In order to ensure rapid and successful operation of the high performance beamline instruments and optics, a test beamline (09B) has been built at Shanghai Synchrotron Radiation Facility (SSRF) for the at-wavelength measurements. The bending magnet is employed as the light source, and the acceptance angle is2.5×0.3mrad2. The beamline optical elements: 1D compound refractive lens, water cooling double crystal monochromator, toroidal mirror and other optical components could be switched in the vacuum for different operational modes. A KB mirror system is employed to micron focus at the experimental station, and the beamline provides 100mm spot size in horizontal direction. The beamline photon energy range is 4-50keV, energy resolution is 5x10−4@10keV and photon flux is 3x1011phs/s@300mA. Variety instruments and detectors have been provided for the diffraction, spectroscopy, imaging and other at-wavelength measurement. Details of the beamline optical design and energy resolution measuring performance of the high energy double Laue crystal monochromator and water cooling double crystal monochromator are also presented in this paper.
Skip Nav Destination
Article navigation
15 January 2019
PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION – SRI2018
11–15 June 2018
Taipei, Taiwan
Research Article|
January 15 2019
The design of the test beamline at SSRF
Zhongliang Li;
Zhongliang Li
a)
1
Shanghai Institute of Applied Physics, Chinese Academy of Sciences (CAS)
, Shanghai Synchrotron Radiation Facility (SSRF), 239 Zhangheng Road, Pudong New District, Shanghai, 201203, CHINA
a)Corresponding author: lizhongliang@sinap.ac.cn
Search for other works by this author on:
Yichen Fan;
Yichen Fan
1
Shanghai Institute of Applied Physics, Chinese Academy of Sciences (CAS)
, Shanghai Synchrotron Radiation Facility (SSRF), 239 Zhangheng Road, Pudong New District, Shanghai, 201203, CHINA
Search for other works by this author on:
Lian Xue;
Lian Xue
1
Shanghai Institute of Applied Physics, Chinese Academy of Sciences (CAS)
, Shanghai Synchrotron Radiation Facility (SSRF), 239 Zhangheng Road, Pudong New District, Shanghai, 201203, CHINA
Search for other works by this author on:
Zengyan Zhang;
Zengyan Zhang
1
Shanghai Institute of Applied Physics, Chinese Academy of Sciences (CAS)
, Shanghai Synchrotron Radiation Facility (SSRF), 239 Zhangheng Road, Pudong New District, Shanghai, 201203, CHINA
Search for other works by this author on:
Jie Wang
Jie Wang
b)
1
Shanghai Institute of Applied Physics, Chinese Academy of Sciences (CAS)
, Shanghai Synchrotron Radiation Facility (SSRF), 239 Zhangheng Road, Pudong New District, Shanghai, 201203, CHINA
b)Corresponding author: wangjie@sinap.ac.cn
Search for other works by this author on:
a)Corresponding author: lizhongliang@sinap.ac.cn
b)Corresponding author: wangjie@sinap.ac.cn
AIP Conf. Proc. 2054, 060040 (2019)
Citation
Zhongliang Li, Yichen Fan, Lian Xue, Zengyan Zhang, Jie Wang; The design of the test beamline at SSRF. AIP Conf. Proc. 15 January 2019; 2054 (1): 060040. https://doi.org/10.1063/1.5084671
Download citation file:
Citing articles via
Related Content
X‐ray Microscopy Beamlines at SSRF—Present Status and Future Plan
AIP Conference Proceedings (September 2011)
A high-performance bending magnet beamline (BL02B) at the SSRF
AIP Conference Proceedings (January 2019)
SSRF Beamline Control System
AIP Conference Proceedings (June 2010)
Current Status of the SSRF Project
AIP Conference Proceedings (January 2007)
A level-2 biosafety beamline for macromolecular crystallography at SSRF
AIP Conference Proceedings (January 2019)