers and frequency trackers are very important to develop microcantilever sensors, especially measurements of sensitivity, response time, and reproducibility. This developed system uses Arduino as a microcontroller to control AD9850 direct digital synthesizer (DDS) to produce sinusoidal voltage signal with an amplitude of ± 0.5 volts at a certain frequency. This signal was amplified up to ± 10 volts, then transmitted to the piezoelectric in order to vibrate the microcantilever sensor in a certain frequency. The microcantilever resonant frequency can be determined by frequency sweeper when the signal reaches its maximum amplitude. Frequency tracer was developed to record changes in the resonant frequency of the microcantilever due to objects mounted on the surface of the microcantilever. The frequency measurement results are validated by comparing its outputs to the other devices which was developed by Shizuoka University. The final results that the microcantilever has a natural frequency of 36.41 kHz.

1.
N.
Ratno
.
Simulasi Deteksi Mikrokantilever Sensor Berbasis Persamaan Euler-Bernoulli
.
Jurnal Ilmiah Elite Elektro
,
2
(
1
):
25
29
(
2011
).
2.
F.
Aan
.
Piezoresistive Microcantilever Sebagai Sensor Dengan Sensitifitas Tinggi
.
Seminar Nasional Sains Dan Teknologi
, Issn: (
2014
).
3.
H.
Karolyn
and
T.
Thundat
.
Microcantilever Biosensors
.
Methods
37
,
57
64
(
2005
).
4.
N.
Ratno
,
L.
Aprilia
.
Penggunaan Mikrokantilever Piezoresistif Untuk Aplikasi Sensor Lingkungan Dan Biologi
,
Prosiding Insinas.
31
36
(
2012
).
5.
A.
Lia
.
Respon Mikrokantilever Piezoresistif Mode Statis Dan Dinamis Terhadap Gas
. Tesis.
Depok
:
Universitas Indonesia
(
2014
).
6.
C.
Wang
. Ultrasensitive biochemical sensors based on microcantilevers of atomic force microscope.
Elsevier Inc
(
2007
).
7.
Y.
Lim
,
A. Z.
Kouzani
,
W.
Duan
, and
A.
Kaynak
. (
2010
).
Effects of Design Parameters on Sensitivity of Microcantilever Biosensors
.
The 2010 IEEE/ICME International Conference on Complex Medical Engineering
,
Gold Coast, Australia
.
8.
A.
Nuning
,
L.
Aprilia
,
R.
Nuryadi
.
Piezoresistive Microcantilever-Based Gas Sensor Using Dynamic Mode Measurement
. 978-1-4673-5785-2/13 (
2013
).
9.
A.
Lia
. “
Influence of water vapor on CO detection using a resonant microcantilever functionalized by Al-doped ZnO nanorods
,”
Jpn. J. Appl. Phys.
, vol.
58
, pp.
SBBH09_1-5
(
2019
).