ALBA is a third generation 3-GeV synchrotron radiation facility built near Barcelona servicing worldwide academic and industrial users since 2012. It currently hosts eight operating beamlines, including one dedicated to Macromolecular Crystallography (MX), BL13-XALOC. Current expansion plans of the facility include a specific microfocus MX beamline, BL06-XAIRA, now in design stage, which will complement the existing BL13-XALOC MX beamline. The aim of XAIRA is to provide a stable, high-flux beam of 1×1 μmm2 FWHM (3×1 μmm2 full beam) at 1 Å photon wavelength and reach ∼4 keV in the low limit of the energy range. Here we present the current plans for the photon source and the optical design of the XAIRA beamline, as well as the some preliminary ideas on the end station.

1.
J.
Juanhuix
 et al, “
Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron
,”
J. Synchrotron Radiat.
, vol.
21
, no.
4
, pp.
679
689
,
2014
.
2.
J. P.
Rose
,
B. C.
Wang
, and
M. S.
Weiss
, “
Native SAD is maturing
,”
IUCrJ
, vol.
2
, no.
20
, pp.
431
440
,
2015
.
3.
Q.
Liu
and
W. A.
Hendrickson
, “
Crystallographic phasing from weak anomalous signals
,”
Curr. Opin. Struct. Biol.
, Vol.
34
,
2015
.
4.
R. L.
Owen
,
J.
Juanhuix
, and
M.
Fuchs
, “
Current advances in synchrotron radiation instrumentation for MX experiments
,”
Arch. Biochem. Biophys.
, vol.
602
, pp.
21
31
,
2016
.
5.
J.
Campmany
,
J.
Nicolás
,
J.
Juanhuix
,
J.
Marcos
, and
V.
Massana
, “
A general view of IDs to be installed at ALBA for second and third phase beam-lines
,” in
AIP Conference Proceedings
,
2016
, vol.
1741
.
6.
J.
Nicolas
,
N.
González
,
J.
González
,
C.
Ruget
,
J.
Juanhuix
, and
C.
Colldelram
, “
Adaptive optics bender with sub-nanometer correction and stability
,” in
These proceedings.
7.
J.
Nicolas
,
A.
Barla
, and
J.
Juanhuix
, “
The Alba ray tracing code: ART
,” in
Proceedings of SPIE - The International Society for Optical Engineering
,
2013
, vol.
8848
.