In the industrial world, the cooling tower is one of the tools used for cooling water circulation in industrial machinery. Inadequate cooling water can cause a machine, like a heat exchanger unit, to corrode or form scaling that will reduce effectiveness of the cooling tower system. This study aims to determine the effect of ozone performance and cooling tower water quality in a closed-type forced draft system - cross flow - indirect / closed. The method used in this research is to inject ozone 3gr / hr into the basin of the closed circuit system cooling tower and then conduct laboratory tests of AAS, Titrimetric, Gravimetric and Spectrophotometric. Value of evaporation loss showed 0:03 as the smallest value m³ / h and 0119 m³ / h as the largest. Ozone can be said to affect water quality in the closed circuit cooling tower system basin but ozone cannot be said to affect the performance for a period longer than 10 days.

1.
Ahmed
Taha
,
El-Sousy
K
,
Helles
R
,
Helles
S.
2006
.
Elimination of Remazole Blue-B by Advanced Oxidation Methods
.
Journal of Al Azhar University - Gaz.a
Vol.
8
,
55
64
.
2.
Alaton
,
IA
Balcioglu
,
DW
Bahnemann
.
2002
.
Advanced oxidation of a reactive dyebath effluent: Comparison of O3, H2O2 / UV-C and TiO2 / UV-A processes
.
Water Res.
36
.
1143
1154
. doi: .
3.
Indrawati
.
2008
.
Papers solution decolorize Remazol Brilliant Blue Using Ozone Electrolysis results
.
Semarang
:
Department of Chemical Engineering, Faculty of Engineering, University of Diponegoro
.
4.
Karamah
,
E. F.
,
S.
Bismo
, and
W. W.
Purwanto
.
2013
. “
Significance of Acoustic and Hydrodynamic Cavitations in Enhancing Ozone Mass Transfer
.”
Ozone: Science and Engineering
35
(
6
):
482
488
. doi:.
5.
Karamah
,
E. F.
,
R.
Ghaudenson
,
F.
Amalia
, and
S.
Bismo
.
2017
. “
Disinfection of Escherichia Coli Bacteria using Hybrid Method of Ozonation and Hydrodynamic Cavitation with Orifice Plate
.”.
AIP Conference Proceedings
Volume
1904
, Article number 020075, 3rd International Symposium on Applied Chemistry 2017, ISAC 2017. doi:.
6.
Ministry of Environment
.
2014
.
Regulation of the Minister of Environment of the Republic of Indonesia Number 5 of 2014 regarding Standard Wastewater. Jakarta
7.
Ministry of Industry
.
2015
.
Data for Small and Medium Enterprises Unit Batik in Indonesia
.
Jakarta
8.
McNicholas
,
PD
,
The Use of Ozone in Cooling Towers.
2002
.
9.
Sastrosudiro
,
BS
, et al,
Control Strategy of Solar Thermal Cooling System under the Indonesia Climate
. {
Journal
},
2016
, 2013.
10.
Sung
,
S.-K.
,
S.-H.
Suh
, and
D.-W.
Kim
,
Characteristics of cooling water fouling in a heat exchange system
.
Journal of mechanical science and technology
,
2008
.
22
(
8
): p.
1568
1575
.
11.
Program
,
NTD
,
Ozone Treatment for Cooling Towers.
1998
.
12.
Bott
,
TR
,
Fouling of heat exchangers
.
1995
:
Elsevier
.
This content is only available via PDF.