The article describes design of an experimental equipment for an electrical resistance tomography (ERT) of an air-water bubble multiphase flow. It reuses most of a circuit from a previous PIV experiment, with an exception of a measurement segment and adjacent pipes. The core components are two electrode rings each with 16 stainless steel electrodes smoothly embedded to its walls. The design is made modular, so it is possible to easily swap or modify its parts in case of need.
REFERENCES
1.
M.
Wang
, Industrial Tomography Systems and Applications, Woodhead Publishing
, 2015
, ISBN 978-1-78242-118-4.2.
F.
Dickin
, M.
Wang
, “Electrical Resistance Tomography for Process Applications
” in Meas. Sci. Technol.
7
, IOP Publishing Ltd, 1996
, pp. 247
–260
3.
p2+ Electrical Resistance Tomography System - User’s Manual
, Industrial Tomography Systems Plc.
, 2014
4.
v5r Electrical Resistance Tomography System - User’s Manual
, Industrial Tomography Systems Plc.
, 2015
This content is only available via PDF.
© 2018 Author(s).
2018