A soft x-ray reflectivity beamline covering 100 eV – 1500 eV photon energy range is designed, fabricated and commissioned at bending magnet port of Indian synchrotron radiation facility Indus-2 to cater thin film/ multilayer users to analyze structural and optical behavior. The experimental station is designed to test x-ray mirrors upto ∼300 mm length in the soft x-ray region. The beamline provides monochromatic photons using a constant deviation angle variable line spacing plane grating monochromator with Hettrick type optics. Pre and post focusing toroidal mirrors are used to collect and deliver the beam from source to the experimental station. A reflectometer system comprising of a θ-2θ goniometer capable to hold big size samples upto 300 mm length and 5 kg weight is employed for performing various scans for reflectivity experiments. The goniometer is set in a vertical reflection geometry. The sample stage is electrically isolated from the rest of the system to enable one to record total electron yield signal for soft x-ray absorption measurements. This paper describes the beamline and its capabilities with examples of measured results.
Skip Nav Destination
Article navigation
15 January 2019
PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION – SRI2018
11–15 June 2018
Taipei, Taiwan
Research Article|
January 15 2019
A soft x-ray reflectivity beamline for 100-1500 eV energy range at Indus-2 synchrotron radiation source
Mohammed H. Modi;
Mohammed H. Modi
a)
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
2
Homi Bhabha National Institute
, Anushakti Nagar, Mumbai 400094, India
a)Corresponding author: modimh@rrcat.gov.in
Search for other works by this author on:
R. K. Gupta;
R. K. Gupta
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
S. R. Kane;
S. R. Kane
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
V. Prasad;
V. Prasad
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
C. K. Garg;
C. K. Garg
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
P. Yadav;
P. Yadav
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
V. K. Raghuvanshi;
V. K. Raghuvanshi
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
Search for other works by this author on:
Amol Singh;
Amol Singh
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
3
National Synchrotron Radiation Research Center
, Hsinchu 30076, Taiwan
Search for other works by this author on:
Mangalika Sinha
Mangalika Sinha
1
Raja Ramanna Centre for Advanced Technology
, Indore 452 013 India
2
Homi Bhabha National Institute
, Anushakti Nagar, Mumbai 400094, India
Search for other works by this author on:
a)Corresponding author: modimh@rrcat.gov.in
AIP Conf. Proc. 2054, 060022 (2019)
Citation
Mohammed H. Modi, R. K. Gupta, S. R. Kane, V. Prasad, C. K. Garg, P. Yadav, V. K. Raghuvanshi, Amol Singh, Mangalika Sinha; A soft x-ray reflectivity beamline for 100-1500 eV energy range at Indus-2 synchrotron radiation source. AIP Conf. Proc. 15 January 2019; 2054 (1): 060022. https://doi.org/10.1063/1.5084653
Download citation file:
Citing articles via
Related Content
Optical Design of VLS‐PGM Soft X‐Ray Beamline on Indus‐2
AIP Conference Proceedings (June 2010)
X-ray multilayer optics for Indus synchrotrons application
AIP Conference Proceedings (June 2015)
Indus synchrotron source: A national facility
AIP Conference Proceedings (June 2012)
Status of The Indian SRS Indus‐2
AIP Conference Proceedings (July 2009)
Beamlines on Indus‐1 and Indus‐2 for X‐ray Multilayer Optics and Micro Fabrication Research
AIP Conference Proceedings (January 2007)