There is a common misconception that all central systems are only operating in full-load conditions where in fact, most central systems are have the control system that can adjust the operating condition with the cooling loads. Customers tend to choose the air conditioning systems based only on full-load ratings despite a system may have different ratings on different load profiles. These differences can result in more expensive annual energy cost. The goal of this research is to develop an equation to provide customers with the part-load efficiency ratings of central air conditioning system (chiller) as an addition to full-load efficiency ratings provided by air conditioner companies. Non-standard Part Load Value (NPLV) is an equation to obtain part-load efficiency of a system which coefficients vary with location of interest. In this paper, NPLV for city of Jakarta, Bandung, Pontianak, Kupang, and Palembang were determined by Degree-Hours Method and Radiant Time Series Method. The results are compared and discussed.
Skip Nav Destination
Article navigation
25 January 2019
THE 10TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2018): Smart City: Advances in Thermofluid Technology in Tropical Urban Development
16–17 November 2018
Bali, Indonesia
Research Article|
January 25 2019
Determination of non-standard part-load value coefficients for chiller in several cities of Indonesia
Ari D. Pasek;
Ari D. Pasek
a)
1
Faculty of Mechanical and Aerospace Engineering – Institute Technology of Bandung
, Jl. Ganesha No.10 Taman Sari, Bandung 41032 Jawa Barat, Indonesia
a)Corresponding author: aripasek@gmail.com
Search for other works by this author on:
Haekal Adityo;
Haekal Adityo
b)
1
Faculty of Mechanical and Aerospace Engineering – Institute Technology of Bandung
, Jl. Ganesha No.10 Taman Sari, Bandung 41032 Jawa Barat, Indonesia
Search for other works by this author on:
Ruben Asido Mauliate
Ruben Asido Mauliate
c)
1
Faculty of Mechanical and Aerospace Engineering – Institute Technology of Bandung
, Jl. Ganesha No.10 Taman Sari, Bandung 41032 Jawa Barat, Indonesia
Search for other works by this author on:
AIP Conf. Proc. 2062, 020034 (2019)
Citation
Ari D. Pasek, Haekal Adityo, Ruben Asido Mauliate; Determination of non-standard part-load value coefficients for chiller in several cities of Indonesia. AIP Conf. Proc. 25 January 2019; 2062 (1): 020034. https://doi.org/10.1063/1.5086581
Download citation file:
730
Views
Citing articles via
Related Content
Cost benefit analysis and energy savings of using compression and absorption chillers for air conditioners in hot and humid climates
AIP Conference Proceedings (June 2012)
Exploratory analysis of water quality in the settlement area of Pontianak City
AIP Conference Proceedings (September 2020)
The contributions of the principals’ managerial skills and organizational climate towards productive teacher’s professionalism of vocational high schools in Kupang
AIP Conference Proceedings (October 2016)
Thermodynamic modeling of reciprocating chillers
Journal of Applied Physics (March 1994)
Chiller compressor sound emission analysis
J Acoust Soc Am (April 2022)