Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

1.
A. S.
Go
,
D
Mozaffarian
,
VL
Roger
,
EJ
Benjamin
,
JD
Berry
,
WB
Borden
,
DM
Bravata
,
S
Dai
,
ES
Ford
,
CS
Fox
,
S
Franco
,
HJ
Fullerton
,
C
Gillespie
,
SM
Hailpern
,
JA
Heit
,
VJ
Howard
,
MD
Huffman
,
BM
Kissela
,
SJ
Kittner
,
DT
Lackland
,
JH
Lichtman
,
LD
Lisabeth
,
D
Magid
,
GM
Marcus
,
A
Marelli
,
DB
Machtar
,
DK
McGuire
,
ER
Mohler
,
CS
Moy
,
ME
Mussolino
,
G
Nichol
,
NP
Paynter
,
PJ
Schreiner
,
PD
Sorlie
,
J
Stein
,
TN
Turan
,
SS
Virani
,
ND
Wong
,
D
Woo
,
MB
Turner
,
American Heart Association Statistics Committee and Stroke Statistics Subcommittee, Circulation
127
,
143
152
(
2013
).
2.
J. J.
Oresko
,
H
Duschl
,
AC
Cheng
,
IEEE Trans. Inf. Technol. Biomed.
14
,
734
740
(
2010
).
3.
A. T.
Hinman
,
B. T.
Engel
, and
A. F.
Bickford
,
Am. Heart J.
63
,
663
668
(
1962
).
4.
R.
Weitgasser
,
B.
Gappmayer
, and
M.
Pichler
,
Clin. Chem.
45
,
1821
1825
(
1999
).
5.
M. A.
Agung
and
Basari
,
AIP Conf. Proc.
1817
,
40015
(
2017
).
6.
S.
Kara
,
S.
Kemaloğlu
, and
Ş.
Kirbaş
,
J. Med. Syst.
30
,
205
209
(
2006
).
7.
JYE Tech Ltd
., “
Users Manual DSO138
.” [Online]. Available: http://www.jyetech.com/Products/LcdScope/e138.php. [Accessed: 26-Mar-2017].
8.
M. S.
Steyaert
and
W. M.
Sansen
,
IEEE J. Solid-State Circuits
22
,
1162
1168
(
1987
).
9.
R. R.
Harrison
, “
A versatile integrated circuit for the acquisition of biopotentials
,” in
CICC’07. IEEE
,
2007
, pp.
115
122
.
10.
M.
Saint-Laurent
and
M.
Swaminathan
,
IEEE Trans. Adv. Packag.
27
,
135
144
(
2004
).
This content is only available via PDF.