Over the past years the Brazilian Synchrotron Light Laboratory has massively invested on strategic areas to support the design, construction and operation of its new beamlines for SIRIUS, a 4th generation light-source with first photon-beam foreseen for this year. The extent of these developments ranges from basic beamlines’ infrastructure systems such as utilities and radiation enclosures, undergoing precision mechanics, mechatronics, metrology, to new detectors and advanced data processing schemes. This contribution will offer a brief status and overview of the developed and proposed solutions for these areas as well as perspectives for the installation of the first beamlines.
REFERENCES
1.
A. R. D.
Rodrigues
et al., “SIRIUS Status Report”, in Proc. of IPAC 2018
, Vancouver, Canada
, May 2018
, paper THXGBD4, to be published.2.
L. N. P.
Vilela
et al., “Advances in the SIRIUS Delta-Type Undulator Project”, in Proc. of IPAC
2018
, Vancouver, Canada
, May 2018, paper TUPMK003, to be published.3.
L. M.
Volpe
et al., “High Heat-load Front-ends for SIRIUS”, in Proc. of MEDSI
2016
, Barcelona, Spain
, Jun. 2016, pp. 324
–326
.4.
L.
Sanfelici
et al., “Carbon-Steel/Polyethylene Radiation Enclosures for the SIRIUS Beamlines”, in Proc. of MEDSI
2016
, Barcelona, Spain
, Jun. 2016, pp. 223
–225
.5.
H. G. P.
Oliveira
et al., “The LNLS Metrology Building”, in Proc. of MEDSI
2016
, Barcelona, Spain
, Jun. 2016.6.
H. G. P.
Oliveira
et al., “The LNLS Metrology Building - Environmental Control Results”, in Proc. of MEDSI
2018
, Paris, France
, Jun. 2018, paper TUPH43, to be published.7.
R. R.
Geraldes
et al., “The new high-dynamic DCM for SIRIUS”, in Proc. of MEDSI
, Barcelona, Spain
, Sep. 2016, pp. 141
–146
.8.
R. R.
Geraldes
et al., “Offline Results of the New High-Dynamic DCM for SIRIUS”, in Proc. of MEDSI
2018
, Paris, France
, Jun. 2018, paper WEOAMA01, to be published.9.
R. R.
Geraldes
et al., “The Design of Exactly-constrained X-ray Mirror Systems for SIRIUS”, in Proc. of MEDSI
2018
, Paris, France
, Jun. 2018, paper WEOAMA04, to be published.10.
B. C.
Meyer
, M. B.
Silva
, "A New Optics Metrology Laboratory at CNPEM: Metrology Capabilities, Performance, and Future Plans
", in Proc. SPIE
Vol. 10385
, 103850C
(2017
).11.
B. C.
Meyer
, M. B.
Silva
and R.
Oliveira
, “Commissioning of the LNLS Long Trace Profiler (LTP VI)”, in Proc. of IXWM
2018
, Hsinchu, Taiwan
, Jun. 2018, to be published.12.
Moraes
, M.
et al., “A Control Architecture Proposal for SIRIUS Beamlines”, in Proc. of ICALEPCS
2017
, Barcelona, Spain
, Oct. 2017, pp. 1947
–1952
.13.
Ruiz
, M.
et al., “IRIO Technology: Developing Applications for Advanced DAQ Systems Using FPGAs
”, Proc. of IEEE-NPSS Real Time Conference
2016
, doi: .14.
Slepicka
, H.
et al. Python for Synchrotrons
. Journal of Synchrotron Radiation
, v. 22
, p. 1182
–1189
, 2015.15.
Bezerra
Beniz
, D., “Customization of MXCuBE 2 (Qt4) Using EPICS for a Brazilian Synchrotron Beamline”, in Proc. of ICALEPCS
2017
, Barcelona, Spain
, Oct. 2017
, pp. 1923
–1925
.16.
CERN Medipix3 Collaboration (
2018
, June 13). Retrieved from: https://medipix.web.cern.ch/collaboration/medipix3-collaboration.17.
X.
Wu
et al. Study of edgeless radiation detector with 3D spatial mapping technique.
2014 JINST 9 C04004.18.
Miqueles
, E. X.
, Koshev
, N.
, Helou
, E. S.
, "A Backprojection Slice Theorem for Tomographic Reconstruction
", IEEE Transactions on Image Processing
, Feb. 2018
, Vol. 27
(2
), pp. 894
–906
.
This content is only available via PDF.
© 2019 Author(s).
2019
Author(s)