The Coherence branch of the I13 beamline in Diamond Light Source is specialized in reciprocal space imaging using Ptychography and Bragg CDT techniques. The experimental hutch is 220 m from the synchrotron source, providing the x-ray beam with intrinsic high spatial coherence. The capacious hutch allows variable sample-detector distance up to l4.5 m. This, in combination with the use of the large area photon counting detector Excalibur, enables fields of view as large as 500 μm, resolution down to tens of nanometers and acquisition rate in excess of l00 Hz. Recently the ptychography scan has been combined to the x-ray fluorescence scan to simultaneously access the chemical and structural information of the sample.
REFERENCES
1.
D. J.
Batey
, T. B.
Edo
, C.
Rau
, U.
Wagner
, Z.
Pesic
, T.
Waigh
, J.
Rodenburg
, Reciprocal-space up-sampling from real-space oversampling in x-ray ptychography
, Physical Review A
89
(4
) (2014
).2.
M.
Newton
, A.
Parsons
, U.
Wagner
, C.
Rau
, Coherent x-ray diffraction imaging of photo-induced structural changes in BiFeO3 nanocrystals
, New Journal 0f Physics
18
(2016
).3.
P.
Martin
, S.
Cipiccia
, D.
Batey
, K.
Hallam
, T. A. X.
Yang
, C.
Jones
, Y.
Satou
, T.
Griffiths
, C.
Rau
, D.
Richards
, T.
Scott
, Internal analysis of a Fukushima-derived particle using high-resolution synchrotron techniques
, submitted to Environmental Science & Technology
(2018
)4.
D.
Batey
, Ptychographic Imaging of Mixed States
, PhD thesis, University of Sheffield
(2014
). http://etheses.whiterose.ac.uk/8524/5.
N.
Tartoni
, P.
Gibbons
, E.
Gimenez
, T.
Horswell
, J.
Marchal
, U.
Pedersen
, Z.
Pesic
, R.
Plackett
, C.
Rau
, R.
Somayaji
, J.
Spiers
, J.
Thompson
, B.
Willis
, C.
Angelsen
, P.
Booker
, S.
Burge
, J.
Lipp
, T.
Nicholls
, S.
Taghavi
, M.
Thorpe
and G.
Dennis
, EXCALIBUR: a Three Million Pixels Photon Counting Area Detector for Coherent Diffraction Imaging Based on the Medipix3 ASIC
, Nuclear Science Symposium and Medical Tmaging Conference Record(NSS/MTC)
, (2012
) N2-3
530
6.
D. A.
Sherrell
, A. J.
Foster
, L.
Hudson
, B.
Nutter
, J.
O’Hea
, S.
Nelson
, O.
Pare-Labrosse
, S.
Oghbaey
, R. J. D.
Miller
and R. L.
Owen
, A modular and compact portable mini-endstation for high-precision, high-speed fixed target serial crystallography at FEL and synchrotron source
, J. Synchrotron Rad.
(2015
). 22
, 1372
–1378
7.
R. L.
Owen
, D.
Axford
, D. A.
Sherrell
, A.
Kuo
, O. P.
Ernst
, E.C.
Schulz
, R. J. D.
Miller
, and H. M.
Mueller-Werkmeister
, Low-dose fixed-target serial synchrotron crystallography
, Acta Cryst.
(2017
), D73
, 373
–378
8.
S.
Cipiccia
, D.
Batey
, X.
Shi
, P.
Martin
, T.
Scott
, C.
Rau
, An Iterative algorithm for self-absorption correction in 3D fluorescence imaging
, in preparation.© 2019 Author(s).
2019
Author(s)