To protect the acoustical environment of auditorium in performing place, this paper mainly focusses on the emission noise measurement method of stage machinery. For the high noise and frequently-used equipment during the performance, the measurement equipment, environment and condition, detection position, evaluation parameter, tested object and the running requirement are all studied and discussed. In particular, the suitable test point and load demand is analyzed through the simulation of EASE software and the noise measurement under laboratory environment. Our research aims to provide the basic work for developing the draft standard for stage machinery noise, which has certain application value to improve the audio-visual effects and control the noise pollution for modern theatre.

1.
X. D.
Zhu
, “Research on Acoustic Design Development of Performance Building,” Master’s thesis,
Tsinghua University
,
2012
.
2.
GB/T 50356-2005,
Code for architectural acoustical design of theatre, cinema and multi-use auditorium
.
3.
WH/T 27-2007,
Mechanical Equipment on Stages-Acceptance Test Procedures.
4.
Q
Xu
, “
Development of National and International stage machinery
,” in
Art Science and Technology
,
2001
, No.
1
, pp.
8
21
.
5.
S.Q
Ma
and
C
Li
,
The Stage machinery
(
China Machine Press
,
Beijing
,
1992
), pp.
26
28
.
6.
Y. M.
Song
, “
Architectural Acoustics Design for Cultural Tourism Theatre
,” in
the 2017 National academic Conference on Acoustic Design, noise and Vibration Control Engineering
, May 16-18,
2017
.
7.
J. J.
Zhang
and
Z. Q.
Rao
, “
Noise Inspection of Stage Machinery for National Center for the Performing Arts
,” in
Entertainment technology
,
2010
, No.
11
, pp.
31
37
.