This work reports on the recent activities carried out by the Detector and Instrumentation Laboratory of Elettra Sincrotrone Trieste. Since both the Elettra synchrotron and the Fermi free electron laser are generating photons in the low to medium x-ray energy range from some eV to tenths of keV the activities of the detector and instrumentation laboratory focuses on spectroscopic and imaging photon detectors, which feature high quantum efficiency from below the carbon edge and are operated also in UHV environments. Special focus will be drawn on custom made monolithic and multi element silicon drift detectors for the Twinmic and the XRF beam line at Elettra. Regarding low energy imaging detectors the PERCIVAL CMOS (‘Pixelated Energy Resolving CMOS Imager, Versatile and Large’) will be discussed which is currently being developed by a collaboration of DESY, RAL, Elettra, PAL and DLS to address the need for this type of detectors for free electron lasers in the soft X-ray regime. The majorities of Elettra’s soft x-ray beam lines are employing fast and spatially resolving electron detectors and their associated readout electronics, which have been developed in-house and have been tailored to the specific needs of the respective beam line. In addition devices for in situ beam diagnostics and dose monitoring for synchrotron radiation and FEL beams have been developed and are operated on a daily basis. Moreover, some recent results in basic research on room temperature semiconductors will be discussed. It is noteworthy that Elettra Sincrotrone Trieste through its Industrial Liaison Office commercializes many of these devices and the associated read-out electronics. In this presentation an overview of these devices and their application to specific scientific applications will be given and in view of upgrade programs future directions will be discussed.

1.
R.H.
Menk
 et al,
HiResMon: A fast high resolution beam position monitor for medium and hard X-rays
,
AIP Conference Proceedings
879
,
1109
, ,
2007
.
2.
D.
Dreossi
 et al,
The mammography project at the SYRMEP beamline
,
European Journal of Radiology
68S
,
S58
S62
,
2008
.
3.
L.
Fröhlich
 et al,
The machine Protection System of FERMI
,
Proceedings of the FEL 2010
,
667
670
,
Malmö, Sweden
,
2010
.
4.
J.
Morse
, et al,
Diamond X-ray beam-position monitoring using signal readout at the synchrotron radi of requency
Journal, Synchrotron Radiation
17
,
456
,
2010
.
5.
A.
De Sio
 et al,
X-ray micro beam analysis of the photoresponse of an enlarged CVD diamond single crystal
.
Diamond and Related Materials
,
34
,
36
40
,
2013
.
9.
M.
Lonza
 et al,
Design of a fast Global Orbit Feedback System for the Elettra Storage Ring
,
Proceedings of the 10th ICALEPCS
,
Geneva, Switzerland
, PO2.011-2,
2005
.
10.
M.
Antonelli
 et al,
Bunch by bunch beam monitoring in 3rd and 4th generation light sources by means of single crystal diamond detectors and quantum well devices (Vol. 8504
).
Presented at the Proceedings of SPIE - The International Society for Optical Engineering
,
2012
.
11.
G.
Cautero
 et al,
A two-dimensional detector for pump-and-probe and time resolved experiments
,
Nuclear Instruments and Methods in Physics Research
, vol.
595
(
2
) pp.
447
459
,
2008
.
12.
A.
Gianoncelli
 et al,
Current status of the TwinMic beamline at Elettra: A soft X-ray transmission and emission microscopy station
,
Journal of Synchrotron radiation
, vol.
23
-
6
,
2016
.
13.
A.
Di Cicco
 et al,
Novel XAFS capabilities at Elettra synchrotron light source
,
Journal of Physics: Conference Series
190
,
2009
.
14.
J.
Bufon
 et al,
A new large solid angle multi-element silicon drift detector system for low energy X-ray fluorescence spectroscopy
,
Journal of Instrumentation
13
(
03
),
C03032
,
2018
.
15.
C.B.
Wunderer
 et al,
The PERCIVAL soft X-ray imager
,
Journal of Instrumentation
,
10
(
02
),
C02008
C02008
.,
2015
.
16.
A.
Pilotti
 et al,
An Improved Nonlocal History-Dependent Model for Gain and Noise in Avalanche Photodiodes Based on Energy Balance Equation
,
IEEE Transactions on Electron Devices
vol.
65
, no.
5
,
2018
.
This content is only available via PDF.