Heat loss of receiver tubes is related with the radiant emittance of absorbers. This parameter can be obtained using an IR spectrophotometer to measure the spectral hemispherical reflectance of absorber tube samples which requires the breaking of a receiver tube. Nevertheless, radiant emittance can be also obtained indirectly testing a complete receiver tube in a test device to measure its heat losses by radiation. This paper shows results of tests performed to different receivers applying both methodologies to calculate their emittance. One conclusion is the importance of performing measurements in an evacuated atmosphere when the non-destructive method is applied; this is to eliminate convective heat transfer to the surroundings, especially at low temperature when convective heat losses may have a much greater influence on the accuracy of emittance results.
Skip Nav Destination
,
,
,
Article navigation
25 July 2019
SolarPACES 2018: International Conference on Concentrating Solar Power and Chemical Energy Systems
2–5 October 2018
Casablanca, Morocco
Research Article|
July 25 2019
Radiant emittance calculated by heat transfer analysis of a PTC receiver tested with vacuum versus measurement of an absorber sample using spectrophotometer Free
Rafael López-Martín;
Rafael López-Martín
a)
1
CIEMAT, Plataforma Solar de Almería; Ctra
. Senés km. 4.5, E04200, Tabernas, Almería (Spain
)a)Corresponding author: [email protected]
Search for other works by this author on:
Gema San Vicente;
Gema San Vicente
b)
2
CIEMAT, Plataforma Solar de Almería;
Avenida Complutense 40, E28040, Madrid (Spain
)
Search for other works by this author on:
Angel Morales;
Angel Morales
c)
2
CIEMAT, Plataforma Solar de Almería;
Avenida Complutense 40, E28040, Madrid (Spain
)
Search for other works by this author on:
Loreto Valenzuela
Loreto Valenzuela
d)
1
CIEMAT, Plataforma Solar de Almería; Ctra
. Senés km. 4.5, E04200, Tabernas, Almería (Spain
)
Search for other works by this author on:
Rafael López-Martín
1,a)
Gema San Vicente
2,b)
Angel Morales
2,c)
Loreto Valenzuela
1,d)
1
CIEMAT, Plataforma Solar de Almería; Ctra
. Senés km. 4.5, E04200, Tabernas, Almería (Spain
)
2
CIEMAT, Plataforma Solar de Almería;
Avenida Complutense 40, E28040, Madrid (Spain
)
a)Corresponding author: [email protected]
AIP Conf. Proc. 2126, 120010 (2019)
Citation
Rafael López-Martín, Gema San Vicente, Angel Morales, Loreto Valenzuela; Radiant emittance calculated by heat transfer analysis of a PTC receiver tested with vacuum versus measurement of an absorber sample using spectrophotometer. AIP Conf. Proc. 25 July 2019; 2126 (1): 120010. https://doi.org/10.1063/1.5117628
Download citation file:
Citing articles via
The implementation of reflective assessment using Gibbs’ reflective cycle in assessing students’ writing skill
Lala Nurlatifah, Pupung Purnawarman, et al.
Effect of coupling agent type on the self-cleaning and anti-reflective behaviour of advance nanocoating for PV panels application
Taha Tareq Mohammed, Hadia Kadhim Judran, et al.
Classification data mining with Laplacian Smoothing on Naïve Bayes method
Ananda P. Noto, Dewi R. S. Saputro
Related Content
Test bench HEATREC for heat loss measurement on solar receiver tubes
AIP Conf. Proc. (May 2016)
Heat losses model for standardized testing of receiver tubes for parabolic-troughs
AIP Conf. Proc. (November 2018)
Test loop for inter-connections of parabolic trough collectors
AIP Conf. Proc. (November 2018)
Harmonization of standards for parabolic trough collector testing in solar thermal power plants
AIP Conf. Proc. (June 2017)