In this research, we have developed a new chloride ion image sensor that displayed dynamic 2D images of the local concentration. The chloride sensitive membrane was prepared by casting a tetrahydrofuran solution containing a PVC membrane with manganese (III) porphyrin onto a CCD-type pH image sensor. The fabricated chloride ion sensor showed a near Nernst response at the concentration of 10−1-10−2 M and a super-Nernst response at the concentration of 10−2-10−3 M. In addition, the selectivity for anion ions did not follow the classical Hofmeister series. The selectivity for chloride ion was higher than those of perchlorate ion, bromide ion and iodide ion. These results were due to the complexation with the chloride ion peculiar to the metalloporphyrin.

1.
K.
Sawada
,
T.
Hattori
,
Japanese Journal of Applied Physics
,
57
,
1002A2
, (
2018
).
2.
M.
Futagawa
,
D.
Suzuki
,
R.
Otake
,
F.
Dasai
,
M.
Ishida
,
K.
Sawada
,
IEEE Transactions on Electron Devices
,
60
,
2634
2639
, (
2013
).
3.
T.
Hattori
,
Y.
Masaki
,
K.
Atsumi
,
R.
Kato
,
K.
Sawada
,
Analytical Sciences
,
26
,
1039
1044
, (
2010
).
4.
T.
Hattori
,
M.
Yoshimoto
,
S.
Mori
,
D.
Miyamoto
,
R.
Kato
,
K.
Sawada
,
Electroanalysis
,
24
,
114
120
, (
2012
).
5.
S.
Matsuba
,
R.
Kato
,
K.
Okumura
,
K.
Sawada
,
T.
Hattori
,
Analytical Sciences
,
34
,
553
558
, (
2018
).
6.
T.
Hattori
,
Y.
Tamamura
,
K.
Tokunaga
,
T.
Sakurai
,
R.
Kato
,
K.
Sawada
,
Analytical Chemistry
,
86
,
4196
4201
, (
2014
).
7.
H.
Fukuda
,
Y.
Ito
,
YAKUGAKU ZASSHI
,
118
,
340
341
, (
1998
).
8.
H.
Yashiro
,
K.
Tanno
,
Journal of The Surface Finishing Society of Japan
,
47
,
2
3
, (
1996
).
9.
F.
Hine
,
Journal of the Society of Materials Science, Japan
,
26
,
1124
1129
, (
1977
).
10.
S.
Yajima
,
H.
Ishigaki
,
Y.
Hori
,
R.
Takeaki
,
K.
Kimura
,
BUNSEKI KAGAKU
,
61
,
207
212
, (
2012
).
11.
A.
Radu
,
E.
Bakker
,
Chemia Analityczna (Warsaw)
,
50
,
71
83
, (
2005
).
12.
I. J.
Yoon
,
J. H.
Shin
,
I. R.
Paeng
,
H.
Nam
,
G. S.
Cha
,
K. –J.
Paeng
,
Analytica Chimica Acta
,
367
,
175
181
, (
1998
).
13.
R.
Paciorek
,
P.
Bieganowski
,
M.
Maj-Zurawska
,
Sensor and Actuator B
,
108
,
840
844
(
2005
).
14.
I. S.
Silva
,
E. M.
Richter
,
C. L.
Lago
,
I. G. R.
Gutz
,
A. A.
Tanaka
,
L.
Angnes
,
Talanta
,
67
,
651
657
, (
2005
)
15.
E. D.
Steinle
,
U.
Schaller
,
M. E.
Meyerhoff
,
Analytical Sciences
,
14
,
79
84
, (
1998
).
16.
D.
Ammann
,
M.
Huser
,
B.
Kräutler
,
B.
Rusterholz
,
P.
Schulthess
,
B.
Lindemann
,
E.
Halder
,
W.
Simon
,
Helvetica Chimica, Acta
,
69
,
849
854
, (
1986
).
17.
M.
Shamsipur
,
G.
Khayatian
,
S.
Tangestaninejad
,
Electroanalysis
,
11
,
1340
1344
, (
1999
).
18.
E.
Bakker
,
E.
Malinowska
,
R. D.
Schiller
,
M. E.
Meyerhoff
,
Talanta
,
41
,
881
, (
1994
).
19.
H-S.
Yim
,
C. E.
kibbey
,
S-C.
Ma
,
D. M.
Kliza
,
D.
Liu
,
S-B.
Park
,
C. E.
Torre
,
M. E.
Meyerhoff
,
Biosensors & Bioelectronics
,
8
,
7
11
, (
1993
).
20.
K. N.
Mikhelson
,
Ion-Selective Electrodes
, (
Springer
,
Berlin
,
2013
), pp.
38
42
.
This content is only available via PDF.